Robust stereo vision and calibration methodology for accurate three-dimensional digital image correlation measurements on submerged objects

The effect of optical refraction at an interface between optically dissimilar media is modelled in order to apply the principles of three-dimensional digital image correlation (DIC) to measure deformations on submerged objects accurately. Using an analytical formulation for refraction at an interface, a non-linear solution approach is developed to perform stereo calibration. The proposed method incorporates a simplified parametric representation for the orientation and position of an interface(s), accounting explicitly for the effects of refraction at all such interfaces in the path of each stereo camera. Separating the calibration process into two parts, a modified bundle adjustment process with an updated Levenburg—Marquardt (LM) non-linear optimization algorithm is employed to determine (a) intrinsic and extrinsic stereo camera parameters without interface refraction and (b) orientation and position of each planar interface. Detailed simulations demonstrate the efficiency, accuracy, and stability of the methodology when using multiple images of a grid pattern undergoing general rigid body motion, even in the presence of Gaussian noise in the sensor plane measurements, providing a robust framework for practical implementation of the methodology for submerged object measurements.

[1]  K D Moore,et al.  Intercalibration method for underwater three-dimensional mapping laser line scan systems. , 2001, Applied optics.

[2]  João Paulo Costeira,et al.  Stereo Reconstruction of a Submerged Scene , 2005, IbPRIA.

[3]  Jean-Thierry Lapresté,et al.  Dry camera calibration for underwater applications , 2003, Machine Vision and Applications.

[4]  John Watson,et al.  Holography for underwater inspection and measurement: an overview of current work , 1997 .

[5]  M. Sutton,et al.  Effects of subpixel image restoration on digital correlation error estimates , 1988 .

[6]  Donald B. Gennery,et al.  Generalized Camera Calibration Including Fish-Eye Lenses , 2006, International Journal of Computer Vision.

[7]  S M Lessner,et al.  Strain field measurements on mouse carotid arteries using microscopic three-dimensional digital image correlation. , 2008, Journal of biomedical materials research. Part A.

[8]  Young-Hoo Kwon,et al.  Object Plane Deformation Due to Refraction in Two-Dimensional Underwater Motion Analysis , 1999 .

[9]  John Watson,et al.  Underwater hologrammetry: aberrations in the real image of an underwater object when replayed in air , 1988 .

[10]  Yuh J. Chao,et al.  Advances in Two-Dimensional and Three-Dimensional Computer Vision , 2000 .

[11]  Peter R Hobson,et al.  Accurate three-dimensional metrology of underwater objects using replayed real images from in-line and off-axis holograms , 1999 .

[12]  Michael A. Sutton,et al.  Development of a methodology for non-contacting strain measurements in fluid environments using computer vision , 1999 .

[13]  Y. Kwon,et al.  A CAMERA CALIBRATION ALGORITHM FOR THE UNDERWATER MOTION ANALYSIS , 1999 .

[14]  Emanuele Trucco,et al.  Uncalibrated vision for 3-D underwater applications , 1998, IEEE Oceanic Engineering Society. OCEANS'98. Conference Proceedings (Cat. No.98CH36259).

[15]  M. A. Sutton,et al.  Systematic errors in digital image correlation caused by intensity interpolation , 2000 .

[16]  Gábor Horváth,et al.  Underwater binocular imaging of aerial objects versus the position of eyes relative to the flat water surface. , 2003, Journal of the Optical Society of America. A, Optics, image science, and vision.

[17]  Gábor Horváth,et al.  On the structure of the aerial visual field of aquatic animals distorted by refraction , 1991 .

[18]  Michael A. Sutton,et al.  Advances in light microscope stereo vision , 2004 .

[19]  J D Humphrey,et al.  A multiaxial computer-controlled organ culture and biomechanical device for mouse carotid arteries. , 2004, Journal of biomechanical engineering.

[20]  Stephen Tetlow,et al.  Three-dimensional measurement of underwater work sites using structured laser light , 1999 .

[21]  Young-Hoo Kwon,et al.  APPLICABILITY OF FOUR LOCALIZED-CALIBRATION METHODS IN UNDERWATER MOTION ANALYSIS , 2000 .