Phase Unwrapping in Spectral X-Ray Differential Phase-Contrast Imaging With an Energy-Resolving Photon-Counting Pixel Detector

Grating-based differential phase-contrast imaging has proven to be feasible with conventional X-ray sources. The polychromatic spectrum generally limits the performance of the interferometer but benefit can be gained with an energy-sensitive detector. In the presented work, we employ the energy-discrimination capability to correct for phase-wrapping artefacts. We propose to use the phase shifts, which are measured in distinct energy bins, to estimate the optimal phase shift in the sense of maximum likelihood. We demonstrate that our method is able to correct for phase-wrapping artefacts, to improve the contrast-to-noise ratio and to reduce beam hardening due to the modelled energy dependency. The method is evaluated on experimental data which are measured with a laboratory Talbot-Lau interferometer equipped with a conventional polychromatic X-ray source and an energy-sensitive photon-counting pixel detector. Our work shows, that spectral imaging is an important step to move differential phase-contrast imaging closer to pre-clinical and clinical applications, where phase wrapping is particularly problematic.

[1]  Paola Coan,et al.  X-ray phase-contrast imaging: from pre-clinical applications towards clinics , 2013, Physics in medicine and biology.

[2]  F. Pfeiffer,et al.  Imaging Liver Lesions Using Grating-Based Phase-Contrast Computed Tomography with Bi-Lateral Filter Post-Processing , 2014, PloS one.

[3]  Thilo Michel,et al.  Measurements and simulations analysing the noise behaviour of grating-based X-ray phase-contrast imaging , 2011 .

[4]  H. Graafsma,et al.  LAMBDA — Large Area Medipix3-Based Detector Array , 2012 .

[5]  J. Iwanczyk,et al.  Optimization of room-temperature semiconductor detectors for energy-resolved x-ray imaging , 2011, 2011 IEEE Nuclear Science Symposium Conference Record.

[6]  P. Shikhaliev Energy-resolved computed tomography: first experimental results , 2008, Physics in medicine and biology.

[7]  I. Robinson Elements of Modern X-ray Physics , 2002 .

[8]  Franz Pfeiffer,et al.  Evaluation of the potential of phase-contrast computed tomography for improved visualization of cancerous human liver tissue. , 2013, Zeitschrift fur medizinische Physik.

[9]  Thilo Michel,et al.  Noise in x-ray grating-based phase-contrast imaging. , 2011, Medical physics.

[10]  David M. Paganin,et al.  Coherent X-Ray Optics , 2006 .

[11]  Franz Pfeiffer,et al.  X-ray dark-field and phase-contrast imaging using a grating interferometer , 2009 .

[12]  Michael Campbell,et al.  Grating-based x-ray phase-contrast imaging with a multi energy-channel photon-counting pixel detector. , 2013, Optics express.

[13]  N. Wermes,et al.  A photon counting pixel chip with energy windowing , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[14]  O. Bunk,et al.  Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources , 2006 .

[15]  Guang-Hong Chen,et al.  Quantitative imaging of electron density and effective atomic number using phase contrast CT. , 2010, Physics in medicine and biology.

[16]  O. Bunk,et al.  Tomographic reconstruction of three-dimensional objects from hard X-ray differential phase contrast projection images , 2007 .

[17]  Atsushi Momose,et al.  Phase Tomography by X-ray Talbot Interferometry for Biological Imaging , 2006 .

[18]  Franz Pfeiffer,et al.  Assessment of grating-based X-ray phase-contrast CT for differentiation of invasive ductal carcinoma and ductal carcinoma in situ in an experimental ex vivo set-up , 2013, European Radiology.

[19]  Heinz Graafsma,et al.  The LAMBDA photon-counting pixel detector , 2013 .

[20]  Timm Weitkamp,et al.  Quantitative phase and absorption tomography with an X-ray grating interferometer and synchrotron radiation , 2011 .

[21]  P Thibault,et al.  Unwrapping differential x-ray phase-contrast images through phase estimation from multiple energy data. , 2013, Optics express.

[22]  Michael Campbell,et al.  Medipix3: A 64 k pixel detector readout chip working in single photon counting mode with improved spectrometric performance , 2011 .

[23]  P. Shikhaliev Computed tomography with energy-resolved detection: a feasibility study , 2008, Physics in medicine and biology.

[24]  Gerhard Martens,et al.  Contrast-to-noise in X-ray differential phase contrast imaging , 2011 .

[25]  S. Schleede X-ray Phase-Contrast Imaging at a Compact Laser-Driven Synchrotron Source , 2013 .

[26]  O. Bunk,et al.  Hard-X-ray dark-field imaging using a grating interferometer. , 2008, Nature materials.

[27]  Franz Pfeiffer,et al.  Toward Clinical X-ray Phase-Contrast CT: Demonstration of Enhanced Soft-Tissue Contrast in Human Specimen , 2010, Investigative radiology.

[28]  Franz Pfeiffer,et al.  X-ray phase imaging with a grating interferometer. , 2005, Optics express.

[29]  C. David,et al.  The First Analysis and Clinical Evaluation of Native Breast Tissue Using Differential Phase-Contrast Mammography , 2011, Investigative radiology.

[30]  Heinz Graafsma,et al.  Development of LAMBDA: Large Area Medipix-Based Detector Array , 2011 .

[31]  C. Herrmann,et al.  ChromAIX: Fast photon-counting ASIC for Spectral Computed Tomography , 2011 .

[32]  Michael Campbell,et al.  The Medipix3RX: a high resolution, zero dead-time pixel detector readout chip allowing spectroscopic imaging , 2013 .

[33]  Atsushi Momose,et al.  Demonstration of X-Ray Talbot Interferometry , 2003 .

[34]  Petra Kaufmann,et al.  Two Dimensional Phase Unwrapping Theory Algorithms And Software , 2016 .