AlGaN/GaN High Electron Mobility Transistor-Based Biosensor for the Detection of C-Reactive Protein

In this paper, we propose an AlGaN/GaN high electron mobility transistor (HEMT)-based biosensor for the detection of C-reactive protein (CRP) using a null-balancing circuit. A null-balancing circuit was used to measure the output voltage of the sensor directly. The output voltage of the proposed biosensor was varied by antigen-antibody interactions on the gate surface due to CRP charges. The AlGaN/GaN HFET-based biosensor with null-balancing circuit applied shows that CRP can be detected in a wide range of concentrations, varying from 10 ng/mL to 1000 ng/mL. X-ray photoelectron spectroscopy was carried out to verify the immobilization of self-assembled monolayer with Au on the gated region.

[1]  M. Pfeffer,et al.  A sensitive cardiac troponin T assay in stable coronary artery disease. , 2009, The New England journal of medicine.

[2]  Kuo-Chien Tsao,et al.  Development of ELISA on microplate for serum C-reactive protein and establishment of age-dependent normal reference range. , 2002, Clinica chimica acta; international journal of clinical chemistry.

[3]  Jang-Kyoo Shin,et al.  Differential-Mode Biosensor Using Dual Extended-Gate Metal-Oxide-Semiconductor Field-Effect Transistors , 2012 .

[4]  T. P. Chow,et al.  Wide bandgap compound semiconductors for superior high-voltage unipolar power devices , 1994 .

[5]  M. Tarlov,et al.  Quantitative analysis and characterization of DNA immobilized on gold. , 2003, Journal of the American Chemical Society.

[6]  J. J. Chen,et al.  Electrical detection of deoxyribonucleic acid hybridization with AlGaN/GaN high electron mobility transistors , 2006 .

[7]  W. Lu,et al.  AlGaN/GaN FET for DNA hybridization detection , 2011 .

[8]  Francisco E. G. Guimarães,et al.  Self-Assembled Films of Dendrimers and Metallophthalocyanines as FET-Based Glucose Biosensors , 2011, Sensors.

[9]  A new pH-ISFET based dissolved oxygen sensor by employing electrolysis of oxygen , 1996 .

[10]  Amir Dabiran,et al.  Electrical detection of immobilized proteins with ungated AlGaN∕GaN high-electron-mobility Transistors , 2005 .

[11]  J. Tomasi,et al.  Use of whole Streptococcus pneumoniae cells as a solid phase sorbent for C-reactive protein measurement by ELISA. , 1985, JIM - Journal of Immunological Methods.

[12]  F. V. Santos,et al.  New ISFET sensor interface circuit for biomedical applications , 1999 .

[13]  S. Wood,et al.  The physiological structure of human C-reactive protein and its complex with phosphocholine. , 1999, Structure.

[14]  A. Gautier,et al.  C-reactive protein , 2005 .

[15]  M. Bissell A Sensitive Cardiac Troponin T Assay in Stable Coronary Artery Disease , 2011 .

[16]  Chia-Hua Ho,et al.  A CMOS-Compatible Poly-Si Nanowire Device with Hybrid Sensor/Memory Characteristics for System-on-Chip Applications , 2012, Sensors.

[17]  Wolfgang J. Parak,et al.  Time-Resolved Fluorescence Immunoassay for C-Reactive Protein Using Colloidal Semiconducting Nanoparticles , 2011, Sensors.

[18]  Yang‐Kyu Choi,et al.  CRP detection from serum for chip-based point-of-care testing system. , 2013, Biosensors & bioelectronics.

[19]  S. Islam,et al.  Direct Label-Free Electrical Immunodetection of Transplant Rejection Protein Biomarker in Physiological Buffer Using Floating Gate AlGaN/GaN High Electron Mobility Transistors , 2014, IEEE Transactions on NanoBioscience.

[20]  M. Higashiwaki,et al.  AlGaN/GaN MIS-HFETs with f/sub T/ of 163 GHz using cat-CVD SiN gate-insulating and passivation Layers , 2006, IEEE Electron Device Letters.

[21]  Heng Yuan,et al.  MOSFET-BJT hybrid mode of the gated lateral bipolar junction transistor for C-reactive protein detection. , 2011, Biosensors & bioelectronics.

[22]  Geunbae Lim,et al.  An extended gate FET-based biosensor integrated with a Si microfluidic channel for detection of protein complexes , 2006 .