Quantitative analysis of deuterium in zircaloy using double-pulse laser-induced breakdown spectrometry (LIBS) and helium gas plasma without a sample chamber.

A crucial safety measure to be strictly observed in the operation of heavy-water nuclear power plants is the mandatory regular inspection of the concentration of deuterium penetrated into the zircaloy fuel vessels. The existing standard method requires a tedious, destructive, and costly sample preparation process involving the removal of the remaining fuel in the vessel and melting away part of the zircaloy pipe. An alternative method of orthogonal dual-pulse laser-induced breakdown spectrometry (LIBS) is proposed by employing flowing atmospheric helium gas without the use of a sample chamber. The special setup of ps and ns laser systems, operated for the separate ablation of the sample target and the generation of helium gas plasma, respectively, with properly controlled relative timing, has succeeded in producing the desired sharp D I 656.10 nm emission line with effective suppression of the interfering H I 656.28 nm emission by operating the ps ablation laser at very low output energy of 26 mJ and 1 μs ahead of the helium plasma generation. Under this optimal experimental condition, a linear calibration line is attained with practically zero intercept and a 20 μg/g detection limit for D analysis of zircaloy sample while creating a crater only 10 μm in diameter. Therefore, this method promises its potential application for the practical, in situ, and virtually nondestructive quantitative microarea analysis of D, thereby supporting the more-efficient operation and maintenance of heavy-water nuclear power plants. Furthermore, it will also meet the anticipated needs of future nuclear fusion power plants, as well as other important fields of application in the foreseeable future.

[1]  C. Sánchez-Aké,et al.  Emission enhancement using two orthogonal targets in double pulse laser-induced breakdown spectroscopy , 2009 .

[2]  G. Cristoforetti,et al.  Three-dimensional analysis of laser induced plasmas in single and double pulse configuration , 2004 .

[3]  Reinhard Noll,et al.  Laser-induced breakdown spectroscopy of steel samples using multiple Q-switch Nd:YAG laser pulses , 1995 .

[4]  V. Kiris,et al.  Comparison of two laser-induced breakdown spectroscopy techniques for total carbon measurement in soils , 2009 .

[5]  V. Lazic,et al.  A comparison of single and double pulse laser-induced breakdown spectroscopy of aluminum samples , 2002 .

[6]  J. Freidberg,et al.  Fusion–fission hybrids revisited , 2009 .

[7]  A. Miziolek,et al.  Double-pulse standoff laser-induced breakdown spectroscopy for versatile hazardous materials detection , 2007 .

[8]  M. Sabsabi,et al.  Enhanced laser-induced breakdown spectroscopy using the combination of fourth-harmonic and fundamental Nd:YAG laser pulses , 2002 .

[9]  L. J. Radziemski,et al.  Laser-induced breakdown spectroscopy: Time-integrated applications , 1981 .

[10]  D. H. Dieke Session 15. Intensities and Transition Probabilities , 1962 .

[11]  Taesam Kim,et al.  Laser-Induced Breakdown Spectroscopy , 2012 .

[12]  J. Lacour,et al.  Quantification of the intensity enhancements for the double-pulse laser-induced breakdown spectroscopy in the orthogonal beam geometry , 2005 .

[13]  S. Michael Angel,et al.  Effect of Pulse Delay Time on a Pre-Ablation Dual-Pulse LIBS Plasma , 2001 .

[14]  Jagdish P. Singh,et al.  Laser-induced breakdown spectroscopy , 2007 .

[15]  Dimitra N. Stratis,et al.  LIBS using dual- and ultra-short laser pulses , 2001, Fresenius' journal of analytical chemistry.

[16]  S. N. Kosolobov,et al.  Long term operation of high quantum efficiency GaAs(Cs,O) photocathodes using multiple recleaning by atomic hydrogen , 2009 .

[17]  S. Angel,et al.  Dual-Pulse LIBS Using a Pre-Ablation Spark for Enhanced Ablation and Emission , 2000 .

[18]  S. Dou,et al.  A sign of field-induced first order magnetic state transition and giant reversible magnetocaloric effect in cobalt hydroxide nanosheets , 2010 .

[19]  Rinda Hedwig,et al.  Quantitative analysis of deuterium using laser-induced plasma at low pressure of helium. , 2006, Analytical chemistry.

[20]  G. Cristoforetti,et al.  Influence of ambient gas pressure on laser-induced breakdown spectroscopy technique in the parallel double-pulse configuration , 2004 .

[21]  Stefano Legnaioli,et al.  Spectroscopic and shadowgraphic analysis of laser induced plasmas in the orthogonal double pulse pre-ablation configuration , 2006 .

[22]  K. Niemax,et al.  Basic investigations for laser microanalysis: III. Application of different buffer gases for laser-produced sample plumes , 1992 .

[23]  Maki Suemitsu,et al.  Effects of the Hole Tunneling Barrier Width on the Electrical Characteristic in Silicon Quantum Dots Light-Emitting Diodes , 2011 .

[24]  Kiichiro Kagawa,et al.  Hydrogen and Deuterium Analysis Using Laser‐Induced Plasma Spectroscopy , 2006 .

[25]  S. Michael Angel,et al.  Enhancement of Aluminum, Titanium, and Iron in Glass Using Pre-Ablation Spark Dual-Pulse LIBS , 2000 .