Use of electrosurgery and lasers in the presence of dental implants.

Use of electrosurgery or laser surgery in the presence of metallic implants has been implicated in generating heat-induced injury to peri-implant bone, with the subsequent loss of osseointegration. Studies involving lasers offer conflicting results, while in the case of the electrosurg, little research has been published supporting or refuting these claims. This study measured local heat effects created by use of a unipolar electrosurgical unit, a bipolar electrosurgical unit, and a neodymium:yttrium-aluminum-garnet (Nd:YAG) laser. Absolute temperature increase was measured during an in vitro uncovering surgical procedure performed with each unit. Analysis of variance for repeated measures was performed. Second, absolute temperature increase for each unit was compared with a theoretical clinical limit of a 10 degrees C increase. The findings suggest that use of the unipolar electrosurgical unit should be avoided, while judicious use of both the bipolar unit or the laser unit should produce temperature profiles well within clinical limits.

[1]  P. Lamey,et al.  Infrared thermographic analysis of temperature rise on implant surfaces: a pilot study on abutment preparation. , 1998, Practical periodontics and aesthetic dentistry : PPAD.

[2]  A. Glaros,et al.  Change in temperature of subjacent bone during soft tissue laser ablation. , 1998, Journal of periodontology.

[3]  N Bichacho,et al.  Achieving optimal gingival esthetics around restored natural teeth and implants. Rationale, concepts, and techniques. , 1998, Dental clinics of North America.

[4]  L. Malis Electrosurgery. Technical note. , 1996, Journal of neurosurgery.

[5]  U. Brägger,et al.  Heat generated during preparation of titanium implants of the ITI Dental Implant System: an in vitro study. , 1995, Clinical Oral Implants Research.

[6]  W. Parker,et al.  CO2 lasers and temperature changes of titanium implants. , 1995, Journal of periodontology.

[7]  K. Hargreaves,et al.  Heat generation in hydroxyapatite-coated implants as a result of CO2 laser application. , 1995, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[8]  B. Laufer,et al.  An investigation on heat transfer to the implant-bone interface due to abutment preparation with high-speed cutting instruments. , 1995, The International Journal of Oral and Maxillofacial Implants.

[9]  K. Fastenmeier,,et al.  [High-frequency dental surgery near metal reconstructions]. , 1994, Schweizer Monatsschrift fur Zahnmedizin = Revue mensuelle suisse d'odonto-stomatologie = Rivista mensile svizzera di odontologia e stomatologia.

[10]  C. Ganz Evaluation of the safety of the carbon dioxide laser used in conjunction with root form implants: a pilot study. , 1994, The Journal of prosthetic dentistry.

[11]  A. Ingber,et al.  Esthetic high-strength implant abutments. Part II. , 1993, Journal of esthetic dentistry.

[12]  A. Ingber,et al.  Esthetic high-strength implant abutments. Part I. , 1993, Journal of esthetic dentistry.

[13]  H. Visser,et al.  [HF surgery vs. laser surgery. Experimental study of use in periodontology]. , 1991, ZWR.

[14]  A. Desiate,et al.  Temperature change in the pulp chamber during complete crown preparation. , 1991, The Journal of prosthetic dentistry.

[15]  R Mausberg,et al.  [Comparative investigations of new dental electrosurgical instruments]. , 1990, ZWR.

[16]  T Albrektsson,et al.  Temperature threshold levels for heat-induced bone tissue injury: a vital-microscopic study in the rabbit. , 1983, The Journal of prosthetic dentistry.

[17]  R. Reinhardt,et al.  Effects of electrosurgery on dog pulps under cervical metallic restorations. , 1982, Oral surgery, oral medicine, and oral pathology.

[18]  G. Roby Electrosurgical currents and their effects. , 1982, Dental Clinics of North America.

[19]  Goldstein Aa Radiosurgery in dentistry , 1978 .