GMR biosensor arrays: a system perspective.

Giant magnetoresistive biosensors are becoming more prevalent for sensitive, quantifiable biomolecular detection. However, in order for magnetic biosensing to become competitive with current optical protein microarray technology, there is a need to increase the number of sensors while maintaining the high sensitivity and fast readout time characteristic of smaller arrays (1-8 sensors). In this paper, we present a circuit architecture scalable for larger sensor arrays (64 individually addressable sensors) while maintaining a high readout rate (scanning the entire array in less than 4s). The system utilizes both time domain multiplexing and frequency domain multiplexing in order to achieve this scan rate. For the implementation, we propose a new circuit architecture that does not use a classical Wheatstone bridge to measure the small change in resistance of the sensor. Instead, an architecture designed around a transimpedance amplifier is employed. A detailed analysis of this architecture including the noise, distortion, and potential sources of errors is presented, followed by a global optimization strategy for the entire system comprising the magnetic tags, sensors, and interface electronics. To demonstrate the sensitivity, quantifiable detection of two blindly spiked samples of unknown concentrations has been performed at concentrations below the limit of detection for the enzyme-linked immunosorbent assay. Lastly, the multiplexing capability and reproducibility of the system was demonstrated by simultaneously monitoring sensors functionalized with three unique proteins at different concentrations in real-time.

[1]  W. Dittmer,et al.  Sensitive and rapid immunoassay for parathyroid hormone using magnetic particle labels and magnetic actuation. , 2008, Journal of immunological methods.

[2]  Hugo Ferreira,et al.  Biodetection using magnetically labeled biomolecules and arrays of spin valve sensors (invited) , 2003 .

[3]  B Murmann,et al.  GMR biosensor arrays: correction techniques for reproducibility and enhanced sensitivity. , 2010, Biosensors & bioelectronics.

[4]  R. Engelbrecht,et al.  DIGEST of TECHNICAL PAPERS , 1959 .

[5]  R. Colton,et al.  The BARC biosensor applied to the detection of biological warfare agents. , 2000, Biosensors & bioelectronics.

[6]  Y. J. Chen,et al.  GMR materials for low field applications , 1993 .

[7]  B. M. de Boer,et al.  An integrated and sensitive detection platform for magneto-resistive biosensors. , 2007, Biosensors & bioelectronics.

[8]  Boris Murmann,et al.  Matrix-insensitive protein assays push the limits of biosensors in medicine , 2009, Nature Medicine.

[9]  Marc D Porter,et al.  Giant magenetoresistive sensors. 2. Detection of biorecognition events at self-referencing and magnetically tagged arrays. , 2008, Analytical chemistry.

[10]  L. Whitman,et al.  Magnetic labeling, detection, and system integration. , 2008, Biosensors & bioelectronics.

[11]  Gil U. Lee,et al.  A biosensor based on magnetoresistance technology. , 1998, Biosensors & bioelectronics.

[12]  L. Sousa,et al.  Femtomolar limit of detection with a magnetoresistive biochip. , 2009, Biosensors & bioelectronics.

[13]  S.X. Wang,et al.  Analytical and micromagnetic modeling for detection of a single magnetic microbead or nanobead by spin valve sensors , 2003, Digest of INTERMAG 2003. International Magnetics Conference (Cat. No.03CH37401).

[14]  Nader Pourmand,et al.  Giant magnetoresistive biochip for DNA detection and HPV genotyping. , 2008, Biosensors & bioelectronics.

[15]  James D. Meindl,et al.  Solid-State Circuits Conference , 1969 .

[16]  Mwj Menno Prins,et al.  Rapid DNA multi-analyte immunoassay on a magneto-resistance biosensor. , 2009, Biosensors & bioelectronics.

[17]  Paul E. Sheehan,et al.  Design and Performance of GMR Sensors for the Detection of Magnetic Microbeads in Biosensors , 2003 .

[18]  Alfred Puehler,et al.  Magnetoresistive Sensors and Magnetic Nanoparticles for Biotechnology , 2005 .