MRI contrast from relaxation along a fictitious field (RAFF)

A new method to measure rotating frame relaxation and to create contrast for MRI is introduced. The technique exploits relaxation along a fictitious field (RAFF) generated by amplitude‐ and frequency‐modulated irradiation in a subadiabatic condition. Here, RAFF is demonstrated using a radiofrequency pulse based on sine and cosine amplitude and frequency modulations of equal amplitudes, which gives rise to a stationary fictitious magnetic field in a doubly rotating frame. According to dipolar relaxation theory, the RAFF relaxation time constant (TRAFF) was found to differ from laboratory frame relaxation times (T1 and T2) and rotating frame relaxation times (T1ρ and T2ρ). This prediction was supported by experimental results obtained from human brain in vivo and three different solutions. Results from relaxation mapping in human brain demonstrated the ability to create MRI contrast based on RAFF. The value of TRAFF was found to be insensitive to the initial orientation of the magnetization vector. In the RAFF method, the useful bandwidth did not decrease as the train length increased. Finally, as compared with an adiabatic pulse train of equal duration, RAFF required less radiofrequency power and therefore can be more readily used for rotating frame relaxation studies in humans. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.

[1]  Michael Garwood,et al.  Relaxation During Adiabatic Radiofrequency Pulses , 2007 .

[2]  D. Grant,et al.  Spin–lattice relaxation in coupled three spin systems of the AIS type , 1975 .

[3]  Arijitt Borthakur,et al.  Sodium and T1ρ MRI for molecular and diagnostic imaging of articular cartilage , 2006, NMR in biomedicine.

[4]  Olli Gröhn,et al.  Exchange‐influenced T2ρ contrast in human brain images measured with adiabatic radio frequency pulses , 2005, Magnetic resonance in medicine.

[5]  M. Billeter,et al.  NMR studies of Brownian tumbling and internal motions in proteins , 2001 .

[6]  Michael Garwood,et al.  T1rho MRI contrast in the human brain: modulation of the longitudinal rotating frame relaxation shutter-speed during an adiabatic RF pulse. , 2006, Journal of magnetic resonance.

[7]  M. E. Rose Elementary Theory of Angular Momentum , 1957 .

[8]  K Ugurbil,et al.  Detunable transverse electromagnetic (TEM) volume coil for high‐field NMR , 2002, Magnetic resonance in medicine.

[9]  M. Garwood,et al.  Simultaneous Compensation for B1 Inhomogeneity and Resonance Offsets by a Multiple-Quantum NMR Sequence Using Adiabatic Pulses , 1995 .

[10]  R. Goebel,et al.  7T vs. 4T: RF power, homogeneity, and signal‐to‐noise comparison in head images , 2001, Magnetic resonance in medicine.

[11]  Michael Garwood,et al.  Quantitative T1ρ and adiabatic Carr–Purcell T2 magnetic resonance imaging of human occipital lobe at 4 T , 2005, Magnetic resonance in medicine.

[12]  Masashi Yamaguchi,et al.  Side Chain Dynamics in Poly(γ-benzyl L-glutamate) as Studied by High-Resolution Solid State 13C Nuclear Magnetic Relaxation in Rotating Frame , 1993 .

[13]  I. Weinberg,et al.  Concentration Dependence of Chemical Exchange and NMR Multiplet Structure in Water‐Ethanol Mixtures , 1955 .

[14]  I. Solomon,et al.  ROTARY SPIN ECHOES , 1959 .

[15]  David T. Pegg,et al.  Uniform sample excitation with surface coils for in vivo spectroscopy by adiabatic rapid half passage , 1986 .

[16]  A. Haase,et al.  Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging , 1990, Magnetic resonance in medicine.

[17]  K. Uğurbil,et al.  Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivo , 2007, Magnetic resonance in medicine.

[18]  Y. Zur,et al.  Is the sech/tanh Adiabatic Pulse Really Adiabatic? , 1998 .

[19]  Seppo Ylä-Herttuala,et al.  Early gene therapy–induced apoptotic response in BT4C gliomas by magnetic resonance relaxation contrast T1 in the rotating frame , 2002, Cancer Gene Therapy.

[20]  Michael Garwood,et al.  Transverse relaxation in the rotating frame induced by chemical exchange. , 2004, Journal of magnetic resonance.

[21]  E. Zuiderweg,et al.  PROTEIN NMR RELAXATION : THEORY, APPLICATIONS AND OUTLOOK , 1998 .

[22]  A. Borthakur,et al.  Compensation for spin‐lock artifacts using an off‐resonance rotary echo in T1ρoff‐weighted imaging , 2007, Magnetic resonance in medicine.

[23]  K. Uğurbil,et al.  Assessment of brain iron and neuronal integrity in patients with Parkinson's disease using novel MRI contrasts , 2007, Movement disorders : official journal of the Movement Disorder Society.

[24]  Gary H Glover,et al.  Rapid MRI method for mapping the longitudinal relaxation time. , 2006, Journal of magnetic resonance.

[25]  D. T. Pegg,et al.  Adiabatic refocusing pulse which compensates for variable of power and off‐resonance effects , 1987, Magnetic resonance in medicine.

[26]  L DelaBarre,et al.  The return of the frequency sweep: designing adiabatic pulses for contemporary NMR. , 2001, Journal of magnetic resonance.

[27]  Asla Pitkänen,et al.  Early Detection of Irreversible Cerebral Ischemia in the Rat Using Dispersion of the Magnetic Resonance Imaging Relaxation Time, T1ρ , 2000, Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism.

[28]  H. Carr,et al.  The Principles of Nuclear Magnetism , 1961 .

[29]  A. Palmer,et al.  On the use of the stochastic Liouville equation in nuclear magnetic resonance: Application to R1ρ relaxation in the presence of exchange , 2003 .

[30]  Arijitt Borthakur,et al.  Artifacts in T1ρ-weighted imaging: Compensation for B1 and B0 field imperfections , 2007 .

[31]  Alejandra Sierra,et al.  Low spin-lock field T1 relaxation in the rotating frame as a sensitive MR imaging marker for gene therapy treatment response in rat glioma. , 2007, Radiology.

[32]  J. Listinsky,et al.  Clinical Magnetic Resonance Imaging and Spectroscopy , 1992 .

[33]  D. Hoult,et al.  Selective population inversion in NMR , 1984, Nature.

[34]  Superadiabaticity in magnetic resonance. , 2008, The Journal of chemical physics.

[35]  C D Kroenke,et al.  Nuclear magnetic resonance methods for quantifying microsecond-to-millisecond motions in biological macromolecules. , 2001, Methods in enzymology.