Improved rotor current control of wind turbine driven doubly-fed induction generators during network voltage unbalance

Abstract This paper investigates an improved control and operation of a doubly-fed induction generator (DFIG) system under unbalanced network conditions. A new rotor current control scheme is presented, which consists of a main controller and an auxiliary compensator. The main controller is constructed in the same way as the conventional vector control design without involving sequential-component decomposition in order to guarantee system stability and high transient response. While the auxiliary controller is specially designed to control the negative sequence current taking into account the impact of the main controller on negative sequence components. Simulated results on a commercial 1.5-MW DFIG system and experimental tests on a 1.5-kW DFIG prototype are provided and compared with those of conventional vector control and dual PI current control schemes to demonstrate the effectiveness of the proposed control strategy during steady-state and transient conditions when the network voltage is unbalanced.

[1]  N. Mohan,et al.  Control of a Doubly Fed Induction Wind Generator Under Unbalanced Grid Voltage Conditions , 2007, IEEE Transactions on Energy Conversion.

[2]  J. Bendl,et al.  Extended vector control of doubly fed machine under unbalanced power network conditions , 2002 .

[3]  Lie Xu,et al.  Coordinated Control of DFIG's Rotor and Grid Side Converters During Network Unbalance , 2008, IEEE Transactions on Power Electronics.

[4]  H. Akagi,et al.  A new approach to harmonic compensation in power systems , 1988, Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting.

[5]  Jeong-Ik Jang,et al.  Control of Back-to-Back PWM Converters for DFIG Wind Turbine Systems under Unbalanced Grid Voltage , 2007, 2007 IEEE International Symposium on Industrial Electronics.

[6]  He Yikang,et al.  Dynamic modelling and robust current control of wind-turbine driven DFIG during external AC voltage dip , 2006 .

[7]  J.A. Ferreira,et al.  Operation of Grid-Connected DFIG Under Unbalanced Grid Voltage Condition , 2009, IEEE Transactions on Energy Conversion.

[8]  Heng Nian,et al.  Enhanced control of DFIG-used back-to-back PWM VSC under unbalanced grid voltage conditions , 2007 .

[9]  Teodiano Bastos,et al.  SLAM-based robotic wheelchair navigation system designed for confined spaces , 2010, 2010 IEEE International Symposium on Industrial Electronics.

[10]  Lie Xu,et al.  Dynamic Modeling and Control of DFIG-Based Wind Turbines Under Unbalanced Network Conditions , 2007, IEEE Transactions on Power Systems.

[11]  Dong-Choon Lee,et al.  Torque Ripple Elimination for Doubly-Fed Induction Motors under Unbalanced Source Voltage , 2007, 2007 7th International Conference on Power Electronics and Drive Systems.

[12]  Jiabing Hu,et al.  Modeling and enhanced control of DFIG under unbalanced grid voltage conditions , 2009 .