3₁₀-helix conformation facilitates the transition of a voltage sensor S4 segment toward the down state.

The activation of voltage-gated ion channels is controlled by the S4 helix, with arginines every third residue. The x-ray structures are believed to reflect an open-inactivated state, and models propose combinations of translation, rotation, and tilt to reach the resting state. Recently, experiments and simulations have independently observed occurrence of 3(10)-helix in S4. This suggests S4 might make a transition from α- to 3(10)-helix in the gating process. Here, we show 3(10)-helix structure between Q1 and R3 in the S4 segment of a voltage sensor appears to facilitate the early stage of the motion toward a down state. We use multiple microsecond-steered molecular simulations to calculate the work required for translating S4 both as α-helix and transformed to 3(10)-helix. The barrier appears to be caused by salt-bridge reformation simultaneous to R4 passing the F233 hydrophobic lock, and it is almost a factor-two lower with 3(10)-helix. The latter facilitates translation because R2/R3 line up to face E183/E226, which reduces the requirement to rotate S4. This is also reflected in a lower root mean-square deviation distortion of the rest of the voltage sensor. This supports the 3(10) hypothesis, and could explain some of the differences between the open-inactivated- versus activated-states.

[1]  K. Swartz,et al.  Sensing voltage across lipid membranes , 2008, Nature.

[2]  M. Parrinello,et al.  Accurate sampling using Langevin dynamics. , 2007, Physical review. E, Statistical, nonlinear, and soft matter physics.

[3]  Y. Okamura Biodiversity of voltage sensor domain proteins , 2007, Pflügers Archiv - European Journal of Physiology.

[4]  Andrei L. Lomize,et al.  OPM: Orientations of Proteins in Membranes database , 2006, Bioinform..

[5]  O. Berger,et al.  Molecular dynamics simulations of a fluid bilayer of dipalmitoylphosphatidylcholine at full hydration, constant pressure, and constant temperature. , 1997, Biophysical journal.

[6]  K Schulten,et al.  VMD: visual molecular dynamics. , 1996, Journal of molecular graphics.

[7]  Erik Lindahl,et al.  Conformational Changes and Slow Dynamics through Microsecond Polarized Atomistic Molecular Simulation of an Integral Kv1.2 Ion Channel , 2009, PLoS Comput. Biol..

[8]  M. Sansom,et al.  How Does a Voltage Sensor Interact with a Lipid Bilayer? Simulations of a Potassium Channel Domain , 2007, Structure.

[9]  Youxing Jiang,et al.  The principle of gating charge movement in a voltage-dependent K+ channel , 2003, Nature.

[10]  Xiao Tao,et al.  A Gating Charge Transfer Center in Voltage Sensors , 2010, Science.

[11]  E. Isacoff,et al.  Spectroscopic mapping of voltage sensor movement in the Shaker potassium channel , 1999, Nature.

[12]  R. Horn,et al.  Stirring up controversy with a voltage sensor paddle , 2004, Trends in Neurosciences.

[13]  Francisco Bezanilla,et al.  Voltage Sensor Movements , 2002, The Journal of general physiology.

[14]  Francisco Bezanilla,et al.  Atomic scale movement of the voltage-sensing region in a potassium channel measured via spectroscopy , 1999, Nature.

[15]  W. L. Jorgensen,et al.  Comparison of simple potential functions for simulating liquid water , 1983 .

[16]  H. Guy,et al.  Molecular model of the action potential sodium channel. , 1986, Proceedings of the National Academy of Sciences of the United States of America.

[17]  Yu Huang,et al.  Electrostatic interactions of S4 voltage sensor in shaker K+ channel , 1995, Neuron.

[18]  Klaus Schulten,et al.  Biophysical Journal, Volume 98 Supporting Material Calculation of the Gating Charge for the Kv1.2 Voltage–activated Potassium Channel , 2022 .

[19]  Francisco Bezanilla,et al.  Voltage-Sensing Residues in the S2 and S4 Segments of the Shaker K+ Channel , 1996, Neuron.

[20]  David Baker,et al.  Voltage sensor conformations in the open and closed states in ROSETTA structural models of K(+) channels. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[21]  W. Catterall,et al.  Molecular properties of voltage-sensitive sodium channels. , 1986, Annual review of biochemistry.

[22]  D. Tobias,et al.  Down-state model of the voltage-sensing domain of a potassium channel. , 2010, Biophysical journal.

