Low noise front end ASIC with current mode active cooled termination for the Upgrade of the LHCb Calorimeter

An integrated circuit for the Upgrade of the LHCb Calorimeter front end electronics is presented. The circuit is based on a current mode input stage followed by two fully differential interleaved channels with a switched integrator and a track and hold. The input stage employs a novel electronically cooled input termination scheme to achieve the stringent noise requirements. Compared to previous designs, its novelty relies in the use of two current feedback loops to decrease and control the input impedance of a common base stage. Two prototypes in AMS SiGe BiCMOS 0.35um technology have been designed and tested. Key measurements have been performed. Reflection coefficient is smaller than 0.5% for the full dynamic range, which is 12 bits. Relative linearity error is below 1 %. Output noise is about 1 LSB after aplying correlated double sampling.

[1]  C. Abellán,et al.  Low noise front end ICECAL ASIC for the upgrade of the LHCb calorimeter , 2012 .

[2]  Lluis Garrido,et al.  Noise Analysis of Time Variant Shapers in Frequency Domain , 2011, IEEE Transactions on Nuclear Science.

[3]  N. Dressnandt,et al.  LAPAS: A SiGe Front End Prototype for the Upgraded ATLAS LAr Calorimeter , 2009 .

[4]  E. Jans The LHCb detector , 2009, 0910.1740.

[5]  Fei Yuan,et al.  Low-voltage CMOS current-mode preamplifier: analysis and design , 2006, IEEE Trans. Circuits Syst. I Regul. Pap..

[6]  Wenhua Yang,et al.  A 3-V 340-mW 14-b 75-Msample/s CMOS ADC with 85-dB SFDR at Nyquist input , 2001, IEEE J. Solid State Circuits.

[7]  D. V. Camin,et al.  Stability of a line receiver (0–T) preamplifier, connected to a capacitive detector via a transmission line , 1999 .

[8]  S. Rescia,et al.  A linear low power remote preamplifier for the ATLAS liquid argon EM calorimeter , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[9]  Stephen H. Lewis,et al.  Determination of stability using return ratios in balanced fully differential feedback circuits , 1995 .

[10]  R. L. Chase,et al.  Transmission line connections between detector and front end electronics in liquid argon calorimetry , 1993 .

[11]  H. Kobayashi,et al.  SEMICONDUCTOR RADIATION DETECTORS , 1964 .

[12]  Xavier Vilasis-Cardona,et al.  Study of a Solution with COTS for the LHCb Calorimeter Upgrade , 2012 .

[13]  G. Lutz,et al.  Semiconductor Radiation Detectors , 2007 .