Real-Time Monitoring of Post-Surgical and Post-Traumatic Eye Injuries Using Multilayered Electrical Biosensor Chip.

Lack of current techniques for the early monitoring of bleb leaks and other post-traumatic or post-surgical ocular injury has posed an unmet clinical need for the development of new techniques. Present evaluation techniques use either subjective or nonquantitative approaches. At present, there are no FDA approved ocular devices that can directly measure ascorbic acid (AA) concentration levels for both tear film (TF) and aqueous humor (AH) at point-of-care (POC) level. Toward this aim, we present a novel POC quantitative assay, called the ocular biosensor device, which can be used to evaluate the integrity of the anterior surface of the eye by measuring the concentration of AA in TF and AH. Herein, we utilize a novel scientific engineering approach for the development of a disposable paper based POC ocular biosensor strip. A grafted poly(styrene)-block-poly(acrylic acid) (PS-b-PAA) and graphene platelet composite with contour based μ-electrodes design (CBμE) exhibit a highly sensitive platform to perform electrochemical immunosensing technique to study clinical samples that have small volumes like tear fluid. Samples used in this study were collected clinically from subjects undergoing therapeutic anterior chamber paracentesis. The proposed biosensor reports the level of AA concentration on an electronic screen, making the results easy to read, efficient, and reliable.

[1]  I. Brener,et al.  Simultaneous Detection of Dopamine, Ascorbic Acid and Uric Acid at Lithographically‐Defined 3D Graphene Electrodes , 2014 .

[2]  Joe Hodkiewicz,et al.  Characterizing Carbon Materials with Raman Spectroscopy , 2010 .

[3]  Anne Claire Dupuis,et al.  The catalyst in the CCVD of carbon nanotubes—a review , 2005 .

[4]  Vojtech Adam,et al.  Determination of Vitamin C (Ascorbic Acid) Using High Performance Liquid Chromatography Coupled with Electrochemical Detection , 2008, Sensors.

[5]  D. Musch,et al.  Postoperative endophthalmitis associated with sutured versus unsutured clear corneal cataract incisions , 2007, British Journal of Ophthalmology.

[6]  L Avigliano,et al.  Refined crystal structure of ascorbate oxidase at 1.9 A resolution. , 1992, Journal of molecular biology.

[7]  Theodore Leng,et al.  DELAYED-ONSET BLEB-ASSOCIATED ENDOPHTHALMITIS (1996–2008): Causative Organisms and Visual Acuity Outcomes , 2011, Retina.

[8]  Deana McDonagh,et al.  Empathic design: Research strategies. , 2013, The Australasian medical journal.

[9]  M. Pavão,et al.  Rapid, sensitive and simultaneous determination of ascorbic and uric acids in human plasma by ion-exclusion HPLC-UV. , 2013, Clinical biochemistry.

[10]  S. Richer,et al.  Tear fluid content of electrochemically active components including water soluble antioxidants. , 1998, Current eye research.

[11]  H. Bresson-Dumont,et al.  Réfection de bulle de filtration après chirurgie du glaucome. Résultats tonométriques à moyen terme , 2009 .

[12]  T. Moeslinger,et al.  Spectrophotometric determination of ascorbic acid and dehydroascorbic acid. , 1995, Clinical chemistry.

[13]  Quantitation of Peptides and Amino Acids with a SynergyTMHT using UV Fluorescence , 2006 .

[14]  P Cho,et al.  Ascorbic acid concentration and total antioxidant activity of human tear fluid measured using the FRASC assay. , 2000, Investigative ophthalmology & visual science.

[15]  Leanne T. Labriola,et al.  Point-of-service, quantitative analysis of ascorbic acid in aqueous humor for evaluating anterior globe integrity , 2015, Scientific Reports.

[16]  C. Kaufmann,et al.  Corneal Patch Graft for the Repair of Late-onset Hypotony or Filtering Bleb Leak After Trabeculectomy: A New Surgical Technique , 2014, Journal of glaucoma.

[17]  S. Jagota,et al.  A new colorimetric technique for the estimation of vitamin C using Folin phenol reagent. , 1982, Analytical biochemistry.

[18]  Emily W. Gower,et al.  Standardized Seidel test to evaluate different sutureless cataract incision configurations , 2010, Journal of cataract and refractive surgery.

[19]  R. Braun Dynamics of the Tear Film , 2012 .

[20]  Motoaki Yoshida,et al.  Intraocular pressure and wound status in eyes immediately after scleral tunnel incision and clear corneal incision cataract surgery. , 2014, American journal of ophthalmology.

[21]  Z. Zainal,et al.  Voltammetry detection of ascorbic acid at glassy carbon electrode modified by single-walled carbon nanotube/zinc oxide. , 2013 .

