Feasibility of real-time magnetic resonance imaging-guided electrophysiology studies in humans.

AIMS Magnetic resonance imaging (MRI) in the context of electrophysiology (EP) studies facilitates visualization of complex three-dimensional anatomy and the underlying arrhythmogenic substrate, real-time passive visualization of catheters, atrial and ventricular function and complications, as well as lesion visualization during the ablation without radiation. In the following we report on our first experience of a real-time MRI-guided EP study demonstrating current possibilities and drawbacks. METHODS AND RESULTS Five consecutive patients (one male, four female; mean age 66 ± 11 years) with symptomatic arrhythmias, three patients with highly symptomatic typical atrial flutter, presented to our hospital for isthmus ablation, one patient for an EP study and one for slow pathway ablation in atrioventricular node re-entry tachychardia. The four ablations were performed successfully in a conventional EP laboratory and complete bidirectional isthmus block was confirmed in three patients with atrial flutter. After the procedure in the EP laboratory all five patients were transferred to a 1.5 T whole-body MRI scanner (Intera) for a diagnostic EP procedure. Two MRI compatible steerable diagnostic/ablation catheters (Vision) were inserted via the femoral sheaths and manipulated by an experienced electrophysiologist using a commercially available interactive real-time steady-state free precession sequence (repetition time = 3 ms, echo time = 1 ms, flip angle = 35°, slice thickness = 10 mm, frame rate = 8/s). All catheters could be placed successfully in the right atrium and ventricle, confirmed by intracardiac electrograms, using passive catheter tracking. Furthermore, simple programmed stimulation maneuvers were performed. During and after the procedure, no adverse effects were observed in any patients. CONCLUSION To our knowledge, this is the first series of patients with real-time MRI-guided placement of multiple catheters with subsequent performance of stimulation maneuvers. Besides the mentioned benefits, this technology still encounters several limitations, which have to be solved before application in a routine clinical setting. Challenges arise from delineation of precise surface electrocardiogram recordings in the MRI setting along with intracardiac electrograms, easier handling and visualization of catheters, facilitation of immediate defibrillation in the MRI setting and implementation of an active catheter tracking system.

[1]  G. Hindricks The Multicentre European Radiofrequency Survey (MERFS): complications of radiofrequency catheter ablation of arrhythmias. The Multicentre European Radiofrequency Survey (MERFS) investigators of the Working Group on Arrhythmias of the European Society of Cardiology. , 1993, European heart journal.

[2]  M. Scheinman NASPE Survey on Catheter Ablation , 1995, Pacing and clinical electrophysiology : PACE.

[3]  ACC/AHA Task Force Report. Guidelines for Clinical Intracardiac Electrophysiological and Catheter Ablation Procedures. A report of the American College of Cardiology/American Heart Association task force on practice guidelines (Committee on Clinical Intracardiac Electrophysiologic and Catheter Ablat , 1995, Journal of cardiovascular electrophysiology.

[4]  Richard P. Lewis,et al.  Guidelines for clinical intracardiac electrophysiological and catheter ablation procedures. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee on Clinical Intracardiac Electrophysiologic and Catheter Ablation Procedures), developed , 1995, Journal of the American College of Cardiology.

[5]  Richard P. Lewis,et al.  Guidelines for Clinical Intracardiac Electrophysiological and Catheter Ablation Procedures. A report of the American College of Cardiology/American Heart Association Task Force on practice guidelines. (Committee on Clinical Intracardiac Electrophysiologic and Catheter Ablation Procedures). Developed , 1995, Circulation.

[6]  Ganz Li,et al.  Catheter mapping and ablation of ventricular tachycardia. , 1996 .

[7]  W. Stevenson,et al.  Catheter mapping and ablation of ventricular tachycardia , 1996, Coronary artery disease.

[8]  D. Shah,et al.  Radiofrequency Catheter Ablation of Common Atrial Flutter in 200 Patients , 1996, Journal of cardiovascular electrophysiology.

[9]  Shih-AnnChen,et al.  Is 8-mm More Effective Than 4-mm Tip Electrode Catheter for Ablation of Typical Atrial Flutter? , 1999 .

[10]  Ergin Atalar,et al.  Multifunctional interventional devices for MRI: A combined electrophysiology/MRI catheter , 2002, Magnetic resonance in medicine.

[11]  J M Peeters,et al.  Development and testing of passive tracking markers for different field strengths and tracking speeds , 2006, Physics in medicine and biology.

[12]  Hiroshi Ashikaga,et al.  Feasibility of Real-Time Magnetic Resonance Imaging for Catheter Guidance in Electrophysiology Studies , 2008, Circulation.

[13]  Christopher Piorkowski,et al.  Color-coded three-dimensional entrainment mapping for analysis and treatment of atrial macroreentrant tachycardia. , 2009, Heart rhythm.

[14]  Daniel Steven,et al.  Interactive real-time mapping and catheter ablation of the cavotricuspid isthmus guided by magnetic resonance imaging in a porcine model , 2009, European heart journal.

[15]  E. Kholmovski,et al.  Evaluation of the left atrial substrate in patients with lone atrial fibrillation using delayed-enhanced MRI: implications for disease progression and response to catheter ablation. , 2010, Heart rhythm.

[16]  C. McGann,et al.  MRI of the left atrium: predicting clinical outcomes in patients with atrial fibrillation , 2011, Expert review of cardiovascular therapy.

[17]  W. Saliba,et al.  Catheter ablation for atrial fibrillation. , 2011, The New England journal of medicine.

[18]  G. Hindricks,et al.  Electrophysiology study guided by real-time magnetic resonance imaging. , 2012, European heart journal.

[19]  C. Blomström-Lundqvist,et al.  Current practice of ventricular tachycardia ablation in patients with implantable cardioverter-defibrillators. , 2012, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[20]  K. Kuck,et al.  Correlation between substrate location and ablation strategy in patients with ventricular tachycardia late after myocardial infarction. , 2012, Heart rhythm.