The design and performance characteristics of a multileaf collimator

A multileaf collimator, which has been in routine clinical use for both conventional and conformal radiotherapy for over four years, is described in detail. The collimator replaces the conventional treatment head of a Philips SL series linear accelerator and comprises 80 tungsten leaves and two orthogonal pairs of back-up collimators. Each leaf projects a width of 1 cm in the isocentric plane, allowing shaped photon treatment beams of up to 40 cm square. The performance of the prototype and first production model have been thoroughly tested against the design specifications and the requirements of IEC standards. Radiation attenuation by the collimator components has been measured and substantially exceeds those requirements. The irregular portion of a field (shielded by the leaves only) receives, on average, a dose of less than 2% of the tumour dose. The effect on the penumbra of using leaves which translate linearly and have curved faces has been assessed and found not to degrade the sharpness of the beam fall-off significantly. The reproducibility of the video system used in positioning the leaves has been measured and gave a root mean square deviation of less than 0.3 mm in repeat setting of a 10 cm square field, and an accuracy always within 1 mm. The rationale for clinical use of the device is discussed and its effect on treatment quality control and reliability, is considered.

[1]  B S PROIMOS,et al.  Synchronous field shaping in rotational megavolt therapy. , 1960, Radiology.

[2]  J. G. Trump,et al.  Synchronous field shaping and protection in 2-million-volt rotational therapy. , 1961, Radiology.

[3]  Toshio Ueda APPLICATION OF CONFORMATION RADIOTHERAPY AND ITS TECHNICAL PROBLEMS , 1976 .

[4]  J J Weinkam,et al.  Automatic variation of field size and dose rate in rotation therapy. , 1977, International journal of radiation oncology, biology, physics.

[5]  P. K. Kijewski,et al.  Computer-controlled radiation therapy. , 1977, Radiology.

[6]  J A Brace,et al.  Conformation therapy at the Royal Free Hospital. A progress report on the tracking cobalt project. , 1981, The British journal of radiology.

[7]  H D Suit,et al.  Potential for improving survival rates for the cancer patient by increasing the efficacy of treatment of the primary lesion , 1982, Cancer.

[8]  A. Montelius,et al.  Neutron beam characteristics from 50 MeV protons on beryllium using a continuously variable multi-leaf collimator. , 1983, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  P K Kijewski,et al.  Dose optimization with computer-controlled gantry rotation, collimator motion and dose-rate variation. , 1983, International journal of radiation oncology, biology, physics.

[10]  A B Wolbarst,et al.  Optimization of radiation therapy, III: A method of assessing complication probabilities from dose-volume histograms. , 1987, International journal of radiation oncology, biology, physics.

[11]  Simon Kramer,et al.  The relationship of dose to infield failure for stages A, B and C prostate cancer. An analysis of 1516 patients , 1987 .

[12]  A Brahme,et al.  Design principles and clinical possibilities with a new generation of radiation therapy equipment. A review. , 1987, Acta oncologica.

[13]  K. Nakagawa,et al.  An integrated radiotherapy treatment system and its clinical application. , 1987, Radiation medicine.

[14]  A Brahme,et al.  Shaping of arbitrary dose distributions by dynamic multileaf collimation. , 1988, Physics in medicine and biology.

[15]  S Sakuma,et al.  Computer-assisted rotation and multiple stationary irradiation technique. Newly designed overrunning multi-leaf collimators for conformation radiotherapy. , 1988, European journal of radiology.

[16]  W Schlegel,et al.  Treatment planning for conformation therapy using a multi-leaf collimator. , 1988, Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al].

[17]  Anders Brahme Optimal setting of multileaf collimators in stationary beam radiation therapy. , 1988, Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al].

[18]  S Sakuma,et al.  Computer-assisted conformation radiotherapy with a variable thickness multi-leaf filter. , 1989, International journal of radiation oncology, biology, physics.

[19]  M. J. Day,et al.  The effect of secondary electron spread on the penumbra in high energy photon beam therapy. , 1990, British Journal of Radiology.

[20]  J M Wilkinson,et al.  Tissue standard ratios for irregularly shaped radiotherapy fields. , 1990, The British journal of radiology.

[21]  A S Lichter,et al.  Three-dimensional conformal radiation therapy: a testable hypothesis. , 1991, International journal of radiation oncology, biology, physics.

[22]  W J Lorenz,et al.  Modification of a three-dimensional treatment planning system for the use of multi-leaf collimators in conformation radiotherapy. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[23]  R Mohan,et al.  The biological basis for conformal three-dimensional radiation therapy. , 1991, International journal of radiation oncology, biology, physics.

[24]  J M Wilkinson,et al.  Computer-assisted generation of multi-leaf collimator settings for conformation therapy. , 1992, The British journal of radiology.

[25]  A. Boyer,et al.  Dose distributions of x-ray fields as shaped with multileaf collimators. , 1992, Physics in medicine and biology.

[26]  James M. Galvin,et al.  CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM , 1993 .