Accuracy, reproducibility, and dimensional stability of additively manufactured surgical templates.

STATEMENT OF PROBLEM Additively manufactured surgical templates are commonly used for computer-guided implant placement. However, their accuracy, reproducibility, and dimensional stability have not been thoroughly investigated with the different 3D printers and materials used for their fabrication. PURPOSE The purpose of this in vitro study was to evaluate the accuracy, reproducibility, and dimensional stability of additively manufactured surgical templates fabricated by using different 3D printers. MATERIAL AND METHODS Thirty surgical templates were designed and additively manufactured from 3 different 3D printers as follows: group SLA (n=10) was fabricated by using a desktop stereolithography (SLA) 3D printer and photopolymerizing resin; group PolyJet (n=10) was fabricated by using a PolyJet 3D printer and photopolymerizing resins; and group DMP (n=10) was fabricated by using a direct metal printing (DMP) system and Co-Cr metal alloy. All surgical templates were scanned by using a laser scanner within 36 hours of production and digitalized again 1 month later. All scanned files were compared with the corresponding designed files in a surface matching software program. The mean deviation root mean square (RMS, measured in mm, representing accuracy), percentage of measurement data points within 1 standard deviation of mean RMS (in %, representing reproducibility), and dimensional changes were determined and compared. RESULTS At the postproduction stage, group PolyJet was most accurate with the lowest RMS value of 0.10 ±0.02 mm and highest reproducibility with 93.07 ±1.54% of measurement data points within 1 standard deviation of mean RMS. After 1-month storage, group PolyJet(1month) remained the most accurate with the lowest RMS value of 0.14 ±0.03 mm and the highest reproducibility value of 92.46 ±1.50%. For dimensional stability, group SLA versus group SLA(1month) comparison showed a significant decrease in accuracy (RMS values of 0.20 ±0.08 mm versus 0.25 ±0.08 mm, P<.001) and reproducibility (88.16 ±3.66% versus 86.10 ±4.16%, P=.012). Group PolyJet versus group PolyJet(1month) comparison only showed significant changes in accuracy (RMS values of 0.10 ±0.02 mm versus 0.14 ±0.03 mm, P=.011). Group DMP versus group DMP(1month) comparison showed no significant changes in accuracy (RMS values of 0.19 ±0.03 mm versus 0.20 ±0.04 mm, P=.981) or reproducibility (89.77 ±1.61% versus 89.74 ±2.24%, P=1.000). CONCLUSIONS Printed resin surgical templates produced by using the PolyJet 3D printer showed higher accuracy and reproducibility than those produced by using the desktop SLA 3D printer and printed Co-Cr surgical templates at both the postproduction stage and after 1-month storage. The level of accuracy and reproducibility in printed Co-Cr surgical templates was not affected by 1-month storage.

[1]  Ersilia Barbato,et al.  The Influence of the Tolerance between Mechanical Components on the Accuracy of Implants Inserted with a Stereolithographic Surgical Guide: A Retrospective Clinical Study. , 2015, Clinical implant dentistry and related research.

[2]  A. Greenberg Digital technologies for dental implant treatment planning and guided surgery. , 2015, Oral and maxillofacial surgery clinics of North America.

[3]  Reinhilde Jacobs,et al.  A randomized clinical trial comparing guided implant surgery (bone- or mucosa-supported) with mental navigation or the use of a pilot-drill template. , 2014, Journal of clinical periodontology.

[4]  Jai-Young Koak,et al.  Comparison of five-axis milling and rapid prototyping for implant surgical templates. , 2014, The International journal of oral & maxillofacial implants.

[5]  Wei-Shao Lin,et al.  Digital approach to planning computer-guided surgery and immediate provisionalization in a partially edentulous patient. , 2016, The Journal of prosthetic dentistry.

[6]  Isabelle Borget,et al.  Advantages and disadvantages of 3-dimensional printing in surgery: A systematic review. , 2016, Surgery.

[7]  Mathew T Kattadiyil,et al.  Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques. , 2016, The Journal of prosthetic dentistry.