[22]  Yusran Sulaiman,et al.  Simultaneous Electrochemical Detection of Dopamine and Ascorbic Acid Using an Iron Oxide/Reduced Graphene Oxide Modified Glassy Carbon Electrode , 2014, Sensors.

[23]  K. Jagannadham Electrical conductivity of copper–graphene composite films synthesized by electrochemical deposition with exfoliated graphene platelets , 2012 .

[24]  R. Packard,et al.  Adherent ocular bandage for clear corneal incisions used in cataract surgery , 2010, Journal of cataract and refractive surgery.

[25]  Chen-zhong Li,et al.  Simultaneous detection of dopamine, ascorbic acid, and uric acid at electrochemically pretreated carbon nanotube biosensors. , 2010, Nanomedicine : nanotechnology, biology, and medicine.

[26]  M. T. Leite,et al.  Ascorbic acid concentration is reduced in the secondary aqueous humour of glaucomatous patients , 2009, Clinical & experimental ophthalmology.

[27]  F. Holly,et al.  Tear film physiology. , 1980, American journal of optometry and physiological optics.

[28]  H. Flynn,et al.  Delayed-onset bleb-associated endophthalmitis: clinical features and visual acuity outcomes. , 2002, Ophthalmology.

[29]  S. Schneider,et al.  Liquid bandage (2-octyl cyanoacrylate) as a temporary wound barrier in clear corneal cataract surgery. , 2005, Ophthalmology.

[30]  A. Kijlstra,et al.  Inhibition of hydroxyl radical formation by human tears. , 1987, Investigative ophthalmology & visual science.

[31]  P. Drábková,et al.  The determination of ascorbic acid and uric acid in human seminal plasma using an HPLC with UV detection. , 2011, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[32]  R. Mahajan,et al.  Electrochemical detection of dopamine in the presence of ascorbic acid using graphene modified electrodes. , 2010, Biosensors & bioelectronics.

[33]  C. Paterson,et al.  Vitamin C levels in human tears. , 1987, Archives of ophthalmology.

[34]  Tara L Loyd,et al.  Outcomes and bleb-related complications of trabeculectomy. , 2012, Ophthalmology.

[35]  Chia-Liang Sun,et al.  The simultaneous electrochemical detection of ascorbic acid, dopamine, and uric acid using graphene/size-selected Pt nanocomposites. , 2011, Biosensors & bioelectronics.

[36]  G. Trope,et al.  Buccal Mucous Membrane for the Reconstruction of Complicated Leaking Trabeculectomy Blebs , 2009, Journal of glaucoma.

[37]  Quantitative analysis of tear film fluorescence and discomfort during tear film instability and thinning. , 2013, Investigative ophthalmology & visual science.

[38]  A. Tarkkanen,et al.  Effects of the Schirmer test on the fibrinolytic system in the tear fluid. , 1990, Experimental eye research.

[39]  Cao Chen,et al.  Melt blending in situ enhances the interaction between polystyrene and graphene through π-π stacking. , 2011, ACS applied materials & interfaces.

[40]  J. Kirwan,et al.  Trabeculectomy in the 21st century: a multicenter analysis. , 2013, Ophthalmology.

[41]  B. Satpati,et al.  Simultaneous and sensitive determination of ascorbic acid, dopamine, uric acid, and tryptophan with silver nanoparticles-decorated reduced graphene oxide modified electrode. , 2013, Colloids and surfaces. B, Biointerfaces.

[42]  Tetsuya Yamamoto,et al.  Blindness following bleb-related infection in open angle glaucoma , 2014, Japanese Journal of Ophthalmology.

[43]  J. B. Soltau,et al.  Glaucoma-filtering bleb infections. , 2003, Current opinion in ophthalmology.

[44]  B. Krajewska,et al.  Enzyme immobilization by adsorption: a review , 2014, Adsorption.

[45]  Ronald Klein,et al.  The prevalence of age-related eye diseases and visual impairment in aging: current estimates. , 2013, Investigative ophthalmology & visual science.

[46]  Guobao Xu,et al.  Simultaneous electrochemical determination of uric acid, dopamine, and ascorbic acid at single-walled carbon nanohorn modified glassy carbon electrode. , 2009, Biosensors & bioelectronics.

[47]  A. Castellote,et al.  Rapid high-performance liquid chromatographic method for Vitamin C determination in human milk versus an enzymatic method. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[48]  A. Kyaw A simple colorimetric method for ascorbic acid determination in blood plasma. , 1978, Clinica chimica acta; international journal of clinical chemistry.

[49]  P. Kastl,et al.  High-performance liquid chromatographic determination of ascorbic acid in human tears. , 1987, Journal of chromatography.

[50]  A. Ringvold,et al.  Distribution of ascorbate in the anterior bovine eye. , 2000, Investigative ophthalmology & visual science.