Dynamic characteristics of a PEM fuel cell system for individual houses

The method of determination of the control variables for a system controller, which controls the electric power output of a solid-polymer-membrane (PEM) fuel cell system during electric power load fluctuations, was considered. The operation was clarified for the response characteristics of electric power generation for setting the control variables of proportional action and integral action considered to be the optimal for the system controller. The power load pattern of an individual house consists of loads usually moved up and down rapidly for a short time. Until now, there have been no examples showing the characteristics of the power generation efficiency of a system that follows a load pattern that moves up and down rapidly. Therefore, this paper investigates the relation of the control variables and power generation efficiency when adding change that simulates the load of a house to PEM fuel cell cogeneration. As a result, it was shown that an operation, minimally influenced by load fluctuations, can be performed by changing the control variables using the value of the electric power load of a system. Copyright © 2006 John Wiley & Sons, Ltd.