Torsional balance of plan‐asymmetric structures with frictional dampers: analytical results

This investigation deals with the torsional balance of the earthquake response and design of elastic asymmetric structures with frictional dampers. Plan asymmetry leads to an uneven lateral deformation demand among structural members and to unbalanced designs with larger capacities in some resisting planes. Frictional dampers are capable of controlling lateral‐torsional coupling by placing the so‐called empirical center of balance (ECB) of the structure at equal distance from all edges of the building. This rule is developed for single‐story systems with linear and inelastic behavior. However, recently obtained theoretical and experimental results demonstrate that this rule carries over to multistory structures. Results show that the peak displacement demand at the building edges and that of resisting planes equidistant from the geometric center may be similar if the damper is optimally placed. It is also shown that torsional amplification of the edge displacements of arbitrary asymmetric structures relative to the displacement of the symmetric counterparts are approximately bound by a factor of 2. Furthermore, frictional dampers are equally effective in controlling lateral‐torsional coupling of torsionally flexible as well as stiff structures. Copyright © 2005 John Wiley & Sons, Ltd.

[1]  Cedric Marsh,et al.  Seismic Response of Friction Damped Braced Frames , 1982 .

[2]  Thalia Anagnos,et al.  Slotted Bolted Connections in Aseismic Design for Concentrically Braced Connections , 1989 .

[3]  P. Spanos,et al.  Random vibration and statistical linearization , 1990 .

[4]  Mehmet Çelebi,et al.  Closure of "Method to Estimate Center of Rigidity Using Vibration Recordings" , 1990 .

[5]  O. A. Pekau,et al.  Controlling seismic response of eccentric structures by friction dampers , 1991 .

[6]  Young-Soo Yoon,et al.  Discussion of "Method to Estimate Center of Rigidity Using Vibration Recordings" , 1991 .

[7]  Robert E. Bachman,et al.  The Use of the Energy Dissipating Restraint for Seismic Hazard Mitigation , 1993 .

[8]  Tzong-Shuoh Yang,et al.  Slotted Bolted Connection Energy Dissipators , 1993 .

[9]  Anil K. Chopra,et al.  Understanding the inelastic seismic behaviour of asymmetric-plan buildings , 1995 .

[10]  Rakesh K. Goel,et al.  Effects of supplemental viscous damping on seismic response of asymmetric‐plan systems , 1998 .

[11]  Rakesh K. Goel,et al.  Effects of supplemental viscous damping on inelastic seismic response of asymmetric systems , 2000 .

[12]  Juan Carlos de la Llera,et al.  Three-Dimensional Inelastic Response of an RC Building during the Northridge Earthquake , 2001 .

[13]  Anil K. Chopra,et al.  Understanding and predicting effects of supplemental viscous damping on seismic response of asymmetric one‐storey systems , 2001 .

[14]  J. Kelly,et al.  - 1-SEISMIC RESPONSE OF A NINE-STORY STEEL FRAME WITH FRICTION DAMPED CROSS-BRACING , 2002 .