Operational verification of a 40-MHz annular array transducer

An experimental system to take advantage of the imaging capabilities of a 5-ring polyvinylidene fluoride (PVDF)-based annular array is presented. The array has a 6-mm total aperture and a 12-mm geometric focus. The experimental system is designed to pulse a single element of the array and then digitize the received data of all array channels simultaneously. All transmit/receive pairs are digitized and then the data are post-processed with a synthetic-focusing technique to achieve an enhanced depth of field (DOF). The performance of the array is experimentally tested with a wire phantom consisting of 25-mum diameter wires diagonally spaced at 1-mm by 1-mm intervals. The phantom permitted the efficacy of the synthetic-focusing algorithm to be tested and was also used for two-way beam characterization. Experimental results are compared to a spatial impulse response method beam simulation. After synthetic focusing, the two-way echo amplitude was enhanced over the range of 8 to 19 mm and the 6-dB DOF spanned from 9 to 15 mm. For a wire at a fixed axial depth, the relative time delays between transmit/receive ring pairs agreed with theoretical predictions to within plusmn2 ns. To further test the system, B-mode images of an excised bovine eye were rendered

[1]  D. A. Christopher,et al.  Advances in ultrasound biomicroscopy. , 2000, Ultrasound in medicine & biology.

[2]  F. Foster,et al.  The design and fabrication of high frequency poly(vinylidene fluoride) transducers. , 1989, Ultrasonic imaging.

[3]  D. Turnbull,et al.  Design and fabrication of a 40-MHz annular array transducer , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[4]  K. Shung,et al.  A 35 MHz linear ultrasonic array for medical imaging , 2002, Proceedings of the 13th IEEE International Symposium on Applications of Ferroelectrics, 2002. ISAF 2002..

[5]  D J Coleman,et al.  Three-dimensional high-frequency ultrasonic parameter imaging of anterior segment pathology. , 1995, Ophthalmology.

[6]  N Bom,et al.  Characterization of plaque components and vulnerability with intravascular ultrasound elastography. , 2000, Physics in medicine and biology.

[7]  G. R. Lockwood,et al.  Design of a 40 MHz annular array , 2001, 2001 IEEE Ultrasonics Symposium. Proceedings. An International Symposium (Cat. No.01CH37263).

[8]  Timothy A. Ritter,et al.  High-frequency single-element and annular array transducers incorporating PVDF , 2000, Medical Imaging.

[9]  K. Shung,et al.  A 30-MHz piezo-composite ultrasound array for medical imaging applications , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[10]  M Arditi,et al.  An annular array system for high resolution breast echography. , 1982, Ultrasonic imaging.

[11]  S.L. Garverick,et al.  Unit-delay focusing architecture and integrated-circuit implementation for high-frequency ultrasound , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[12]  D. A. Christopher,et al.  40-MHZ echocardiography scanner for cardiovascular assessment of mouse embryos. , 1998, Ultrasound in medicine & biology.

[13]  F. S. Foster,et al.  Beyond 30 MHz [applications of high-frequency ultrasound imaging] , 1996 .

[14]  Carlos H. F. Alves,et al.  Design, fabrication, and evaluation of high frequency, single-element transducers incorporating different materials , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  G.R. Lockwood,et al.  Design and fabrication of annular arrays for high-frequency ultrasound , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  L From,et al.  A 40-100 MHz B-scan ultrasound backscatter microscope for skin imaging. , 1995, Ultrasound in medicine & biology.

[17]  F. Stuart Foster,et al.  In vivo ultrasound biomicroscopy in developmental biology , 2002 .

[18]  K. Raum,et al.  Pulse-echo field distribution measurement technique for high-frequency ultrasound sources , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[19]  F. Stuart Foster,et al.  Transient Fields of Concave Annular Arrays , 1981 .

[20]  F. Foster,et al.  Fabrication of high frequency spherically shaped ceramic transducers , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[21]  Daniel H Turnbull,et al.  Ultrasound biomicroscopy-Doppler in mouse cardiovascular development. , 2003, Physiological genomics.

[22]  K. Shung,et al.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.