Continuous versus bilevel positive airway pressure for obstructive sleep apnea.

Recent objective studies demonstrate relatively low hours of nightly use during nasal continuous positive airway pressure (CPAP) therapy for obstructive sleep apnea (OSA). Patients frequently complain of dyspnea or discomfort during CPAP use, especially during expiration (against the continuous pressure), which may be a reason for the low hours of use. We hypothesized that with decreased expiratory pressure, hours of nightly use would increase. Therefore, we randomized 83 OSA patients to receive either continuous or bilevel positive airway pressure when expiratory pressure is lower. To document objectively the effective use of either therapy, we built and installed elapsed-time and mask pressure sensors in the patients' positive airway pressure units. A total of 62 patients were evaluable and followed for 1 yr. Of these, 26 received bilevel and 36 CPAP pressures. The machine timers measured accumulated "machine-on" time, and the mask pressure sensor recorded the total time in which the mask pressure was within 2 cm H2O of the effective pressure (pressure shown to eliminate 95% of the obstructive apneas during a full night of polysomnography). The mean machine timer hours of CPAP were 5.0 +/- 0.19 SEM and 4.9 +/- 0.23 SEM during bilevel therapy (p NS) over a 12-mo period. The pressures required during CPAP or bilevel therapy were not different between high and low hourly users. Effective use, the percentage of time that the machine was running and the prescribed pressure was being delivered, was 80% in CPAP and 82% in the bilevel users (p NS). Both groups had equal complaints with regard to mask discomfort, machine noise, and nasal stuffiness.(ABSTRACT TRUNCATED AT 250 WORDS)

[1]  R. Levine Monitoring for adherence: ethical considerations. , 1994, American journal of respiratory and critical care medicine.

[2]  C. Zwillich,et al.  Nasal CPAP: an objective evaluation of patient compliance. , 1994, American journal of respiratory and critical care medicine.

[3]  A I Pack,et al.  Objective measurement of patterns of nasal CPAP use by patients with obstructive sleep apnea. , 1993, The American review of respiratory disease.

[4]  N. Saunders,et al.  Long-term acceptance of continuous positive airway pressure in obstructive sleep apnea. , 1991, The American review of respiratory disease.

[5]  M. Sanders,et al.  Obstructive sleep apnea treated by independently adjusted inspiratory and expiratory positive airway pressures via nasal mask. Physiologic and clinical implications. , 1990, Chest.

[6]  J. Krieger,et al.  Objective measurement of compliance with nasal CPAP treatment for obstructive sleep apnoea syndrome. , 1988, The European respiratory journal.

[7]  R. Rogers,et al.  Patient compliance with nasal CPAP therapy for sleep apnea. , 1986, Chest.

[8]  C. Sullivan,et al.  Remission of severe obesity-hypoventilation syndrome after short-term treatment during sleep with nasal continuous positive airway pressure. , 2015, The American review of respiratory disease.

[9]  ColinE. Sullivan,et al.  REVERSAL OF OBSTRUCTIVE SLEEP APNOEA BY CONTINUOUS POSITIVE AIRWAY PRESSURE APPLIED THROUGH THE NARES , 1981, The Lancet.

[10]  S. Siegel,et al.  Nonparametric Statistics for the Behavioral Sciences , 2022, The SAGE Encyclopedia of Research Design.