Development of a wireless blood pressure measuring device with smart mobile device

Today, smart mobile devices (telephones and tablets) are very commonly used due to their powerful hardware and useful features. According to an eMarketer report, in 2014 there were 1.76 billion smartphone users (excluding users of tablets) in the world; it is predicted that this number will rise by 15.9% to 2.04 billion in 2015. It is thought that these devices can be used successfully in biomedical applications. A wireless blood pressure measuring device used together with a smart mobile device was developed in this study. By means of an interface developed for smart mobile devices with Android and iOS operating systems, a smart mobile device was used both as an indicator and as a control device. The cuff communicating with this device through Bluetooth was designed to measure blood pressure via the arm. A digital filter was used on the cuff instead of the traditional analog signal processing and filtering circuit. The newly developed blood pressure measuring device was tested on 18 patients and 20 healthy individuals of different ages under a physician's supervision. When the test results were compared with the measurements made using a sphygmomanometer, it was shown that an average 93.52% accuracy in sick individuals and 94.53% accuracy in healthy individuals could be achieved with the new device.

[1]  Chun-Chieh Hsiao,et al.  A Mobile-Care System Integrated with Bluetooth Blood Pressure and Pulse Monitor, and Cellular Phone , 2006, IEICE Trans. Inf. Syst..

[2]  J. Moraes,et al.  Development of a new oscillometric blood pressure measurement system , 1999, Computers in Cardiology 1999. Vol.26 (Cat. No.99CH37004).

[3]  A comparison of blood pressure and pulse pressure values obtained by oscillometric and central measurements in hypertensive patients , 2010, Blood pressure.

[4]  Charles F Babbs,et al.  Oscillometric measurement of systolic and diastolic blood pressures validated in a physiologic mathematical model , 2012, Biomedical engineering online.

[6]  F. Segura-Quijano,et al.  Design and implementation of a wireless tensiometer with smartphone interface , 2013, 2013 Pan American Health Care Exchanges (PAHCE).

[7]  R. Fuentes,et al.  DIGITAL BLOOD PRESSURE MONITOR , 2009 .

[8]  Michael Böhm,et al.  2013 ESH/ESC Guidelines for the management of arterial hypertension: the Task Force for the management of arterial hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC). , 2007, Journal of hypertension.

[9]  Wan-Young Chung,et al.  A Smartphone-Based Driver Safety Monitoring System Using Data Fusion , 2012, Sensors.

[10]  A. Dominiczak,et al.  2007 Guidelines for the Management of Arterial Hypertension: The Task Force for the Management of Arterial Hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC) , 2007, European heart journal.

[11]  E. O’Brien,et al.  An outline of the revised British Hypertension Society protocol for the evaluation of blood pressure measuring devices. , 1993, Journal of hypertension.

[12]  Yuan-Hsiang Lin,et al.  Bluetooth Low Energy (BLE) based blood pressure monitoring system , 2014, 2014 International Conference on Intelligent Green Building and Smart Grid (IGBSG).

[13]  Hilmi R. Dajani,et al.  Oscillometric Blood Pressure Estimation: Past, Present, and Future , 2015, IEEE Reviews in Biomedical Engineering.

[14]  L. A. Geddes,et al.  Handbook of Blood Pressure Measurement , 1991 .

[15]  James McNames,et al.  Optimal Filter Design to Compute the Mean of Cardiovascular Pressure Signals , 2008, IEEE Transactions on Biomedical Engineering.

[16]  Ram Dantu,et al.  Cuffless Differential Blood Pressure Estimation Using Smart Phones , 2013, IEEE Transactions on Biomedical Engineering.

[17]  Aniruddha Sinha,et al.  Smart phone based blood pressure indicator , 2014, MobileHealth '14.

[18]  Pedro Silva,et al.  A pervasive system for real-time blood pressure monitoring , 2013 .

[19]  Carlos Arteta,et al.  Low-Cost Blood Pressure Monitor Device for Developing Countries , 2011, MobiHealth.

[20]  Mengsun Yu,et al.  Noninvasive measurement of beat-to-beat arterial blood pressure by the Korotkoff sound delay time , 2012, Blood pressure monitoring.

[21]  Yutaka Imai,et al.  European Society of Hypertension International Protocol revision 2010 for the validation of blood pressure measuring devices in adults , 2010, Blood pressure monitoring.