Performance analysis of phase-change material storage unit for both heating and cooling of buildings

Utilisation of solar energy and the night ambient (cool) temperatures are the passive ways of heating and cooling of buildings. Intermittent and time-dependent nature of these sources makes thermal energy storage vital for efficient and continuous operation of these heating and cooling techniques. Latent heat thermal energy storage by phase-change materials (PCMs) is preferred over other storage techniques due to its high-energy storage density and isothermal storage process. The current study was aimed to evaluate the performance of the air-based PCM storage unit utilising solar energy and cool ambient night temperatures for comfort heating and cooling of a building in dry-cold and dry-hot climates. The performance of the studied PCM storage unit was maximised when the melting point of the PCM was ∼29°C in summer and 21°C during winter season. The appropriate melting point was ∼27.5°C for all-the-year-round performance. At lower melting points than 27.5°C, declination in the cooling capacity of the storage unit was more profound as compared to the improvement in the heating capacity. Also, it was concluded that the melting point of the PCM that provided maximum cooling during summer season could be used for winter heating also but not vice versa.

[1]  Adeel Waqas,et al.  Utilization of Latent Heat Storage Unit for Comfort Ventilation of Buildings in Hot and Dry Climates , 2011 .

[2]  R. Velraj,et al.  Parametric studies on packed bed storage unit filled with PCM encapsulated spherical containers for low temperature solar air heating applications , 2014 .

[3]  Aref Y. Maalej,et al.  Dynamic modelling and simulation of a new air conditioning prototype by solar energy , 2007 .

[4]  Jiang Yi,et al.  Modeling and experimental study on an innovative passive cooling system—NVP system , 2003 .

[5]  Angelika Bayer,et al.  Solar Engineering Of Thermal Processes , 2016 .

[6]  K. S. Ong Thermal performance of solar air heaters: Mathematical model and solution procedure , 1995 .

[7]  Francesco Calise,et al.  Transient analysis and energy optimization of solar heating and cooling systems in various configurations , 2010 .

[8]  Nasrudin Abd Rahim,et al.  Review of PCM based cooling technologies for buildings , 2012 .

[9]  Uroš Stritih,et al.  Energy saving in building with PCM cold storage , 2007 .

[10]  Zia Ud Din,et al.  Phase change material (PCM) storage for free cooling of buildings—A review , 2013 .

[11]  Wasim Saman,et al.  Validation of a mathematical model for encapsulated phase change material flat slabs for cooling applications , 2011 .

[12]  E. Lavernia,et al.  An experimental investigation , 1992, Metallurgical and Materials Transactions A.

[13]  Maciej Jaworski,et al.  Thermal performance of building element containing phase change material (PCM) integrated with ventilation system – An experimental study , 2014 .

[14]  Uroš Stritih,et al.  Experimental investigation of PCM cold storage , 2009 .

[15]  F. Nicol Adaptive thermal comfort standards in the hot–humid tropics , 2004 .

[16]  D. Asimakopoulos Passive Cooling of Buildings , 1996 .

[17]  Wasim Saman,et al.  Thermal performance of PCM thermal storage unit for a roof integrated solar heating system , 2005 .

[18]  Martin Belusko,et al.  Roof integrated solar heating system with glazed collector , 2004 .

[19]  Xin Wang,et al.  Energy-Efficient Building Envelopes with Phase-Change Materials: New Understanding and Related Research , 2014 .

[20]  Michael A. Humphreys,et al.  ADAPTIVE THERMAL COMFORT AND SUSTAINABLE THERMAL STANDARDS FOR BUILDINGS , 2002 .

[21]  J. J. Jurinak,et al.  Sizing phase-change energy storage units for air-based solar heating systems , 1979 .

[22]  Qunli Zhang,et al.  Performance of a hybrid heating system with thermal storage using shape-stabilized phase-change material plates , 2007 .

[23]  Baruch Givoni,et al.  Options and applications of passive cooling , 1984 .

[24]  Viorel Badescu,et al.  Renewable energy for passive house heating: Model of the active solar heating system , 2006 .

[25]  Adeel Waqas,et al.  Phase Change Material (Pcm)-Based Solar Air Heating System For Residential Space Heating In Winter , 2013 .

[26]  L. Cabeza,et al.  Free-cooling of buildings with phase change materials , 2004 .

[27]  Adeel Waqas,et al.  Thermal performance of latent heat storage for free cooling of buildings in a dry and hot climate: A , 2011 .

[28]  K. A. Antonopoulos,et al.  Parametric analysis of space cooling systems based on night ceiling cooling with PCM‐embedded piping , 2012 .

[29]  E. Halawa,et al.  Thermal performance analysis of a phase change thermal storage unit for space heating , 2011 .

[30]  Sašo Medved,et al.  Free cooling of a building using PCM heat storage integrated into the ventilation system , 2007 .

[31]  Shuli Liu,et al.  A work procedure of utilising PCMs as thermal storage systems based on air-TES systems , 2014 .

[32]  William A. Beckman,et al.  Solar Engineering of Thermal Processes, 2nd ed. , 1994 .

[33]  Aris Tsangrassoulis,et al.  On the cooling potential of night ventilation techniques in the urban environment , 2005 .

[34]  Wasim Saman,et al.  Analysis and modelling of a phase change storage system for air conditioning applications , 2001 .

[35]  Wei Sun,et al.  Experiment and prediction of hybrid solar air heating system applied on a solar demonstration building , 2014 .

[36]  Transonic Resonance,et al.  Experimental Investigation of , 2001 .

[37]  Wasim Saman,et al.  Numerical analysis of a PCM thermal storage system with varying wall temperature , 2005 .

[38]  David Infield,et al.  Thermal modelling of a building with an integrated ventilated PV façade , 2003 .

[39]  Martin Belusko,et al.  Minimising energy usage for domestic cooling with off-peak PCM storage , 2014 .

[40]  M. Cross,et al.  Accurate solutions of moving boundary problems using the enthalpy method , 1981 .

[41]  L. Cabeza,et al.  Experimental evaluation of commercial heat exchangers for use as PCM thermal storage systems , 2009 .

[42]  David Infield,et al.  A simplified approach to thermal performance calculation for building integrated mechanically ventilated PV facades , 2006 .

[43]  Göran Hed,et al.  Mathematical modelling of PCM air heat exchanger , 2006 .

[44]  B. Givoni Passive and Low Energy Cooling of Buildings , 1994 .

[45]  Sašo Medved,et al.  Correlation between the local climate and the free-cooling potential of latent heat storage , 2008 .