Spectral Irradiance and Radiance responsivity Calibrations using Uniform Sources (SIRCUS) facility at NIST

Detectors have historically been calibrated for spectral power responsivity at the National Institute of Standards and Technology (NIST) using a lamp-monochromator system to tune the wavelength of the excitation source. Silicon detectors can be calibrated in the visible spectral region with uncertainties at the 0.1 % level. However, uncertainties increase dramatically when measuring an instrument's spectral irradiance or radiance responsivity. In addition, the uncertainties are even larger in the UV and IR ranges. We will discuss a new laser-based facility for Spectral Irradiance and Radiance responsivity Calibrations using Uniform Sources (SIRCUS) that was developed to calibrate instruments directly in irradiance or radiance mode with uncertainties approaching those available for spectral power responsivity calibrations. In this facility, high-power, tunable lasers are introduced into an integrating sphere using optical fibers, producing uniform, quasi-Lambertian, high radiant flux sources. Reference standard irradiance detectors, calibrated directly against national primary standards for spectral power responsivity, are used to determine the irradiance at a reference plane. Knowing the measurement geometry, the source radiance can be readily determined as well. The radiometric properties of the SIRCUS source coupled with state-of-the-art transfer standard radiometers whose responsivities are directly traceable to primary national radiometric scales, result in typical combined standard uncertainties in irradiance and radiance responsivity calibrations less than 0.1 % in the visible (larger in the UV and IR). Details of the facility are presented and examples of unique calibrations possible in the facility are given, including system-level responsivity calibrations in support of the National Aeronautics and Space Administration's (NASA's) remote sensing activities.

[1]  Steven W. Brown,et al.  Overview of the radiometric calibration of MOBY , 2002, Optics + Photonics.

[2]  N. Fox,et al.  Highly stable, monochromatic and tunable optical radiation source and its application to high accuracy spectrophotometry. , 1992, Applied optics.

[3]  D. Clark,et al.  MOBY, a Radiometric Buoy for Performance Monitoring and Vicarious Calibration of Satellite Ocean Color Sensors: Measurement and Data Analysis Protocols , 2003 .

[4]  James J. Butler,et al.  Radiometric Measurement Comparisons at NASA's Goddard Space Flight Center: Part I. The GSFC Sphere Sources , 2002 .

[5]  G. Thuillier,et al.  The Solar Spectral Irradiance from 200 to 2400 nm as Measured by the SOLSPEC Spectrometer from the Atlas and Eureca Missions , 2003 .

[6]  George P. Eppeldauer,et al.  Opto-Mechanical and Electronic Design of a Tunnel-Trap Si Radiometer , 2000, Journal of research of the National Institute of Standards and Technology.

[7]  C. Wehrli,et al.  Calibrations of filter radiometers for determination of atmospheric optical depth , 2000 .

[8]  A. Smirnov,et al.  AERONET-a federated instrument network and data archive for aerosol Characterization , 1998 .

[9]  Charles E Gibson,et al.  Realization of the National Institute of Standards and Technology detector-based spectral irradiance scale. , 2002, Applied optics.

[10]  George P Eppeldauer,et al.  Facility for spectral irradiance and radiance responsivity calibrations using uniform sources. , 2006, Applied optics.

[11]  Robert Barnes,et al.  Calibration strategy for the Earth Observing System (EOS)-AM1 platform , 1998, IEEE Trans. Geosci. Remote. Sens..

[12]  Steven W. Brown,et al.  NIST facility for Spectral Irradiance and Radiance Responsivity Calibrations with Uniform Sources , 2000 .

[13]  Fry Ga,et al.  Standards and technology. , 1979 .

[14]  Robert Frouin,et al.  Calibration of sun photometers and sky radiance sensors , 2000 .

[15]  Keith Lykke,et al.  Comparison of laser-based and conventional calibrations of sun photometers , 2003, SPIE Optics + Photonics.

[16]  Steven W. Brown,et al.  Radiometric calibration of the Scripps Earth Polychromatic Imaging Camera , 2002, Optics + Photonics.

[17]  Joseph P. Rice An electrically substituted bolometer as a transfer-standard detector , 2000 .

[18]  Steven W. Brown,et al.  Stray-light correction algorithm for spectrographs , 2003 .

[19]  Maritoni Litorja,et al.  Geometric area measurements of circular apertures for radiometry at NIST , 2003 .

[20]  Joseph P. Rice,et al.  The Next Generation of Active Cavity Radiometers for Space-Based Remote Sensing , 1999 .

[21]  Thomas R. Gentile,et al.  Mode-locked lasers for high-accuracy radiometry , 1995 .

[22]  C. Cromer,et al.  National Institute of Standards and Technology high-accuracy cryogenic radiometer. , 1996, Applied optics.

[23]  Thomas R. Gentile,et al.  Realization of a Scale of Absolute Spectral Response using the NIST High Accuracy Cryogenic Radiometer , 1996 .

[24]  James J. Butler,et al.  Radiometric Measurement Comparisons at NASA's Goddard Space Flight Center: Part II. Irradiance Lamp Comparisons and the NIST Sphere Source , 2002 .

[25]  C. Wehrli,et al.  Comparison of Sun photometer calibration by use of the Langley technique and the standard lamp. , 1995, Applied optics.

[26]  P. Moulton Spectroscopic and laser characteristics of Ti:Al2O3 , 1986 .