Review of numerical simulation of capillary tube using refrigerant mixtures

A detailed one-dimensional steady and transient state numerical simulation of the thermal and fluid-dynamic behaviour of capillary tube expansion devices considering metastable region and working with pure and mixed refrigerants has been developed and presented in previous works [Appl. Therm. Eng. 22 (2002) 173; Appl. Therm. Eng. 22 (2002) 379]. The discretized governing equations are coupled using an implicit step-by-step method. Due to the changes observed in the thermo-physical properties of mixtures using REFPROP v7.0 [Reference Fluid Thermodynamic and Transport Properties, NIST Standard Reference Database 23, Gaithersbug, MD 20899, USA, 2002] compared to REFPROP v5.0 [NIST Thermodynamic Properties of Refrigerants and Refrigerant Mixtures Database, Standard Reference Data Program, Gaithersbug, MD 20899, USA (February 1996)]; an extensive comparison of the numerical simulation developed with experimental data presented in the technical literature will be shown in order to demonstrate the accuracy of this detailed model. Finally, refrigerant-specific rating charts to predict in an easy way R-407C flow rates through adiabatic capillary tube are shown and used.

[1]  Samuel M. Sami,et al.  Prediction of capillary tubes with alternative refrigerants to CFC‐502 , 2001 .

[2]  Samuel M. Sami,et al.  Modelling of capillary tubes behaviour with HCFC 22 ternary alternative refrigerants , 1998 .

[3]  M. McLinden,et al.  NIST Standard Reference Database 23 - NIST Thermodynamic and Transport Properties REFPROP, Version 7.0 , 2002 .

[4]  V. Gnielinski New equations for heat and mass transfer in turbulent pipe and channel flow , 1976 .

[5]  S. T. Ro,et al.  Experimental and Numerical Studies on Adiabatic Flow of HFC Mixtures in Capillary Tubes , 1996 .

[6]  C. Pérez-Segarra,et al.  Numerical simulation of capillary tube expansion devices behaviour with pure and mixed refrigerants considering metastable region. Part I: mathematical formulation and numerical model , 2002 .

[7]  L. Friedel Improved Friction Pressure Drop Correlation for Horizontal and Vertical Two-Phase Pipe Flow , 1979 .

[8]  C. Pérez-Segarra,et al.  Numerical simulation of capillary-tube expansion devices , 1995 .

[9]  S. Lin,et al.  Local frictional pressure drop during vaporization of R-12 through capillary tubes , 1991 .

[10]  S. L. Braga,et al.  Critical flow of refrigerants through adiabatic capillary tubes: Experimental study of zeotropic mixtures R-407a and R-404a , 2000 .

[11]  Samuel M. Sami,et al.  Numerical prediction of capillary tube behaviour with pure and binary alternative refrigerants , 1998 .

[12]  G. Hewitt,et al.  Annular two-phase flow , 1970 .

[13]  Carlos D. Perez-Segarra,et al.  Numerical simulation of capillary-tube expansion devices behaviour with pure and mixed refrigerants considering metastable region. Part II: experimental validation and parametric studies , 2002 .

[14]  Jean-Marie Seynhaeve,et al.  A Model for Choked Flow-through Cracks With Inlet Subcooling , 1993 .

[15]  C. K. Rice The effect of void fraction correlation and heat flux assumption on refrigerant charge inventory predictions , 1987 .

[16]  Flávio Augusto Sanzovo Fiorelli,et al.  Refrigerant Mixtures Flow Through Capillary Tubes: A Comparison Between Homogeneous and Separated-Flow Models , 2003 .