[8]  Jeffrey W Stansbury,et al.  3D printing with polymers: Challenges among expanding options and opportunities. , 2016, Dental materials : official publication of the Academy of Dental Materials.

[9]  W. Brantley,et al.  Internal fit evaluation of crowns prepared using a new dental crown fabrication technique: laser-sintered Co-Cr crowns. , 2009, The Journal of prosthetic dentistry.

[10]  G. Schiroli,et al.  Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. , 2009, The International journal of oral & maxillofacial implants.

[11]  Pier Paolo Poli,et al.  Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study , 2014, Journal of periodontal & implant science.

[12]  Per Vult von Steyern,et al.  The fit of cobalt-chromium three-unit fixed dental prostheses fabricated with four different techniques: a comparative in vitro study. , 2011, Dental materials : official publication of the Academy of Dental Materials.

[13]  Ammar A. Alsheghri,et al.  Removable partial denture alloys processed by laser-sintering technique. , 2018, Journal of biomedical materials research. Part B, Applied biomaterials.

[14]  Marc Quirynen,et al.  Tolerance within the sleeve inserts of different surgical guides for guided implant surgery. , 2013, Clinical oral implants research.

[15]  N. Van Assche,et al.  Accuracy assessment of computer-assisted flapless implant placement in partial edentulism. , 2010, Journal of clinical periodontology.

[16]  P. Shen,et al.  Accuracy evaluation of computer-designed surgical guide template in oral implantology. , 2015, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[17]  Abdullah Barazanchi Bds,et al.  Additive Technology: Update on Current Materials and Applications in Dentistry , 2016 .

[18]  E. Machtei,et al.  Accuracy of a computerized tomography-guided template-assisted implant placement system: an in vitro study. , 2009, Clinical oral implants research.

[19]  Daniel R Llop,et al.  Creation of a 3-dimensional virtual dental patient for computer-guided surgery and CAD-CAM interim complete removable and fixed dental prostheses: A clinical report. , 2017, The Journal of prosthetic dentistry.

[20]  Gerlig Widmann,et al.  Accuracy of Image-Fusion Stereolithographic Guides: Mapping CT Data with Three-Dimensional Optical Surface Scanning. , 2015, Clinical implant dentistry and related research.

[21]  R Jacobs,et al.  Accuracy of computer-aided implant placement. , 2012, Clinical oral implants research.

[22]  Seok-Hwan Cho,et al.  Comparison of accuracy and reproducibility of casts made by digital and conventional methods. , 2015, The Journal of prosthetic dentistry.

[23]  G. Widmann,et al.  Cone Beam Computed Tomography vs Multislice Computed Tomography in Computer-Aided Design/Computer-Assisted Manufacture Guided Implant Surgery Based on Three-Dimensional Optical Scanning and Stereolithographic Guides: Does Image Modality Matter? , 2016, The International journal of oral & maxillofacial implants.

[24]  Li Chen,et al.  Accuracy and reproducibility of virtual edentulous casts created by laboratory impression scan protocols , 2018, The Journal of prosthetic dentistry.

[25]  Tiny Boumans,et al.  A clinically relevant accuracy study of computer-planned implant placement in the edentulous maxilla using mucosa-supported surgical templates. , 2015, Clinical implant dentistry and related research.

[26]  Gerlig Widmann,et al.  Accuracy in computer-aided implant surgery--a review. , 2006, The International journal of oral & maxillofacial implants.

[27]  P Ausiello,et al.  Accuracy evaluation of surgical guides in implant dentistry by non-contact reverse engineering techniques. , 2012, Dental materials : official publication of the Academy of Dental Materials.

[28]  Urs C Belser,et al.  Stability of contour augmentation and esthetic outcomes of implant-supported single crowns in the esthetic zone: 3-year results of a prospective study with early implant placement postextraction. , 2011, Journal of periodontology.

[29]  Robert W Emery,et al.  Implant Placement Accuracy Using Dynamic Navigation. , 2017, The International journal of oral & maxillofacial implants.