A motion transmission model for multi-DOF tendon-driven mechanisms with hysteresis and coupling: Application to a da Vinci® instrument

Tendon-driven mechanisms used in robotic surgery exhibit strong nonlinearities, particularly a static backlash-like hysteresis, in their motion transmission behavior. In this paper, an extension of a previously developed model is proposed that allows for estimation of angular displacements in multi-DOF tendon-driven devices where special attention is given to the coupling effect between DOFs. The proposed model consists of the conventional coupling matrix and a novel elongation matrix which compensates for the coupled hysteretic effect. The model is applied to the problem of position estimation in three DOFs (one pitch and two grasping DOFs) of a da Vinci® surgical instrument. As a further extension, a preliminary dynamic model is also suggested to deal with high-frequency inputs. According to the experimental results obtained, the proposed quasi-static model can describe the transmission behavior with goodness-of-fit of 76–92 per cent, and the estimates are improved by 35–72 per cent in terms of the RMSE for the proposed dynamic model as compared to the conventional rigid model.

[1]  Rajnikant V. Patel,et al.  Quasi-static modeling of the da Vinci instrument , 2014, 2014 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[2]  L Kong,et al.  Microslip friction in flat belt drives , 2005 .

[3]  Blake Hannaford,et al.  Improving position precision of a servo-controlled elastic cable driven surgical robot using Unscented Kalman Filter , 2015, 2015 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS).

[4]  M. Bergamasco,et al.  Dynamic modelling of a class of tendon driven manipulators , 1997, 1997 8th International Conference on Advanced Robotics. Proceedings. ICAR'97.

[5]  Vincent Hayward,et al.  Parameter Sensitivity Analysis for Design and Control of Tendon Transmissions , 1995, ISER.

[6]  A. E. Traver,et al.  Multipulley Belt Drive Mechanics: Creep Theory vs Shear Theory , 1995 .

[7]  Blake Hannaford,et al.  Robustness of the Unscented Kalman filter for state and parameter estimation in an elastic transmission , 2009, Robotics: Science and Systems.

[8]  Hiroaki Kobayashi,et al.  On Tendon-Driven Robotic Mechanisms with Redundant Tendons , 1998, Int. J. Robotics Res..

[9]  Alexander H. Slocum,et al.  Theoretical and experimental determination of capstan drive stiffness , 2007 .

[10]  Rajni V. Patel,et al.  A Dual-Arm 7-Degrees-of-Freedom Haptics-Enabled Teleoperation Test Bed for Minimally Invasive Surgery , 2014 .

[11]  Rajnikant V. Patel,et al.  Tissue compliance determination using a da Vinci instrument , 2015, 2015 IEEE International Conference on Robotics and Automation (ICRA).

[12]  Blake Hannaford,et al.  Unscented Kalman Filter and 3D vision to improve cable driven surgical robot joint angle estimation , 2016, 2016 IEEE International Conference on Robotics and Automation (ICRA).