Compressive strength of 24S-T aluminum-alloy flat panels with longitudinal formed hat-section stiffeners

Results are presented for a part of a test program on 24S-T aluminum alloy flat compression panels with longitudinal formed hat-section stiffeners. This part of the program is concerned with panels in which the thickness of the stiffener materials is 0.625 times the skin thickness. The results, presented in tabular and graphical form, show the effect of the relative dimensions of the panel on the buckling stress and the average stress at maximum load. Comparative envelope curves are presented for hat-stiffened and Z-stiffened panels having the same ratio of stiffener thickness to sheet thickness. These curves provide some indication of the relative structural efficiencies of the two types of panel.