Performance of Compressor of XJ-41-V Turbojet Engine. 3; Compressor Static-Pressure Rise at Equivalent Compressor Speeds of 5000, 7000, 8000, and 9000 rpm

At the request of the Air Materiel Command, Army Air Forces, an investigation is being conducted at the NACA Cleveland laboratory to determine the performance characteristics of the XJ-41-V turbojet-engine compressor. The static-pressure variation in the direction of flow through the compressor was presented in reference 1 for an equivalent speed of 8000 rpm. An analysis of these pressure indicated that the maximum-flow limitation of the compressor was caused by separation, which reduced the effective flow area at the vaned-collector entrance. As a result of this analysis, the flow area at the vaned-collector entrance was increased to obtain larger mass flows. The area increase was obtained by cutting back the entrance edges of the collector vanes, which resulted in an increased vaneless-diffuser radius. Comparative performance of the original and revised compressors at an equivalent speed of 8000 rpm is presented. The static-pressure rise through the compressor, determined from static pressures at the impeller entrance and the vaned-collector exit, is also presented together with the compressor adiabatic efficiency and the mass flow over an equivalent speed range from 5000 to 9000 rpm. These static-pressure data are presented for the purpose of correlating the compressor performance with the turbojet-engine performance.