A Robust Two-Level Coordinated Static Voltage Security Region for Centrally Integrated Wind Farms

Integration of centralized wind farms may induce cascading tripping incidents, which brings about critical challenges to secure operation of power grid. One of the major risks is the lack of coordinated voltage/reactive power control for multiple wind farms. Therefore, a robust master-slave two-level coordinated static voltage security region (VSR) is proposed in this paper, along with detailed modeling of the network topology and wind farms to achieve coordination among wind farms. The slave VSR on the wind-farm-side is designed to guarantee the operation of each wind unit within a secure range in order to protect wind units from serious over-voltage and low-voltage problems, whereas the master system-wide VSR aims to coordinate centralized wind farms to ensure security both under normal operating conditions and N - 1 contingency conditions. Furthermore, a hierarchically iterative coordination method is introduced to compute the voltage security range of each wind farm through the iteration process. A modified six-bus system with two wind farms, a real system from Northern China, and a large system with 972 wind units are studied, and results verify the effectiveness of the proposed two-level VSR and the hierarchically iterative coordination method.

[1]  I. Erlich,et al.  Enhanced Voltage Drop Control by VSC–HVDC Systems for Improving Wind Farm Fault Ridethrough Capability , 2014, IEEE Transactions on Power Delivery.

[2]  M. Bollen,et al.  Wind power plant collector system design considerations: IEEE PES wind plant collector system design working group , 2009, 2009 IEEE Power & Energy Society General Meeting.

[3]  R D Zimmerman,et al.  MATPOWER: Steady-State Operations, Planning, and Analysis Tools for Power Systems Research and Education , 2011, IEEE Transactions on Power Systems.

[4]  N. Samaan,et al.  Characteristics of wind turbine generators for wind power plants , 2009, 2009 IEEE Power & Energy Society General Meeting.

[5]  E. Vittal,et al.  A Steady-State Voltage Stability Analysis of Power Systems With High Penetrations of Wind , 2010, IEEE Transactions on Power Systems.

[6]  A. Tapia,et al.  Proportional–Integral Regulator-Based Approach to Wind Farm Reactive Power Management for Secondary Voltage Control , 2007, IEEE Transactions on Energy Conversion.

[7]  Hongbin Sun,et al.  A Static Voltage Security Region for Centralized Wind Power Integration—Part I: Concept and Method , 2014 .

[8]  Bin Wang,et al.  A quadratic robust optimization model for automatic voltage control on wind farm side , 2013, 2013 IEEE Power & Energy Society General Meeting.

[9]  J. Niiranen,et al.  Ride-Through Analysis of Doubly Fed Induction Wind-Power Generator Under Unsymmetrical Network Disturbance , 2006, IEEE Transactions on Power Systems.

[10]  D. Santos-Martin,et al.  Providing Ride-Through Capability to a Doubly Fed Induction Generator Under Unbalanced Voltage Dips , 2009, IEEE Transactions on Power Electronics.

[11]  Hongbin Sun,et al.  A Static Voltage Security Region for Centralized Wind Power Integration-Part II: Applications , 2014 .

[12]  Ramon E. Moore Methods and applications of interval analysis , 1979, SIAM studies in applied mathematics.

[13]  Li Wang,et al.  Dynamic Stability Analysis of a DFIG-Based Offshore Wind Farm Connected to a Power Grid Through an HVDC Link , 2011, IEEE Transactions on Power Systems.

[14]  Li Wang,et al.  Comparative Stability Analysis of Offshore Wind and Marine-Current Farms Feeding Into a Power Grid Using HVDC Links and HVAC Line , 2013, IEEE Transactions on Power Delivery.

[15]  A. Pahwa,et al.  Effective Wind Farm Sizing Method for Weak Power Systems Using Critical Modes of Voltage Instability , 2012, IEEE Transactions on Power Systems.

[16]  S. Q. Bu,et al.  Probabilistic Analysis of Small-Signal Rotor Angle/Voltage Stability of Large-Scale AC/DC Power Systems as Affected by Grid-Connected Offshore Wind Generation , 2013, IEEE Transactions on Power Systems.

[17]  D. Thukaram,et al.  Coordination of Reactive Power in Grid-Connected Wind Farms for Voltage Stability Enhancement , 2014, IEEE Transactions on Power Systems.

[18]  D Ramirez,et al.  Low-Voltage Ride-Through Capability for Wind Generators Based on Dynamic Voltage Restorers , 2011, IEEE Transactions on Energy Conversion.

[19]  Lidong Zhang,et al.  Offshore Wind Integration to a Weak Grid by VSC-HVDC Links Using Power-Synchronization Control: A Case Study , 2014, IEEE Transactions on Power Delivery.

[20]  Andrew Keane,et al.  Identification of Critical Wind Farm Locations for Improved Stability and System Planning , 2013, IEEE Transactions on Power Systems.

[21]  S. Santoso,et al.  Augmenting Wind Power Penetration and Grid Voltage Stability Limits Using ESS: Application Design, Sizing, and a Case Study , 2012, IEEE Transactions on Power Systems.