Development of anatomically and dielectrically accurate breast phantoms for microwave imaging applications

Breast cancer is one of the most common cancers in women. In the United States alone, it accounts for 31% of new cancer cases, and is second only to lung cancer as the leading cause of deaths in American women. More than 184,000 new cases of breast cancer are diagnosed each year resulting in approximately 41,000 deaths. Early detection and intervention is one of the most significant factors in improving the survival rates and quality of life experienced by breast cancer sufferers, since this is the time when treatment is most effective. One of the most promising breast imaging modalities is microwave imaging. The physical basis of active microwave imaging is the dielectric contrast between normal and malignant breast tissue that exists at microwave frequencies. The dielectric contrast is mainly due to the increased water content present in the cancerous tissue. Microwave imaging is non-ionizing, does not require breast compression, is less invasive than X-ray mammography, and is potentially low cost. While several prototype microwave breast imaging systems are currently in various stages of development, the design and fabrication of anatomically and dielectrically representative breast phantoms to evaluate these systems is often problematic. While some existing phantoms are composed of dielectrically representative materials, they rarely accurately represent the shape and size of a typical breast. Conversely, several phantoms have been developed to accurately model the shape of the human breast, but have inappropriate dielectric properties. This study will brie y review existing phantoms before describing the development of a more accurate and practical breast phantom for the evaluation of microwave breast imaging systems.

[1]  E.C. Fear,et al.  Tissue Sensing Adaptive Radar for Breast Cancer Detection—Experimental Investigation of Simple Tumor Models , 2005, IEEE Transactions on Microwave Theory and Techniques.

[2]  Paul M. Meaney,et al.  A clinical prototype for active microwave imaging of the breast , 2000 .

[3]  Elise Fear,et al.  Stable and Flexible Materials to Mimic the Dielectric Properties of Human Soft Tissues , 2014, IEEE Antennas and Wireless Propagation Letters.

[4]  A. Preece,et al.  Microwave Radar-Based Breast Cancer Detection: Imaging in Inhomogeneous Breast Phantoms , 2009, IEEE Antennas and Wireless Propagation Letters.

[5]  R. Bird,et al.  Analysis of cancers missed at screening mammography. , 1992, Radiology.

[6]  K. Low,et al.  Homogeneous and Heterogeneous Breast Phantoms for Ultra-Wideband Microwave Imaging Applications , 2010 .

[7]  Wee Chang Khor Microwave Imaging for Breast Cancer Detection , 2010 .

[8]  A. Taflove,et al.  Two-dimensional FDTD analysis of a pulsed microwave confocal system for breast cancer detection: fixed-focus and antenna-array sensors , 1998, IEEE Transactions on Biomedical Engineering.

[9]  J. Cullinan,et al.  Mammography and Beyond: Developing Technologies for the Early Detection of Breast Cancer , 2002 .

[10]  N. Behdad,et al.  MRI-Derived 3-D-Printed Breast Phantom for Microwave Breast Imaging Validation , 2012, IEEE Antennas and Wireless Propagation Letters.

[11]  Mark Coates,et al.  Time-domain microwave breast cancer detection: Experiments with comprehensive glandular phantoms , 2011, Asia-Pacific Microwave Conference 2011.

[12]  E. Porter,et al.  Time-domain microwave breast screening system: Testing with advanced realistic breast phantoms , 2012, 2012 6th European Conference on Antennas and Propagation (EUCAP).

[13]  E. Madsen,et al.  Tissue-mimicking phantom materials for narrowband and ultrawideband microwave applications , 2005, Physics in medicine and biology.

[14]  Barry D. Van Veen,et al.  Estimating the Breast Surface Using UWB Microwave Monostatic Backscatter Measurements , 2008, IEEE Transactions on Biomedical Engineering.

[15]  E. C. Fear,et al.  Average property estimation validation with realistic breast models , 2014, The 8th European Conference on Antennas and Propagation (EuCAP 2014).

[16]  Robert H. Svenson,et al.  Computational modeling of three-dimensional microwave tomography of breast cancer , 2001, IEEE Transactions on Biomedical Engineering.

[17]  Fuqiang Gao,et al.  Heterogeneous anthropomorphic phantoms with realistic dielectric properties for microwave breast imaging experiments , 2011, Microwave and optical technology letters.

[18]  M. Lindstrom,et al.  A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries , 2007, Physics in medicine and biology.

[19]  A. Taflove,et al.  Three-dimensional FDTD analysis of a pulsed microwave confocal system for breast cancer detection: design of an antenna-array element , 1999 .

[20]  E. Fear,et al.  Phantoms for testing radar-based microwave breast imaging , 2009, 2009 13th International Symposium on Antenna Technology and Applied Electromagnetics and the Canadian Radio Science Meeting.