Large eddy simulation of turbulent flow and mass transfer in far-field of swirl diffusers

Herein, the turbulent flow structures, mass transfer and ventilations characteristics in the far-field of swirl diffusers are numerically studied at different swirl angles (45° ≤ α ≤ 65°). The results are obtained via a 2nd order finite difference scheme and large eddy simulation (LES) with the dynamic Smagorinsky procedure in sub-grid-scale modeling. Accordingly, the instantaneous and average velocity distributions, transient evolution of the mass transfer, and the overall and local air qualities are investigated in this paper. Also, three main secondary-flow structures are observed in the simulations: a bubble vortex breakdown (α ≤ 45°), a toroidal recirculation zone on the top corners of the room (α ≤ 50°), and a toroidal central recirculation zone attached to the floor (far-field). However, the jet type alternates from the open swirl to Coanda jet in the range 50° ≤ α ≤ 55°, where both types exhibit enhanced ventilation characteristics. In this range, the open swirl jet with the highest swirl angle is more effective in discharging the aged air and also shows improved local air quality in the central region of the room (at α = 50°). On the other hand, the Coanda jet with the least swirl angle is more effective in mixing the fresh air throughout the domain and improves the average air quality (at α = 55°).

[1]  D. Lilly,et al.  A proposed modification of the Germano subgrid‐scale closure method , 1992 .

[2]  O. Vasilyev,et al.  Fully conservative finite difference scheme in cylindrical coordinates for incompressible flow simulations , 2004 .

[3]  S. Harthug,et al.  [Infection control in hospitals]. , 2002, Tidsskrift for den Norske laegeforening : tidsskrift for praktisk medicin, ny raekke.

[4]  Jerry Westerweel,et al.  Fully developed turbulent pipe flow: a comparison between direct numerical simulation and experiment , 1994, Journal of Fluid Mechanics.

[5]  Jean-Marie Aerts,et al.  Modelling mass transfer phenomena and quantification of ventilation performance in a full scale installation , 2005 .

[6]  Shih-Cheng Hu,et al.  Airflow characteristics in the outlet region of a vortex room air diffuser , 2003 .

[7]  Jiyuan Tu,et al.  On the numerical study of contaminant particle concentration in indoor airflow , 2006 .

[8]  Xudong Yang,et al.  Total air age: an extension of the air age concept , 2003 .

[10]  T. O’Doherty,et al.  Vortex breakdown: a review , 2001 .

[11]  Behzad Sajadi,et al.  Numerical investigation of the swirling air diffuser: Parametric study and optimization , 2011 .

[12]  Constantinos A. Balaras,et al.  HVAC and indoor thermal conditions in hospital operating rooms , 2007 .

[13]  Ramadan Bassiouny,et al.  Studying the features of air flow induced by a room ceiling-fan , 2011 .

[14]  Bin Zhao,et al.  Prediction of transient contaminant dispersion and ventilation performance using the concept of accessibility , 2004 .

[15]  P. Moin,et al.  A dynamic subgrid‐scale eddy viscosity model , 1990 .

[16]  T. Taylor,et al.  Computational methods for fluid flow , 1982 .

[17]  Angui Li,et al.  Fire-induced smoke control via hybrid ventilation in a huge transit terminal subway station , 2012 .

[18]  P. Moin,et al.  Large-eddy simulation of turbulent confined coannular jets , 1996, Journal of Fluid Mechanics.

[19]  Derek Dunn-Rankin,et al.  Using numerical simulation to predict ventilation efficiency in a model room , 1998 .

[20]  Guohui Gan,et al.  Effective depth of fresh air distribution in rooms with single-sided natural ventilation , 2000 .