An Exact Method for On-line Identification of FOPDT Processes

A new method for on-line process identification and PI controller tuning is proposed. The proposed structure inserts an ideal relay in parallel to a conventional PI controller to induce limit cycle output. The parallel connection of the ideal relay to the PI controller helps in designing a robust controller in presence of static load disturbances in the process. With the limit cycle measurement, a FOPDT transfer function model of the process dynamic is obtained. Based on the identified model, the controller is retuned to achieve good performance without disrupting the closed loop control. The performance of the proposed method is discussed by different simulation results to verify the effectiveness of the proposed method.

[1]  William L. Luyben,et al.  Derivation of transfer functions for highly nonlinear distillation columns , 1987 .

[2]  Kok Kiong Tan,et al.  A modified relay-based technique for improved critical point estimation in process control , 1995, IEEE Trans. Control. Syst. Technol..

[3]  Cheng-Ching Yu,et al.  Derivation of transfer function from relay feedback systems , 1992 .

[4]  Qing-Guo Wang,et al.  Low-Order Modeling from Relay Feedback , 1997 .

[5]  Derek P. Atherton,et al.  An improved parameter estimation method using limit cycle data , 1998 .

[6]  Jiang,et al.  Robust on-line relay automatic tuning of PID control systems , 2000, ISA transactions.

[7]  Tore Hägglund,et al.  Automatic tuning of simple regulators with specifications on phase and amplitude margins , 1984, Autom..

[8]  Lothar Litz,et al.  Relay Based Closed-Loop Tuning of PID Controllers (Adaption der PID-Reglerparameter im geschlossenen Kreis durch Einkopplung eines Zweipunktreglers) , 2004 .

[9]  Tor Steinar Schei,et al.  A method for closed loop automatic tuning of PID controllers , 1992, Autom..

[10]  D. Atherton,et al.  Autotuning and controller design for processes with small time delays , 1999 .

[11]  Tore Hägglund,et al.  Automatic Tuning of Simple Regulators , 1984 .

[12]  Tore Hägglund,et al.  Automatic Tuning of Pid Controllers , 1988 .

[13]  Sunan Huang,et al.  Improved critical point estimation using a preload relay , 2006 .

[14]  Claudio Scali,et al.  Relay with Additional Delay for Identification and Autotuning of Completely Unknown Processes , 1999 .