Reproducibility of lung tumor position and reduction of lung mass within the planning target volume using active breathing control (ABC).

PURPOSE The active breathing control (ABC) device allows for temporary immobilization of respiratory motion by implementing a breath hold at a predefined relative lung volume and air flow direction. The purpose of this study was to quantitatively evaluate the ability of the ABC device to immobilize peripheral lung tumors at a reproducible position, increase total lung volume, and thereby reduce lung mass within the planning target volume (PTV). MATERIALS AND METHODS Ten patients with peripheral non-small-cell lung cancer tumors undergoing radiotherapy had CT scans of their thorax with and without ABC inspiration breath hold during the first 5 days of treatment. Total lung volumes were determined from the CT data sets. Each peripheral lung tumor was contoured by one physician on all CT scans to generate gross tumor volumes (GTVs). The lung density and mass contained within a 1.5-cm PTV margin around each peripheral tumor was calculated using CT numbers. Using the center of the GTV from the Day 1 ABC scan as the reference, the displacement of subsequent GTV centers on Days 2 to 5 for each patient with ABC applied was calculated in three dimensions. RESULTS With the use of ABC inspiration breath hold, total lung volumes increased by an average of 42%. This resulted in an average decrease in lung mass of 18% within a standard 1.5-cm PTV margin around the GTV. The average (+/- standard deviation) displacement of GTV centers with ABC breath hold applied was 0.3 mm (+/- 1.8 mm), 1.2 mm (+/- 2.3 mm), and 1.1 mm (+/- 3.5 mm) in the lateral direction, anterior-posterior direction, and superior-inferior direction, respectively. CONCLUSIONS Results from this study indicate that there remains some inter-breath hold variability in peripheral lung tumor position with the use of ABC inspiration breath hold, which prevents significant PTV margin reduction. However, lung volumes can significantly increase, thereby decreasing the mass of lung within a standard PTV.

[1]  Lawrence B Marks,et al.  Dosimetric predictors of radiation-induced lung injury. , 2002, International journal of radiation oncology, biology, physics.

[2]  R K Ten Haken,et al.  The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[3]  J Hanson,et al.  Dosimetric evaluation of lung tumor immobilization using breath hold at deep inspiration. , 2001, International journal of radiation oncology, biology, physics.

[4]  Y. Ung,et al.  Deep inspiration breath hold to reduce irradiated heart volume in breast cancer patients , 2001 .

[5]  H. Shirato,et al.  Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor. , 2000, International journal of radiation oncology, biology, physics.

[6]  R Mackie,et al.  A new approach to dose escalation in non-small-cell lung cancer. , 2001, International journal of radiation oncology, biology, physics.

[7]  Masahiro Endo,et al.  Predictive value of dose-volume histogram parameters for predicting radiation pneumonitis after concurrent chemoradiation for lung cancer. , 2003, International journal of radiation oncology, biology, physics.

[8]  J A Purdy,et al.  Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC) , 1999, International journal of radiation oncology, biology, physics.

[9]  D A Jaffray,et al.  Active breathing control (ABC) for Hodgkin's disease: reduction in normal tissue irradiation with deep inspiration and implications for treatment. , 2000, International journal of radiation oncology, biology, physics.

[10]  B. Murray,et al.  Held-breath self-gating technique for radiotherapy of non-small-cell lung cancer: a feasibility study. , 2001, International journal of radiation oncology, biology, physics.

[11]  R K Ten Haken,et al.  Dose escalation in non-small-cell lung cancer using three-dimensional conformal radiation therapy: update of a phase I trial. , 2001, Journal of clinical oncology : official journal of the American Society of Clinical Oncology.

[12]  C. Ling,et al.  Final report of the 70.2-Gy and 75.6-Gy dose levels of a phase I dose escalation study using three-dimensional conformal radiotherapy in the treatment of inoperable non-small cell lung cancer. , 2000, Cancer journal.

[13]  Michael B Sharpe,et al.  Significant reductions in heart and lung doses using deep inspiration breath hold with active breathing control and intensity-modulated radiation therapy for patients treated with locoregional breast irradiation. , 2003, International journal of radiation oncology, biology, physics.

[14]  J. Wong,et al.  The use of active breathing control (ABC) to reduce margin for breathing motion. , 1999, International journal of radiation oncology, biology, physics.

[15]  W. Stanford,et al.  Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomography. , 1990, International journal of radiation oncology, biology, physics.

[16]  W. Curran,et al.  Final Results of Phase III Trial in Regionally Advanced Unresectable Non-Small Cell Lung Cancer : Radiation Therapy Oncology Group, Eastern Cooperative Oncology Group, and Southwest Oncology Group , 2000 .

[17]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[18]  C C Ling,et al.  The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. , 2000, International journal of radiation oncology, biology, physics.

[19]  R. Arriagada,et al.  Radiotherapy alone versus combined chemotherapy and radiotherapy in unresectable non-small cell lung carcinoma. , 1994, Lung cancer.

[20]  J. Herndon,et al.  Improved survival in stage III non-small-cell lung cancer: seven-year follow-up of cancer and leukemia group B (CALGB) 8433 trial. , 1996, Journal of the National Cancer Institute.

[21]  S Minohara,et al.  Respiratory gated irradiation system for heavy-ion radiotherapy. , 2000, International journal of radiation oncology, biology, physics.