A Novel Calibration-Free Method of Measurement of Oxygen Saturation in Arterial Blood

In present-day pulse oximeters, oxygen saturation in arterial blood (SpO2) is computed by utilizing an empirical relationship extracted from a calibration curve. The calibration curve is obtained by curve-fitting data acquired from volunteers. A novel method of computation of SpO2 that does not require the use of a calibration curve is presented in this paper. Based on a model for the attenuation of light through skin, tissue, bone, and blood, suitable processing steps are identified so that the analytical expression derived for the estimation of SpO2 becomes free of not only patient but sensor-dependent parameters as well. The experimental results presented in this paper establish the efficacy of the proposed method.

[1]  Y. Mendelson Pulse oximetry: theory and applications for noninvasive monitoring. , 1992, Clinical chemistry.

[2]  T. L. Rusch,et al.  Signal processing methods for pulse oximetry , 1996, Comput. Biol. Medicine.

[3]  J. Dudenhausen,et al.  8 Fetal pulse oximetry , 1996 .

[4]  John G. Webster,et al.  Design of Pulse Oximeters , 1997 .

[5]  P.D. Mannheimer,et al.  Wavelength selection for low-saturation pulse oximetry , 1997, IEEE Transactions on Biomedical Engineering.

[6]  J. Sinex Pulse oximetry: principles and limitations. , 1999, The American journal of emergency medicine.

[7]  J. Salyer,et al.  Neonatal and pediatric pulse oximetry. , 2003, Respiratory care.

[8]  Uday Shankar,et al.  Pulse oximetry theory and calibration for low saturations , 2004, IEEE Transactions on Biomedical Engineering.

[9]  Roy D. Wallen,et al.  System Theory and Practical Applications of Biomedical Signals , 2004 .

[10]  Hanli Liu,et al.  Extinction coefficients of hemoglobin for near-infrared spectroscopy of tissue , 2005, IEEE Engineering in Medicine and Biology Magazine.

[11]  J. N. Liu,et al.  Computer analysis system of blood oxygen saturation in an animal hypoxia model , 2006, Medical and Biological Engineering and Computing.

[12]  L. Tarassenko,et al.  Pulse oximetry: Theoretical and experimental models , 2006, Medical and Biological Engineering and Computing.

[13]  B. George,et al.  A Novel Method of Measurement of Oxygen Saturation in Arterial Blood , 2008, 2008 IEEE Instrumentation and Measurement Technology Conference.

[14]  M. Nitzan,et al.  The measurement of oxygen saturation in arterial and venous blood , 2008, IEEE Instrumentation & Measurement Magazine.