[23]  M. E. Karpen,et al.  Differences in the amino acid distributions of 310‐helices and α‐helices , 1992 .

[24]  R. Horn Explorations of voltage-dependent conformational changes using cysteine scanning. , 1998, Methods in enzymology.

[25]  Yuichi Kanaoka,et al.  Primary structure of Electrophorus electricus sodium channel deduced from cDNA sequence , 1984, Nature.

[26]  Ehud Y Isacoff,et al.  Subunit organization and functional transitions in Ci-VSP , 2008, Nature Structural &Molecular Biology.

[27]  William A. Catterall,et al.  Voltage-dependent gating of sodium channels: correlating structure and function , 1986, Trends in Neurosciences.

[28]  Yasushi Okamura,et al.  A Voltage Sensor-Domain Protein Is a Voltage-Gated Proton Channel , 2006, Science.

[29]  Roderick MacKinnon,et al.  Contribution of the S4 Segment to Gating Charge in the Shaker K+ Channel , 1996, Neuron.

[30]  P. Kollman,et al.  Settle: An analytical version of the SHAKE and RATTLE algorithm for rigid water models , 1992 .

[31]  J. Morais-Cabral,et al.  Structure of the transmembrane regions of a bacterial cyclic nucleotide-regulated channel , 2008, Proceedings of the National Academy of Sciences.

[32]  E. Campbell,et al.  Atomic structure of a voltage-dependent K+ channel in a lipid membrane-like environment , 2007, Nature.

[33]  R. Horn,et al.  Evidence for voltage-dependent S4 movement in sodium channels , 1995, Neuron.

[34]  C. Brooks,et al.  Thermodynamics and mechanism of alpha helix initiation in alanine and valine peptides. , 1991, Biochemistry.

[35]  G. Marshall,et al.  THE MOLTEN HELIX : EFFECTS OF SOLVATION ON THE ALPHA - TO 310-HELICAL TRANSITION , 1995 .

[36]  L. Pal,et al.  Novel protein structural motifs containing two-turn and longer 3(10)-helices. , 1999, Protein engineering.

[37]  D. Tobias,et al.  A voltage-sensor water pore. , 2006, Biophysical journal.

[38]  F Bezanilla,et al.  The voltage sensor in voltage-dependent ion channels. , 2000, Physiological reviews.

[39]  Berk Hess,et al.  LINCS: A linear constraint solver for molecular simulations , 1997, J. Comput. Chem..

[40]  Wei Zhang,et al.  A point‐charge force field for molecular mechanics simulations of proteins based on condensed‐phase quantum mechanical calculations , 2003, J. Comput. Chem..

[41]  Carsten Kutzner,et al.  GROMACS 4:  Algorithms for Highly Efficient, Load-Balanced, and Scalable Molecular Simulation. , 2008, Journal of chemical theory and computation.

[42]  Yasushi Okamura,et al.  Phosphoinositide phosphatase activity coupled to an intrinsic voltage sensor , 2005, Nature.

[43]  Francisco Bezanilla,et al.  Two atomic constraints unambiguously position the S4 segment relative to S1 and S2 segments in the closed state of Shaker K channel , 2007, Proceedings of the National Academy of Sciences.

[44]  Ehud Y Isacoff,et al.  How does voltage open an ion channel? , 2006, Annual review of cell and developmental biology.

[45]  Benoît Roux,et al.  Closing In on the Resting State of the Shaker K+ Channel , 2007, Neuron.

[46]  E. Kosower,et al.  A structural and dynamic molecular model for the sodium channel of Electrophorus electricus , 1985, FEBS letters.

[47]  L. Loew,et al.  A Fluorometric Approach to Local Electric Field Measurements in a Voltage-Gated Ion Channel , 2003, Neuron.

[48]  C. Jarzynski Nonequilibrium Equality for Free Energy Differences , 1996, cond-mat/9610209.

[49]  H. Guy,et al.  Models of voltage-dependent conformational changes in NaChBac channels. , 2008, Biophysical journal.

[50]  F. Bezanilla,et al.  S4-based voltage sensors have three major conformations , 2008, Proceedings of the National Academy of Sciences.

[51]  F. Sigworth,et al.  Electrostatics and the Gating Pore of Shaker Potassium Channels , 2001, The Journal of general physiology.