Use of Overoxidised Polypyrrole as a Chromium(VI) Sensor

Abstract A new Cr(VI) sensor has been developed in this work. The sensor was prepared by coating a layer of polypyrrole on a gold electrode and then oxidising the polymer film by scanning to anodic potentials. This pretreatment procedure decreased the background current usually associated with the electroactivity of the polymer. Determination of Cr(VI) using this sensor was investigated. It was found that Cr(VI) was preconcentrated upon application of an anodic potential (+0.80 V). Detection limits of the order of 10 ppb Cr(VI) were obtained.

[1]  M. Freund,et al.  Effect of electrode substrate on the morphology and selectivity of overoxidized polypyrrole films. , 1991, Analytical chemistry.

[2]  M. Freund,et al.  Anion-excluding polypyrrole films. , 1991, Talanta.

[3]  J. Koropchak,et al.  Thermospray Enhanced Inductively Coupled Plasma Atomic Emission Spectroscopy Detection for Liquid Chromatography , 1990 .

[4]  Gordon G. Wallace,et al.  Selective determination of Cr(VI) oxyanions using a poly‐3‐methylthiophene‐modified electrode , 1989 .

[5]  W. Frankenberger,et al.  Single-column ion-chromatographic determination of chromium(VI) in aqueous soil and sludge extracts. , 1989, Talanta: The International Journal of Pure and Applied Analytical Chemistry.

[6]  F. Saleh,et al.  Ion Chromatography of Soluble Cr(III) and Cr(VI) , 1989 .

[7]  M. Zagorska,et al.  Overoxidation in conducting polymers , 1989 .

[8]  J. K. Hardy,et al.  Method for the determination of chromium (VI) as chromium (VI)-dibenzyidithiocarbamate , 1989 .

[9]  Y. Suzuki,et al.  Anion-exchange high-performance liquid chromatographic determination of ascorbic acid and hexavalent chromium in rat lung preparations after treatment with sodium chromate in vitro and in vivo. , 1989, Journal of chromatography.

[10]  Yongfang Li,et al.  Studies on the chemical compensation of conducting polypyrrole by NaOH solution , 1988 .

[11]  T. Chao,et al.  A study of polypyrrole synthesized with oxidative transition metal ions , 1988 .

[12]  P. Kulesza,et al.  Preconcetration and voltammetric behavior of chromium(VI) at Pt electrodes modified with poly(4-vinylpyridine) , 1983 .

[13]  P. Kulesza,et al.  Stripping voltammetry of chromium(VI) at a poly(4-vinvlpyridine)-coated platium electrode , 1983 .

[14]  D. C. Johnson,et al.  Chromatographic determination of chromium(VI) with coulometric detection based on the electrocatalysis by adsorbed iodine of the reduction at platinum electrodes in acidic solutions , 1978 .

[15]  F. Oehme Toxicity of heavy metals in the environment , 1978 .

[16]  T. R. Mueller,et al.  The determination of chromium(VI) in natural waters by differential pulse polarography. , 1975, Analytica chimica acta.