Experimental design and numerical investigation of a photoacoustic sensor for a low-power, continuous-wave, laser-based frequency-domain photoacoustic microscopy

Abstract. We have developed a photoacoustic (PA) sensor using a low-power, continuous- wave laser and a kHz-range microphone. The sensor is simple, flexible, cost-effective, and compatible with commercial optical microscopes. The sensor enables noncontact PA measurements through air, whereas most current existing PA techniques require an acoustic coupling liquid for detection. The PA sensor has three main components: one is the chamber that holds the sample, the second is a resonator column used to amplify the weak PA signals generated within the sample chamber, and the third is a microphone at the end of the resonator column to detect the amplified signals. The chamber size was designed to be 8  mm  ×  3  mm as the thermal diffusion length and viscous-thermal damping of air at room pressure and temperature are 2 and 1 mm, respectively. We numerically and experimentally examined the effect of the resonator column size on the frequency response of the PA sensor. The quality factor decreased significantly when the sample chamber size was reduced from 4  mm  ×  3  mm to 2  mm  ×  3  mm due to thermos-viscous damping of the air. The quality factor decreased by 27%, demonstrating the need for optimal design for the sample chamber and resonator column size. The system exhibited noise equivalent molecular sensitivity (NEM) per unit bandwidth (NEM  /    √  Δf) of ∼19,966  Hz  −  1/2 or 33  ×  10  −  21  mol or 33 zeptomol, which is an improvement of 2.2 times compared to the previous system design. This PA sensor has the potential for noncontact high-resolution PA imaging of materials without the need for coupling fluids.

[1]  Matthias Abt Photoacoustics And Photoacoustic Spectroscopy , 2016 .

[2]  Christoph Haisch,et al.  Photoacoustic spectroscopy for analytical measurements , 2011 .

[3]  Mukund Seshadri,et al.  Non-invasive, Multimodal Functional Imaging of the Intestine with Frozen Micellar Naphthalocyanines , 2014, Nature nanotechnology.

[4]  A. Bell On the production and reproduction of sound by light , 1880, American Journal of Science.

[5]  S. Arridge,et al.  Quantitative spectroscopic photoacoustic imaging: a review. , 2012, Journal of biomedical optics.

[6]  Vincenzo Spagnolo,et al.  Photoacoustic Techniques for Trace Gas Sensing Based on Semiconductor Laser Sources , 2009, Sensors.

[7]  Junjie Yao,et al.  Photoacoustic microscopy , 2013, Laser & photonics reviews.

[8]  Andreas Mandelis,et al.  Frequency-domain photothermoacoustics: Alternative imaging modality of biological tissues , 2009 .

[9]  Michael C. Kolios,et al.  Photoacoustic F-Mode imaging for scale specific contrast in biological systems , 2019, Communications Physics.

[10]  M. Wolff,et al.  Modeling and Numerical Investigation of Photoacoustic Resonators , 2008 .

[11]  Chulhong Kim,et al.  Acoustic resolution photoacoustic microscopy , 2014, Biomedical Engineering Letters.

[12]  L. Kreuzer,et al.  Ultralow Gas Concentration Infrared Absorption Spectroscopy , 1971 .

[13]  Michael Lopresto Experimenting with end-correction and the speed of sound , 2011 .

[14]  F. Perennes,et al.  Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[15]  Roderick R. Kunz,et al.  High-sensitivity detection of trace gases using dynamic photoacoustic spectroscopy , 2013 .

[16]  Mehdi Shadaram,et al.  Probe beam deflection technique as acoustic emission directionality sensor with photoacoustic emission source. , 2014, Applied optics.

[17]  J. Atwood,et al.  The laser illuminated absorptivity spectrophone: a method for measurement of weak absorptivity in gases at laser wavelengths. , 1968, Applied optics.

[18]  Jan Laufer,et al.  Backward-mode multiwavelength photoacoustic scanner using a planar Fabry-Perot polymer film ultrasound sensor for high-resolution three-dimensional imaging of biological tissues. , 2008, Applied optics.

[19]  M. P. Kothiyal,et al.  Simple technique for obtaining photoacoustic spectra corrected for the spectral variation of the source in single scan. , 2007, The Review of scientific instruments.

[20]  Vilasrao J. Kadam,et al.  Photoacoustic Spectroscopy and Its Applications – A Tutorial Review , 2010 .

