The effects of graft geometry on the patency of a systemic-to-pulmonary shunt: a computational fluid dynamics study.

The modified Blalock-Taussig shunt is a palliative operation for some congenital heart diseases. An artificial conduit with antithrombotic surface placed between the subclavian (or innominate) and the pulmonary artery supplies blood to the lungs in defects with decreased pulmonary flow. Clotting of the graft is the main cause of its failure. Stenosis of the arteries is also observed. The objective of the present study was to investigate the flow pattern in the graft to investigate the possibility that clotting is initiated by the stimulation of platelets by high shear stress, and the possible effect of the pathological wall shear stress on the stenosis formation. The model included the left subclavian artery (LSA), the left pulmonary artery (LPA), and the graft. The three-dimensional relative position and size of the arteries was obtained from a CT scan of real anatomy. Four different types of the graft with two different diameters (3 and 4 mm) and two different shapes (straight and curved) of the pipe, and one variable diameter pipe were inserted in the model. A pulsatile flow of 0.81 L/min on average was assumed at the inlet to LSA, and 80% of the flow was directed through the graft. Computer simulations demonstrated a complex flow pattern with eddies and low velocity regions in the arteries at the anastomoses with the graft in all five models. An eddy was also found inside the straight 4 mm graft. A high pathological shear rate was present within the graft, with higher values in the 3 mm grafts. The fractional volume with a high (>2500 L/s) shear rate was between 2.5% and 4.5%, and that with a very high (>7500 L/s) shear rate between 0 and 1.5% of the model volume, and depended on the graft geometry and the phase of the cardiac cycle. Pathologically high (>3.5 Pa) and pathologically low (<1.0 Pa) wall shear stress, which may induce neointimal growth, was found in LSA and LPA. We conclude that the activation of platelets by high shear rate is possible within the graft, followed by their subsequent aggregation in the eddies with a low flow rate. Flow-induced changes of the vessel wall thickness (stenosis) can also appear, especially in the pulmonary artery.

[1]  A. Guyton,et al.  Human Physiology and Mechanisms of Disease , 1982 .

[2]  N. Hwang,et al.  Haemodynamics of angioaccess venous anastomoses. , 1991, Journal of biomedical engineering.

[3]  V. Didilis,et al.  Pulmonary artery stenosis after systemic-to-pulmonary shunt operations. , 1998, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[4]  F. Macartney,et al.  Modified Blalock-Taussig shunt. Use of subclavian artery orifice as flow regulator in prosthetic systemic-pulmonary artery shunts. , 1981, The Journal of thoracic and cardiovascular surgery.

[5]  Hans Scholz,et al.  Computational fluid dynamics and vascular access. , 2002, Artificial organs.

[6]  Edward G. Cape Editorial: Mathematical modeling in the evaluation and design of surgical procedure , 1996 .

[7]  J. Moake,et al.  Platelets and shear stress. , 1996, Blood.

[8]  R Pietrabissa,et al.  Use of computational fluid dynamics in the design of surgical procedures: application to the study of competitive flows in cavo-pulmonary connections. , 1996, The Journal of thoracic and cardiovascular surgery.

[9]  F. Migliavacca,et al.  Computational model of the fluid dynamics in systemic-to-pulmonary shunts. , 2000, Journal of biomechanics.

[10]  Alfio Quarteroni,et al.  Computational vascular fluid dynamics: problems, models and methods , 2000 .

[11]  S. Qureshi,et al.  Effects of modified and classic Blalock-Taussig shunts on the pulmonary arterial tree. , 1998, The Annals of thoracic surgery.

[12]  J. Verschakelen,et al.  Systemic to pulmonary artery shunting. , 1993, Journal belge de radiologie.

[13]  K. Gage,et al.  Modeling flow effects on thrombotic deposition in a membrane oxygenator. , 2000, Artificial organs.

[14]  C. Mavroudis,et al.  Pediatric Cardiac Surgery , 1994 .

[15]  M. R. Kaazempur-Mofrad,et al.  Computational Analysis of the Effects of Exercise on Hemodynamics in the Carotid Bifurcation , 2003, Annals of Biomedical Engineering.

[17]  Erwan Donal,et al.  Experimental study of laminar blood flow through an artery treated by a stent implantation: characterisation of intra-stent wall shear stress. , 2003, Journal of biomechanics.

[18]  Andreas O Frank,et al.  Computational fluid dynamics and stent design. , 2002, Artificial organs.

[19]  Pascal Verdonck The role of computational fluid dynamics for artificial organ design. , 2002, Artificial organs.

[20]  J. LaDisa,et al.  Three-Dimensional Computational Fluid Dynamics Modeling of Alterations in Coronary Wall Shear Stress Produced by Stent Implantation , 2003, Annals of Biomedical Engineering.

[21]  K. Affeld,et al.  Estimation of wall shear stress in bypass grafts with computational fluid dynamics method , 2001, The International journal of artificial organs.

[22]  E G Cape Mathematical modeling in the evaluation and design of surgical procedures. , 1996, The Journal of thoracic and cardiovascular surgery.

[23]  Thomas J. R. Hughes,et al.  Finite Element Modeling of Three-Dimensional Pulsatile Flow in the Abdominal Aorta: Relevance to Atherosclerosis , 2004, Annals of Biomedical Engineering.

[24]  M. Leval,et al.  Surgery for Congenital Heart Defects , 1994 .

[25]  G B Fiore,et al.  In vitro steady-flow analysis of systemic-to-pulmonary shunt haemodynamics. , 2001, Journal of biomechanics.