Hybrid Artificial Cooperative Search – Crow Search Algorithm for Optimization of a Counter Flow Wet Cooling Tower

In this paper, an improved version of Artificial Cooperative Search (ACS) algorithm is applied on a counter flow wet-cooling tower design problem. The Merkel’s method is used to determine the characteristic dimensions of cooling tower, along with empirical correlations for the loss and overall mass transfer coefficients in the packing region of the tower.  Basic perturbation schemes of the Crow Search Algorithm, a recent developed metaheuristic algorithm inspired by the food searching behaviors intelligent crows, are incorporated into ACS to enhance the convergence speed and increase the solution diversity of the algorithm. In order to assess the solution performance of the proposed method, fourteen widely known optimization test function have been solved and corresponding convergence histories has been depicted.  .Then the improved ACS algorithm (IACS) is applied on six different examples of counter flow wet-cooling tower optimization problem. The results obtained by applying the proposed algorithm are compared with the results of some other algorithms in the literature. Optimization results show that IACS is an effective algorithm with rapid convergence performance for the optimization of counter flow wet-cooling towers.

[1]  Pinar Çivicioglu,et al.  Artificial cooperative search algorithm for numerical optimization problems , 2013, Inf. Sci..

[2]  Mehmet Sait Söylemez,et al.  ON THE OPTIMUM SIZING OF COOLING TOWERS , 2001 .

[3]  Detlev G. Kro¨ger,et al.  Cooling tower performance evaluation: Merkel, Poppe, and e-NTU methods of analysis , 2005 .

[4]  Michael Kintner-Meyer,et al.  Cost-optimal design for cooling towers , 1995 .

[5]  Brane Širok,et al.  Improving the efficiency of natural draft cooling towers , 2006 .

[6]  Arturo Jiménez-Gutiérrez,et al.  MINLP optimization of mechanical draft counter flow wet-cooling towers , 2010 .

[7]  A. F. Mills Basic Heat and Mass Transfer , 1999 .

[8]  John B. Shoven,et al.  I , Edinburgh Medical and Surgical Journal.

[9]  Detlev G. Kröger,et al.  Refinement of the Transfer Characteristic Correlation of Wet-Cooling Tower Fills , 2005 .

[10]  R. L. Webb,et al.  A unified theoretical treatment for thermal analysis of cooling towers, evaporative condensers, and fluid coolers , 1984 .

[11]  D. G. Kröger,et al.  Air-cooled heat exchangers and cooling towers , 2005 .

[12]  J. W. Ramsey,et al.  Thermal Environmental Engineering , 1970 .

[13]  Detlev G. Kröger,et al.  Loss coefficient correlation for wet-cooling tower fills , 2003 .

[14]  Hal Gurgenci,et al.  Optimization design of solar enhanced natural draft dry cooling tower , 2013 .

[15]  Jose M. Pinto,et al.  Minimization of Operational Costs in Cooling Water Systems , 2000 .

[16]  M. Boumaza,et al.  Thermal performances investigation of a wet cooling tower , 2007 .

[17]  Phillipp Bergmann Power Plant System Design , 2016 .

[18]  F. N Kemmer,et al.  Nalco water handbook , 1979 .

[19]  Arturo Jiménez-Gutiérrez,et al.  Optimization model for re-circulating cooling water systems , 2010, Comput. Chem. Eng..

[20]  Mi Sandar Mon,et al.  Heat Exchanger Design , 2008 .

[21]  A. K. M. Mohiuddin,et al.  Knowledge base for the systematic design of wet cooling towers. Part I: Selection and tower characteristics , 1996 .

[22]  A. K. M. Mohiuddin,et al.  Knowledge base for the systematic design of wet cooling towers. Part II: Fill and other design parameters , 1996 .

[23]  Michael Kintner-Meyer,et al.  Cost-optimal analysis of cooling towers , 1994 .

[24]  E. Schlunder Heat exchanger design handbook , 1983 .

[25]  Amir A. Al-Haddad,et al.  A Modified Analysis of Counter Flow Wet Cooling Towers , 1997 .

[26]  Detlev G. Kröger,et al.  Cost optimization of cooling tower geometry , 2004 .

[27]  Alireza Askarzadeh,et al.  A novel metaheuristic method for solving constrained engineering optimization problems: Crow search algorithm , 2016 .

[28]  A. Wexler,et al.  FORMULATIONS FOR THE THERMODYNAMIC PROPERTIES OF THE SATURATED PHASES OF H2O FROM 173.15 TO 473.15 K. , 1983 .

[29]  R. V. Rao,et al.  Optimization of mechanical draft counter flow wet-cooling tower using artificial bee colony algorithm , 2011 .

[30]  M. J. Wheeler Heat and Mass Transfer , 1968, Nature.

[31]  Detlev G. Kröger,et al.  A critical investigation into the heat and mass transfer analysis of counterflow wet-cooling towers , 2005 .

[32]  Kuppan Thulukkanam Heat Exchanger Design Handbook , 2013 .