Evaluation of a Second-Generation Ultra-Fast Energy-Resolved ASIC for Photon-Counting Spectral CT

A second-generation ultra-fast energy-resolved application specific integrated circuit (ASIC) has been developed for photon-counting spectral computed tomography (CT). The energy resolution, threshold dispersion and gain of the ASIC were characterized with synchrotron radiation at Diamond Light Source. The standard deviation of threshold offsets at zero keV is 0.89 keV. An RMS energy resolution of 1.09 keV has been demonstrated for 15 keV photon energy at a count rate of 40 kcps, and it deteriorates at a rate of 0.29 keV/Mcps with the increase of output cout rate. The count rate performance of the ASIC has also been evaluated with 120 kV polychromatic x-rays produced by a tungsten anode tube and the results are presented.

[1]  W. Shockley Currents to Conductors Induced by a Moving Point Charge , 1938 .

[2]  S. Ramo Currents Induced by Electron Motion , 1939, Proceedings of the IRE.

[3]  G. De Geronimo,et al.  A CMOS baseline holder (BLH) for readout ASICs , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[4]  P. Shikhaliev Energy-resolved computed tomography: first experimental results , 2008, Physics in medicine and biology.

[5]  J. Schlomka,et al.  Experimental feasibility of multi-energy photon-counting K-edge imaging in pre-clinical computed tomography , 2008, Physics in medicine and biology.

[6]  J. Sempau,et al.  PENELOPE-2006: A Code System for Monte Carlo Simulation of Electron and Photon Transport , 2009 .

[7]  Kawal Sawhney,et al.  A Test Beamline on Diamond Light Source , 2010 .

[8]  M. Danielsson,et al.  Photon-counting spectral computed tomography using silicon strip detectors: a feasibility study , 2010, Physics in medicine and biology.

[9]  Cheng Xu,et al.  Design considerations to overcome cross talk in a photon counting silicon strip detector for computed tomography , 2010 .

[10]  Erik Fredenberg,et al.  Energy resolution of a photon-counting silicon strip detector , 2010, 2101.07789.

[11]  Adam S Wang,et al.  Pulse pileup statistics for energy discriminating photon counting x-ray detectors. , 2011, Medical physics.

[12]  Katsuyuki Taguchi,et al.  Material separation in x-ray CT with energy resolved photon-counting detectors , 2011, Medical Imaging.

[13]  Cheng Xu,et al.  A High-Rate Energy-Resolving Photon-Counting ASIC for Spectral Computed Tomography , 2012, IEEE Transactions on Nuclear Science.

[14]  C. Svensson,et al.  Preliminary evaluation of a silicon strip detector for photon-counting spectral CT , 2012 .