Hematological advantage of a membrane oxygenator over a bubble oxygenator in long perfusions.
暂无分享,去创建一个
J. Soons | C. Wildevuur | J. Leusink | P. Boonstra | F. Vermeulen | A. van Zalk | E. D. de Nooy | F.E.E. Vermeulen | E. H. D. Nooy | A. V. Zalk | J.B.J. Soons | C. Wildevuur
[1] C. Wildevuur,et al. Clinical study of blood trauma during perfusion with membrane and bubble oxygenators. , 1982, The Journal of thoracic and cardiovascular surgery.
[2] C. Wildevuur. Towards safer cardiopulmonary bypass , 1981 .
[3] G. Wright. Haematological effects of cardiotomy suction , 1981 .
[4] E. Hessel,et al. Mechanism of abnormal bleeding in patients undergoing cardiopulmonary bypass: acquired transient platelet dysfunction associated with selective alpha-granule release. , 1980, Blood.
[5] D. W. Miller,et al. Membrane versus bubble oxygenator for cardiac operations. A prospective randomized study. , 1980, The Journal of thoracic and cardiovascular surgery.
[6] E. Peirce. The membrane versus bubble oxygenator controversy. , 1980, The Annals of thoracic surgery.
[7] R. Sade,et al. A prospective randomized study of membrane versus bubble oxygenators in children. , 1980, The Annals of thoracic surgery.
[8] H. T. ten Duis,et al. Hematologic aspects of cardiotomy suction in cardiac operations. , 1980, The Journal of thoracic and cardiovascular surgery.
[9] R. Dewall,et al. Membrane vs bubble oxygenators: a prospective study of 52 patients. , 1979, Archives of surgery.
[10] J. D. Brooks,et al. Comparison of bubble and membrane oxygenators in short and long perfusions. , 1979, The Journal of thoracic and cardiovascular surgery.
[11] W. Seybold-epting,et al. Clinical comparison between membrane and bubble oxygenators in cardiopulmonary bypass. , 1979, The Journal of cardiovascular surgery.
[12] L. Edmunds,et al. Relationship between platelet count and cardiotomy suction return. , 1978, The Annals of thoracic surgery.
[13] P. Kalmar,et al. Intraoperative myocardial protection by cardioplegia in hypothermia. , 1978, The Journal of thoracic and cardiovascular surgery.
[14] H. T. ten Duis,et al. Improved hemocompatibility in open heart surgery. , 1978, Transactions - American Society for Artificial Internal Organs.
[15] J D Hellums,et al. Morphological, biochemical, and functional changes in human platelets subjected to shear stress. , 1975, The Journal of laboratory and clinical medicine.
[16] M. Debakey,et al. Membrane vs Bubble Oxygenator: Clinical Comparsion , 1975, Annals of surgery.
[17] S P Sutera,et al. Shear-induced changes in permeability of human RBC to sodium. , 1974, Transactions - American Society for Artificial Internal Organs.
[18] G. Celesia,et al. Clinical comparison of the General Electric-Peirce membrane lung and bubble oxygenator for prolonged cardiopulmonary bypass. , 1973, Surgery.
[19] L. Harker,et al. The bleeding time as a screening test for evaluation of platelet function. , 1972, The New England journal of medicine.
[20] J D Hellums,et al. Red blood cell damage by shear stress. , 1972, Biophysical journal.
[21] W. Coakley,et al. Shear fragility of human erythrocytes. , 1971, Biorheology.
[22] D. Drabkin,et al. SPECTROPHOTOMETRIC STUDIES: SPECTROPHOTOMETRIC CONSTANT FOR COMMON HAEMOGLOBIN DERIVATIVES IN HUMAN, DOG AND RABBIT BLOOD , 1932 .