[21]  Vasan Venugopalan,et al.  Optoacoustic imaging based on the interferometric measurement of surface displacement. , 2007, Journal of biomedical optics.

[22]  Vasan Venugopalan,et al.  Optoacoustic tomography using time-resolved interferometric detection of surface displacement. , 2003, Journal of biomedical optics.

[23]  Liren Zhu,et al.  Multi-view optical resolution photoacoustic microscopy. , 2014, Optica.

[24]  C. R. Philbrick,et al.  1 . 1 REMOTE SENSING OF CHEMICAL SPECIES IN THE ATMOSPHERE , 2009 .

[25]  Patrick J. La Rivière,et al.  Comparison of intensity-modulated continuous-wave lasers with a chirped modulation frequency to pulsed lasers for photoacoustic imaging applications , 2010, Biomedical optics express.

[26]  Lihong V. Wang,et al.  Photoacoustic imaging in biomedicine , 2006 .

[27]  A. Kinney,et al.  Applications of Photoacoustic Spectroscopy , 1982 .

[28]  Eric M. Strohm,et al.  High frequency label-free photoacoustic microscopy of single cells☆ , 2013, Photoacoustics.

[29]  A. Rosencwaig,et al.  Photoacoustic spectroscopy. , 1980, Annual review of biophysics and bioengineering.

[30]  Michael C. Kolios,et al.  Low-power noncontact photoacoustic microscope for bioimaging applications , 2017, Journal of biomedical optics.

[31]  Tianheng Wang,et al.  A low-cost photoacoustic microscopy system with a laser diode excitation. , 2014, Biomedical optics express.

[32]  M. Wolff,et al.  Finite element calculation of photoacoustic signals. , 2007, Applied optics.

[33]  Michael J. Moore,et al.  Single Cell Photoacoustic Microscopy: A Review , 2016, IEEE Journal of Selected Topics in Quantum Electronics.

[34]  Chiye Li,et al.  Label-free photoacoustic nanoscopy , 2014, Journal of biomedical optics.

[35]  G. D. den Heeten,et al.  Feasibility of noncontact piezoelectric detection of photoacoustic signals in tissue-mimicking phantoms. , 2010, Journal of biomedical optics.

[36]  Byeong Ha Lee,et al.  Noncontact photoacoustic tomography of in vivo chicken chorioallantoic membrane based on all-fiber heterodyne interferometry , 2015, Journal of biomedical optics.

[37]  Bernhard Jakoby,et al.  Non-contact photoacoustic imaging using a fiber based interferometer with optical amplification. , 2013, Biomedical optics express.

[38]  Takao Kobayashi,et al.  Techniques for laser remote sensing of the environment , 1987 .

[39]  A. D’Alessandro,et al.  Red blood cell proteomics update: is there more to discover? , 2017, Blood transfusion = Trasfusione del sangue.

[40]  Benli Yu,et al.  Recent Progress on Infrared Photoacoustic Spectroscopy Techniques , 2011 .

[41]  Michael C. Kolios,et al.  Insights into photoacoustic speckle and applications in tumor characterization , 2019, Photoacoustics.

[42]  Walter J. Riker A Review of J , 2010 .

[43]  Lihong V. Wang,et al.  Photoacoustic imaging of biological tissue with intensity-modulated continuous-wave laser. , 2008, Journal of biomedical optics.

[44]  Allan Rosencwaig Photoacoustic Spectroscopy of Solids , 1977 .

[45]  Frank Kühnemann,et al.  Transportable, highly sensitive photoacoustic spectrometer based on a continuous-wave dualcavity optical parametric oscillator. , 2003, Optics express.

[46]  P. Beard Biomedical photoacoustic imaging , 2011, Interface Focus.

[47]  Lihong V. Wang,et al.  Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging , 2006, Nature Biotechnology.

[48]  Ruikang K. Wang,et al.  Noncontact photoacoustic imaging achieved by using a low-coherence interferometer as the acoustic detector. , 2011, Optics letters.

[49]  N D Kenyon,et al.  Air Pollution: Sensitive Detection of Ten Pollutant Gases by Carbon Monoxide and Carbon Dioxide Lasers , 1972, Science.

[50]  Lihong V. Wang,et al.  High-speed label-free functional photoacoustic microscopy of mouse brain in action , 2015, Nature Methods.

[51]  Jami L. Johnson,et al.  Gas-coupled laser acoustic detection as a non-contact line detector for photoacoustic and ultrasound imaging , 2016 .