Study of Optic Nerve Sheath Diameter in Normal Nepalese Adults Using Ultrasound

Introduction: Though invasive intracranial devices are gold standard to calculate intracranial pressure (ICP); these are not without any complications. Non-invasive measurement of ICP by Ultrasonography could be a safe and portable technique.Objectives: The objective of the study was to measure and compare values of optic nerve sheath diameter of both eyes in healthy Nepalese adults.Methodology: A prospective cross-sectional study of healthy adult Nepalese volunteers was performed using a 7.5 MHz linear Ultrasound probe on the closed eyelids; optic nerve sheath diameter (ONSD) was measured 3 mm behind the globe in each eye.Results: Optic nerve sheath diameter (ONSD) of both eyes was measured in 100 healthy volunteers of age ranged from 15 to 75 years with a mean of 30.21 ± 14.05 years. There were 18 (18%) male and 82 (82%) female. ONSD for right eye ranged from 3.20 to 4.90 mm with mean of 4.10 ± 0.50 mm and left eye from 3.20 to 4.80 mm with mean of 4.22 ± 0.49 mm. P value for right and left eye ONSD (P = 0.06) and male and female (P = 0.12 and 0.85 for right and left ONSD respectively) were within normal limits. ONSD has no correlation with age (P = 0.27 and 0.27 for right and left ONSD respectively).Conclusion Mean of optic nerve sheath diameter (ONSD) is 4.10mm and 4.22 mm for right and left eye respectively. There is no statistical significant difference in mean of ONSD between right and left eye. BJHS 2018;3(1)5 : 357-360

[1]  Ian Piper,et al.  Monitoring of Intracranial Pressure in Patients with Traumatic Brain Injury , 2014, Front. Neurol..

[2]  A. Noyce,et al.  Cranial nerves , 2008, The Finalist’s Guide to Passing the OSCE.

[3]  R. Maude,et al.  Transorbital Sonographic Evaluation of Normal Optic Nerve Sheath Diameter in Healthy Volunteers in Bangladesh , 2013, PloS one.

[4]  P. Stieg,et al.  Intracranial pressure is still number 1 despite BEST:TRIP study. , 2013, World neurosurgery.

[5]  N. Carney,et al.  A trial of intracranial-pressure monitoring in traumatic brain injury. , 2012, The New England journal of medicine.

[6]  Jeffrey J. Fletcher,et al.  Comparison of accuracy of optic nerve ultrasound for the detection of intracranial hypertension in the setting of acutely fluctuating vs stable intracranial pressure: post-hoc analysis of data from a prospective, blinded single center study , 2012, Critical Care.

[7]  M. Kaps,et al.  Intra‐ and Interobsever Reliability of Sonographic Assessment of the Optic Nerve Sheath Diameter in Healthy Adults , 2012, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[8]  A. Boyle,et al.  Ultrasound measurement of optic nerve sheath diameter in patients with a clinical suspicion of raised intracranial pressure , 2010, Emergency Medicine Journal.

[9]  D. Agrawal,et al.  Delayed rise in intracranial pressure in patients with head injury , 2010, Indian Journal of Neurotrauma.

[10]  Eric Bershad1,et al.  Intracranial Hypertension , 2008, Seminars in neurology.

[11]  T. Geeraerts,et al.  Ocular sonography for the detection of raised intracranial pressure , 2008 .

[12]  P. Chan,et al.  Transorbital Sonographic Evaluation of Optic Nerve Sheath Diameter in Normal Hong Kong Chinese Adults , 2008 .

[13]  Giuseppe Citerio,et al.  NICEM consensus on neurological monitoring in acute neurological disease , 2008, Intensive Care Medicine.

[14]  N. Stocchetti Could intracranial pressure in traumatic brain injury be measured or predicted noninvasively? Almost , 2007, Intensive Care Medicine.

[15]  L. Steiner,et al.  Monitoring the injured brain: ICP and CBF. , 2006, British journal of anaesthesia.

[16]  M. Blaivas,et al.  Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath. , 2003, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[17]  A. Hollman,et al.  Observer variation in the sonographic measurement of optic nerve sheath diameter in normal adults. , 2002, European journal of ultrasound : official journal of the European Federation of Societies for Ultrasound in Medicine and Biology.

[18]  H. Lee,et al.  Normative measurements of Korean orbital structures revealed by computerized tomography. , 2001, Acta ophthalmologica Scandinavica.

[19]  G. Dutton,et al.  Transorbital optic nerve sheath ultrasonography in normal children. , 1999, Clinical radiology.

[20]  H. Hansen,et al.  Validation of the optic nerve sheath response to changing cerebrospinal fluid pressure: ultrasound findings during intrathecal infusion tests. , 1997, Journal of neurosurgery.

[21]  A. Hussain,et al.  Optic nerve sheath diameter evaluated by transorbital sonography in healthy volunteers from Pakistan , 2015 .

[22]  T. Mattei Intracranial pressure monitoring in severe traumatic brain injury: who is still bold enough to keep sinning against the level I evidence? , 2013, World neurosurgery.

[23]  S. Wahab,et al.  Role of Transcranial Doppler and Pressure Provocation in Evaluation of Cerebral Compliance in Children with Hydrocephalus , 2008 .

[24]  A. Agrawal,et al.  INTRACRANIAL PRESSURE MONITORING: CONCEPTS IN EVALUATION AND MEASUREMENT , 2007 .

[25]  David W Wright,et al.  Guidelines for the management of severe traumatic brain injury. VII. Intracranial pressure monitoring technology. , 2007, Journal of neurotrauma.

[26]  H. Hansen,et al.  Fundamentals of transorbital sonographic evaluation of optic nerve sheath expansion under intracranial hypertension , 2005, Pediatric Radiology.

[27]  S. Boniface,et al.  Raised intracranial pressure and seizures in the neurological intensive care unit. , 2003, British journal of anaesthesia.

[28]  M. Ball,et al.  Normal Computed Tomograms in Acute Head Injury , 1982 .