Design of phase-modulated broadband refocusing pulses.

Broadband linear-phase refocusing pulses were designed with the Shinnar-Le Roux (SLR) transformation and verified experimentally. The design works in several steps: initially, a linear-phase B polynomial is created with the Parks-McClellan/Remez exchange algorithm. The complementary A polynomial required for the SLR transformation is generated with the Hilbert transformation, yielding the minimum-phase response. The phase response of the A polynomial is altered by zero-flipping, which changes the overall pulse shape while retaining its refocusing profile. Optimal pulses in terms of minimal B(1max) and hence broadest bandwidth were found with non-linear optimisation of the zero-flipping pattern. These pulses are generally phase modulated with a time-symmetric amplitude and anti-symmetric phase modulation. In this work, a whole range of pulses were designed to demonstrate the underlying relationships. Five exemplary pulses were implemented into a PRESS sequence and validated by acquiring images of a water-oil phantom and lactate spectra at TE = 144 ms.

[1]  J. Pauly,et al.  Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm [NMR imaging]. , 1991, IEEE transactions on medical imaging.

[2]  G C McKinnon,et al.  Optimized outer volume suppression for single‐shot fast spin‐echo cardiac imaging , 1998, Journal of magnetic resonance imaging : JMRI.

[3]  P Boesiger,et al.  Pitfalls in lactate measurements at 3T. , 2006, AJNR. American journal of neuroradiology.

[4]  S. Pickup,et al.  Pulses with fixed magnitude and variable phase response profiles , 1995, Magnetic resonance in medicine.

[5]  J. McClellan,et al.  Chebyshev Approximation for Nonrecursive Digital Filters with Linear Phase , 1972 .

[6]  Meir Shinnar Reduced power selective excitation radio frequency pulses , 1994, Magnetic resonance in medicine.

[7]  P. Bottomley Spatial Localization in NMR Spectroscopy in Vivo , 1987, Annals of the New York Academy of Sciences.

[8]  David E. Goldberg,et al.  Genetic Algorithms in Search Optimization and Machine Learning , 1988 .

[9]  M. Popescu,et al.  Efficient design of pulses with trapezoidal magnitude and linear phase response profiles , 1997, Magnetic resonance in medicine.

[10]  J. Kurhanewicz,et al.  Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer , 2000, Magnetic resonance in medicine.

[11]  W.M.M.J. Bovée,et al.  A single-shot localization pulse sequence suited for coils with inhomogeneous RF fields using adiabatic slice-selective RF pulses , 1991 .

[12]  Jens Frahm,et al.  Localized proton spectroscopy using stimulated echoes. , 1987 .

[13]  L. Wald,et al.  Lactate detection at 3T: Compensating J coupling effects with BASING , 1999, Journal of magnetic resonance imaging : JMRI.

[14]  A. J. Shaka,et al.  Water Suppression That Works. Excitation Sculpting Using Arbitrary Wave-Forms and Pulsed-Field Gradients , 1995 .

[15]  A Simple Method for the Construction of 180° Refocusing RF Pulses for Use in Nuclear Magnetic Resonance Imaging , 1993 .

[16]  P. Roux Suites Régulières d'Impulsions Radio-Fréquence en Résonance Magnétique. Application à l'IRM. , 2006 .

[17]  A. Papoulis Signal Analysis , 1977 .

[18]  A. Lent,et al.  Computer-optimized narrowband pulses for multislice imaging , 1987 .

[19]  J J Neil,et al.  Homonuclear J coupling effects in volume localized NMR spectroscopy: Pitfalls and solutions , 1998, Magnetic resonance in medicine.

[20]  L DelaBarre,et al.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR. , 2001, Journal of magnetic resonance.

[21]  P. Boesiger,et al.  Design of broadband RF pulses with polynomial-phase response. , 2007, Journal of magnetic resonance.

[22]  Michael Schär,et al.  Optimized detection of lactate at high fields using inner volume saturation , 2006, Magnetic resonance in medicine.

[23]  P. Boesiger,et al.  Equi-ripple design of quadratic-phase RF pulses. , 2004, Journal of magnetic resonance.