Precise landmarking in computer assisted total knee arthroplasty is critical to final alignment

Image‐free computer navigation systems build a frame of reference of a patient's knee from anatomical landmarks entered by the surgeon during the initial stage of total knee arthroplasty. We performed tibial cuts on 70 sawbones using computer navigation. All landmarks were marked identically except for the tibial mechanical entry point, which was marked correctly in 10 bones and with offsets of 5, 10, and 15 mm medially and laterally in the others. The actual coronal angle of the tibial cuts was measured directly and compared to the final angle given by the navigation system. Significant deviations of the coronal angle were observed in the trial groups. Landmarking errors during navigated TKA can lead to inaccurate tibial bone cuts. This navigation system did not have an iterative software method to verify landmarking errors that can lead to inaccurate tibia bone cuts. Published by Wiley Periodicals, Inc. J Orthop Res 28:1355–1359, 2010

[1]  Peter Loan,et al.  Computer-Assisted Navigation in Total Knee Replacement: Results of an Initial Experience in Thirty-five Patients , 2002, The Journal of bone and joint surgery. American volume.

[2]  Wojciech Widuchowski,et al.  [Total knee arthroplasty]. , 2004, Wiadomosci lekarskie.

[3]  L. Whiteside,et al.  The Anteroposterior Axis for Femoral Rotational Alignment in Valgus Total Knee Arthroplasty , 1995, Clinical orthopaedics and related research.

[4]  S. Delp,et al.  Computer assisted knee replacement. , 1998, Clinical orthopaedics and related research.

[5]  Christian Hoser,et al.  Improved accuracy of component alignment with the implementation of image-free navigation in total knee arthroplasty , 2008, Knee Surgery, Sports Traumatology, Arthroscopy.

[6]  M. Ritter,et al.  Postoperative alignment of total knee replacement. Its effect on survival. , 1994, Clinical orthopaedics and related research.

[7]  Scott L Delp,et al.  The variability of femoral rotational alignment in total knee arthroplasty. , 2005, The Journal of bone and joint surgery. American volume.

[8]  P. Lotke,et al.  Long-term results after total condylar knee arthroplasty. Significance of radiolucent lines. , 1987, Clinical orthopaedics and related research.

[9]  Arno Martin,et al.  Imageless Navigation for TKA Increases Implantation Accuracy , 2007, Clinical orthopaedics and related research.

[10]  Markus Tingart,et al.  Intraoperative cutting errors in total knee arthroplasty , 2005, Archives of Orthopaedic and Trauma Surgery.

[11]  L. Dorr,et al.  Technical considerations in total knee arthroplasty. , 1986, Clinical orthopaedics and related research.

[12]  T P Ng,et al.  Intraobserver errors in obtaining visually selected anatomic landmarks during registration process in nonimage-based navigation-assisted total knee arthroplasty: a cadaveric experiment. , 2005, The Journal of arthroplasty.

[13]  D. Banzer,et al.  Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. , 2003, The Journal of bone and joint surgery. British volume.

[14]  Richard L Wixson,et al.  Computer assisted navigation in total knee arthroplasty: improved coronal alignment. , 2005, The Journal of arthroplasty.

[15]  S David Stulberg,et al.  How accurate is current TKR instrumentation? , 2003, Clinical orthopaedics and related research.

[16]  Alberto Leardini,et al.  Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty. , 2008, The Journal of bone and joint surgery. American volume.

[17]  Markus Tingart,et al.  Computer-assisted total knee arthroplasty versus the conventional technique: how precise is navigation in clinical routine? , 2007, Knee Surgery, Sports Traumatology, Arthroscopy.

[18]  C. Plaskos,et al.  Bone cutting errors in total knee arthroplasty. , 2002, The Journal of arthroplasty.

[19]  Leo Joskowicz,et al.  NAVIGATED TOTAL KNEE REPLACEMENT – A COMPREHENSIVE CLINICAL STATE OF THE ART STUDY , 2008 .

[20]  R P Pitto,et al.  Accuracy of a computer-assisted navigation system for total knee replacement. , 2006, The Journal of bone and joint surgery. British volume.

[21]  Marc Mombert,et al.  Navigated total knee arthroplasty: a radiological analysis of 42 randomised cases. , 2007, Acta orthopaedica Belgica.