CFD analysis of pulsatile blood flow in an atherosclerotic human artery with eccentric plaques.

Atherosclerosis is a slow vascular degeneration. It thickens the internal walls of a blood vessel locally depositing an atherosclerotic plaque. Such reduced lumen increases the resistance to blood flow. Plaques can be punctual (eccentric, here considered) or circumferential (symmetrical). Stenoses do not have a typical shape: we hypothesised here a reference geometry (trapezium) with its possible evolutions (semi-ellipse, triangle). Two criteria (Equivalent Area and Equivalent Dimensions) were then defined to compare the results among the 35 case studies numerically analysed with a Computational Fluid Dynamics code (Comsol Multiphysics 3.3). Blood was considered a Cassonian fluid with modified viscosity equation. The artery was cylindrical, rigid and straight, interested by a pulsatile blood flow. Among the variables: shape and dimensions of the stenoses; number of stenoses (single or coupled pathologies); mutual locations (3 possibilities). The main results were that the length of the consequent flow disturbance is due to the stenotic shape and height; blood flow recirculation, downstream of the pathology, is due to the slope of the stenotic walls; and the peak velocities depend on the shape and height of stenosis. The differences from case to case diminish in diastole.

[1]  G. Thurston,et al.  Rheological parameters for the viscosity viscoelasticity and thixotropy of blood. , 1979, Biorheology.

[2]  Viale Risorgimento,et al.  A numerical study of the flow disturbance caused by an intravascular Doppler catheter in a blood vessel , 1998 .

[3]  Jie Zheng,et al.  Effect of Stenosis Asymmetry on Blood Flow and Artery Compression: A Three-Dimensional Fluid-Structure Interaction Model , 2003, Annals of Biomedical Engineering.

[4]  A. Jeremias,et al.  Spatial orientation of atherosclerotic plaque in non-branching coronary artery segments. , 2000, Atherosclerosis.

[5]  E. Balaras,et al.  A numerical and experimental investigation of transitional pulsatile flow in a stenosed channel. , 2005, Journal of biomechanical engineering.

[6]  N. Casson,et al.  A flow equation for pigment-oil suspensions of the printing ink type , 1959 .

[7]  Takami Yamaguchi,et al.  Clinical Application of Computational Mechanics to the Cardiovascular System , 2013, Springer Japan.

[8]  M. Zamir The Physics of Coronary Blood Flow , 2005 .

[9]  Steven H Frankel,et al.  Numerical modeling of pulsatile turbulent flow in stenotic vessels. , 2003, Journal of biomechanical engineering.

[10]  Nelson O. Moraga,et al.  On predicting unsteady non-Newtonian blood flow , 2005, Appl. Math. Comput..

[11]  Panagiotis Neofytou,et al.  Non-Newtonian flow instability in a channel with a sudden expansion , 2003 .

[12]  M. Fishbein,et al.  Highly localized arterial remodeling in patients with coronary atherosclerosis: an intravascular ultrasound study. , 1997, Circulation.

[13]  A. Yoganathan,et al.  Biofluid Mechanics: The Human Circulation , 2006 .

[14]  H N Sabbah,et al.  Patterns of flow in the left coronary artery. , 1984, Journal of biomechanical engineering.

[15]  P. Hoskins,et al.  Numerical investigation of physiologically realistic pulsatile flow through arterial stenosis. , 2001, Journal of biomechanics.

[16]  D. Ku BLOOD FLOW IN ARTERIES , 1997 .

[17]  K. W. Lee,et al.  Modelling of flow and wall behaviour in a mildly stenosed tube. , 2002, Medical engineering & physics.

[18]  V. Fuster,et al.  Coronary plaque disruption. , 1995, Circulation.

[19]  S. Sherwin,et al.  Numerical simulation of pulsatile flow through stenotic vessels of different local morphologies , 2002, Proceedings of the Second Joint 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society] [Engineering in Medicine and Biology.

[20]  Giulio Lorenzini Blood velocity field numerical assessment using a GPL code in case of intravascular Doppler catheter affections: comparative analysis of different rheological models. , 2005, Journal of biomechanics.

[21]  K. Moser,et al.  Velocity measurements of flow through a step stenosis using Magnetic Resonance Imaging , 2000 .