Longitudinal flow spiral recuperators in building ventilation systems

Abstract Capital expenditure and exploitation costs of ventilation systems with longitudinal counterflow spiral recuperators are minimized taking into consideration the results of measurements and calculations together with the well-known effectiveness–NTU method. It was estimated that ventilation system with longitudinal flow spiral recuperators refunds the capital expenditure within 2 or 3 years. Due to their advantages, spiral recuperators with the longitudinal counter current flow should be widely utilized for ventilation systems in winter and cool recuperation in summer.

[1]  D. T. Reindl,et al.  The Relationship of Optimum Heat Exchanger Allocation and Minimum Entropy Generation Rate for Refrigeration Cycles , 1998 .

[2]  R. M. Wood,et al.  A Method for Automated Heat-Exchanger Network Synthesis Using Block Decomposition and Nonlinear Optimization , 1995 .

[3]  D. Depeyre,et al.  Computerized optimum design and dynamic simulation of heat exchanger networks , 1993 .

[4]  D. Reay,et al.  Comparative merits of heat recovery equipment , 1982 .

[5]  Adrian Bejan,et al.  Thermodynamic optimization of finned crossflow heat exchangers for aircraft environmental control systems , 2001 .

[6]  Claude-Alain Roulet,et al.  Real heat recovery with air handling units , 2001 .

[7]  Adrian Bejan,et al.  Thermodynamic optimization of geometric structure in the counterflow heat exchanger for an environmental control system , 2001 .

[8]  Ramesh K. Shah,et al.  Entropy generation extrema and their relationship with heat exchanger effectiveness: Number of transfer unit behavior for complex flow arrangements , 2004 .

[9]  Adrian Bejan,et al.  Method of entropy generation minimization, or modeling and optimization based on combined heat transfer and thermodynamics , 1996 .

[10]  V. I. Evenko,et al.  Optimization of the energy index of a heat exchanger , 1995 .

[11]  A. Bejan Advanced Engineering Thermodynamics , 1988 .

[12]  George Edward Lockett,et al.  Heat Recovery Systems , 1979 .

[13]  M. L. Warren Fan energy use in variable air volume systems , 1986 .

[14]  D. A. Reay A review of gas-gas heat recovery systems , 1981 .

[15]  Per Lundqvist,et al.  Heat recovery and floating condensing in supermarkets , 2006 .

[16]  M. S Söylemez On the optimum heat exchanger sizing for heat recovery , 2000 .

[17]  Svend Svendsen,et al.  Energy savings in Danish residential building stock , 2006 .

[18]  Juan M. Zamora,et al.  A global MINLP optimization algorithm for the synthesis of heat exchanger networks with no stream splits , 1998 .

[19]  G. T. Polley,et al.  Optimum heat exchanger design : Process design , 1992 .

[20]  Refrigerating ASHRAE handbook. Heating, ventilating, and air-conditioning systems and equipment , 1992 .

[21]  A. Gasparella,et al.  Technical and economical analysis of heat recovery in building ventilation systems , 1998 .