Characterization of a Silicon Strip Detector and a YAG:Ce Calorimeter for a Proton Computed Radiography Apparatus

Today, there is a steadily growing interest in the use of proton beams for tumor therapy, as they permit to tightly shape the dose delivered to the target reducing the exposure of the surrounding healthy tissues. Nonetheless, accuracy in the determination of the dose distribution in proton-therapy is up to now limited by the uncertainty in stopping powers, which are presently calculated from the photon attenuation coefficients measured by X-ray tomography. Proton computed tomography apparatus (pCT) has been proposed to directly measure the stopping power and reduce this uncertainty. Main problem with proton imaging is the blurring effect introduced by multiple Coulomb scattering: single proton tracking is a promising technique to face this difficulty. As a first step towards a pCT system, we designed a proton radiography (pCR) prototype based on a silicon microstrip tracker (to characterize particle trajectories) and a segmented YAG:Ce calorimeter (to measure their residual energy). Aim of the system is to detect protons with a ~1 MHz particle rate of and with kinetic energy in the range 250-270 MeV, high enough to pass through human body. Design and development of the pCR prototype, as well as the characterization of its single components, are described in this paper.

[1]  E. Pedroni,et al.  The calibration of CT Hounsfield units for radiotherapy treatment planning. , 1996, Physics in medicine and biology.

[2]  S. Peggs,et al.  Conceptual design of a proton computed tomography system for applications in proton radiation therapy , 2004, IEEE Transactions on Nuclear Science.

[3]  P Zygmanski,et al.  The measurement of proton stopping power using proton-cone-beam computed tomography. , 2000, Physics in medicine and biology.

[4]  Zhengrong Liang,et al.  Reconstruction for proton computed tomography by tracing proton trajectories: a Monte Carlo study. , 2006, Medical physics.

[5]  E. Ables,et al.  An 800-MeV proton radiography facility for dynamic experiments , 1998 .

[6]  A. Seiden,et al.  Toward proton computed tomography , 2002, IEEE Transactions on Nuclear Science.

[7]  V. Bashkirovb,et al.  Issues in Proton Computed Tomography , 2003 .

[8]  M. Glas,et al.  Principles of Computerized Tomographic Imaging , 2000 .

[9]  J. E. Moyal XXX. Theory of ionization fluctuations , 1955 .

[10]  J. Ziegler,et al.  The stopping of ions in compounds , 1988 .

[11]  J. de Boer,et al.  A detector system for proton radiography on the gantry of the Paul-Scherrer-Institute ☆ , 1999 .

[12]  Cinzia Talamonti,et al.  The Italian project for a proton imaging device , 2007 .

[13]  G. Cuttone,et al.  Monte Carlo Studies of a Proton Computed Tomography System , 2007, IEEE Transactions on Nuclear Science.

[14]  Kenneth M. Hanson,et al.  Proton Computed Tomography , 1979, IEEE Transactions on Nuclear Science.

[15]  H. Sadrozinski,et al.  Initial studies on proton computed tomography using a silicon strip detector telescope , 2003 .

[16]  E Pedroni,et al.  Multiple Coulomb scattering and spatial resolution in proton radiography. , 1994, Medical physics.

[17]  Manjit Dosanjh,et al.  Status of hadron therapy in Europe and the role of ENLIGHT , 2007 .

[18]  A M Koehler,et al.  Proton Beam Radiography in Tumor Detection , 1973, Science.

[19]  G. Cuttone,et al.  Prototype Tracking Studies for Proton CT , 2007, IEEE Transactions on Nuclear Science.

[20]  Barbara Kaser-Hotz,et al.  First proton radiography of an animal patient. , 2004, Medical physics.

[21]  D. Williams,et al.  The most likely path of an energetic charged particle through a uniform medium. , 2004, Physics in medicine and biology.