4D respiratory motion-corrected Rb-82 myocardial perfusion PET image reconstruction

Routine clinical myocardial perfusion (MP) PET imaging involves the use of cardiac gating only. Nonetheless, respiratory motion of the heart can considerably degrade the quality of MP images and the quantitative accuracy of myocardial uptake estimates. We first performed a quantitative evaluation of the degrading contributions of cardiac (C) and respiratory (R) motion, as well as non-motion factors of Rb-82 positron range, photon non-collinearity, crystal scattering and penetration. For a normal human simulated phantom, we showed that the combination of all above factors resulted in −48% underestimation of myocardial activity, while corrections for all non-motion factors resulted in 21%, 36% and 41% underestimated myocardial activities in the presence of C, R and C&R motion. This means that compensation for respiratory motion must be considered as critical towards achieving overall motion compensation and/or resolution modeling. To achieve respiratory motion compensation, we used translation motion vectors to first match respiratory-only gated images to the end-expiration reference frame. Next, for each cardiac gate, a 4D EM reconstruction algorithm was applied to the R-gated data within that cardiac phase. Three techniques were compared involving reconstructions of (a) a single R-gate only, and all R-gates (b) without and (c) with respiratory motion correction (MC). Using simulated PET data, quantitative comparisons of noise vs. bias trace-off curves indicated notable improvements for the proposed 4D respiratory MC method. Using CHO analysis as applied to the task of perfusion defect detection, ROC analysis of the three methods resulted in AUC values of 0.610±0.039, 0.645±0.038 and 0.821±0.029. The CLABROC statistical test revealed that the proposed MC technique significantly outperformed the other two methods in the task of defect detection.

[1]  D E Kuhl,et al.  Comparison of rubidium-82 positron emission tomography and thallium-201 SPECT imaging for detection of coronary artery disease. , 1991, The American journal of cardiology.

[2]  T. Ruddy,et al.  Single-Phase CT Aligned to Gated PET for Respiratory Motion Correction in Cardiac PET/CT , 2010, The Journal of Nuclear Medicine.

[3]  M. Lauer,et al.  Incremental value of rubidium-82 positron emission tomography for prognostic assessment of known or suspected coronary artery disease. , 1997, The American journal of cardiology.

[4]  D. Shanno Conditioning of Quasi-Newton Methods for Function Minimization , 1970 .

[5]  Josef Machac,et al.  Cardiac positron emission tomography imaging. , 2005, Seminars in nuclear medicine.

[6]  D. Lalush,et al.  Comparison of Hotelling observer models and human observers in defect detection from myocardial SPECT imaging , 1999 .

[7]  W. J. Maclntyre,et al.  Measurement of cardiac output with first-pass determination during rubidium-82 PET myocardial perfusion imaging , 1996, European Journal of Nuclear Medicine.

[8]  R. deKemp,et al.  Detection of serial changes in absolute myocardial perfusion with 82Rb PET. , 2000, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  Val J Lowe,et al.  NEMA NU 2-2001 performance measurements of an LYSO-based PET/CT system in 2D and 3D acquisition modes. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  Lei Xing,et al.  Model-based image reconstruction for four-dimensional PET. , 2006, Medical physics.

[11]  S. Bergmann,et al.  Assessment of myocardial viability. , 2005, Seminars in nuclear medicine.

[12]  A. Rahmim,et al.  System Matrix Modeling of Externally Tracked Motion , 2006, 2006 IEEE Nuclear Science Symposium Conference Record.

[13]  Arman Rahmim,et al.  Analytic system matrix resolution modeling in PET: An application to Rb-82 cardiac imaging , 2008, ISBI.

[14]  O Muzik,et al.  Early Detection of Abnormal Coronary Flow Reserve in Asymptomatic Men at High Risk for Coronary Artery Disease Using Positron Emission Tomography , 1994, Circulation.

[15]  John D Friedman,et al.  Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT , 2006, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[16]  Raymond C. Boston,et al.  Dynamic Imaging of Allogeneic Mesenchymal Stem Cells Trafficking to Myocardial Infarction , 2005, Circulation.

[17]  Nassir Navab,et al.  Dual cardiac–respiratory gated PET: implementation and results from a feasibility study , 2007, European Journal of Nuclear Medicine and Molecular Imaging.

[18]  L. Shaw,et al.  Prognostic value of gated myocardial perfusion SPECT , 2004, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[19]  Wolfgang Enghardt,et al.  Attenuation correction of four dimensional (4D) PET using phase-correlated 4D-computed tomography. , 2008, Physics in medicine and biology.

[20]  Habib Zaidi,et al.  Four-dimensional (4D) image reconstruction strategies in dynamic PET: beyond conventional independent frame reconstruction. , 2009, Medical physics.

[21]  K. Lance Gould,et al.  Clinical cardiac PET using generator-produced Rb-82: A review , 1989, CardioVascular and Interventional Radiology.

[22]  Dean F. Wong,et al.  Accurate Event-Driven Motion Compensation in High-Resolution PET Incorporating Scattered and Random Events , 2008, IEEE Transactions on Medical Imaging.

[23]  Frank J. Rybicki,et al.  Interrelation of Coronary Calcification, Myocardial Ischemia, and Outcomes in Patients With Intermediate Likelihood of Coronary Artery Disease: A Combined Positron Emission Tomography/Computed Tomography Study , 2008, Circulation.

[24]  John W. Clark,et al.  A motion-incorporated reconstruction method for gated PET studies , 2006, Physics in medicine and biology.

[25]  N. Mullani,et al.  Noninvasive assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilation. VIII. Clinical feasibility of positron cardiac imaging without a cyclotron using generator-produced rubidium-82. , 1986, Journal of the American College of Cardiology.

[26]  P. Herrero,et al.  Implementation and evaluation of a two-compartment model for quantification of myocardial perfusion with rubidium-82 and positron emission tomography. , 1992, Circulation research.

[27]  J. Machac,et al.  Comparison of 2-dimensional and 3-dimensional 82Rb myocardial perfusion PET imaging. , 2003, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[28]  G Germano,et al.  The role of nuclear cardiology in clinical decision making. , 1999, Seminars in nuclear medicine.

[29]  G. Hutchins,et al.  Myocardial rubidium-82 tissue kinetics assessed by dynamic positron emission tomography as a marker of myocardial cell membrane integrity and viability. , 1996, Circulation.

[30]  Florian Büther,et al.  Organ movement reduction in PET/CT using dual-gated list-mode acquisition. , 2006, Zeitschrift fur medizinische Physik.

[31]  D. Visvikis,et al.  Respiratory synchronized CT image generation from 4D PET acquisitions , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[32]  Habib Zaidi,et al.  Strategies for Motion Tracking and Correction in PET. , 2007, PET clinics.

[33]  Keiichiro Yoshinaga,et al.  What is the prognostic value of myocardial perfusion imaging using rubidium-82 positron emission tomography? , 2006, Journal of the American College of Cardiology.

[34]  Arman Rahmim,et al.  Optimization of Rb-82 PET acquisition and reconstruction protocols for myocardial perfusion defect detection , 2008, 2008 IEEE Nuclear Science Symposium Conference Record.

[35]  A J Reader,et al.  List-mode-based reconstruction for respiratory motion correction in PET using non-rigid body transformations , 2007, Physics in medicine and biology.

[36]  Raymond Kwong,et al.  Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease. , 2007, Journal of the American College of Cardiology.

[37]  G Bosmans,et al.  Phased attenuation correction in respiration correlated computed tomography/positron emitted tomography. , 2006, Medical physics.