Drop size distribution measured by imaging: determination of the measurement volume by the calibration of the point spread function

Measurement of drop size distributions in a spray depends on the definition of the control volume for drop counting. For image-based techniques, this implies the definition of a depth-of-field (DOF) criterion. A sizing procedure based on an imaging model and associated with a calibration procedure is presented. Relations between image parameters and object properties are used to provide a measure of the size of the droplets, whatever the distance from the in-focus plane. A DOF criterion independent of the size of the drops and based on the determination of the width of the point spread function (PSF) is proposed. It allows to extend the measurement volume to defocused droplets and, due to the calibration of the PSF, to clearly define the depth of the measurement volume. Calibrated opaque discs, calibrated pinholes and an optical edge are used for this calibration. A comparison of the technique with a phase Doppler particle analyser and a laser diffraction granulometer is performed on an application to an industrial spray. Good agreement is found between the techniques when particular care is given to the sampling of droplets. The determination of the measurement volume is used to determine the drop concentration in the spray and the maximum drop concentration that imaging can support.

[1]  D. Lebrun,et al.  Methods for the deconvolution of defocused-image pairs recorded separately on two CCD cameras: application to particle sizing. , 1996, Applied optics.

[2]  L G Dodge,et al.  Drop-size measurement techniques for sprays: comparison of Malvern laser-diffraction and Aerometrics phase/Doppler. , 1987, Applied optics.

[3]  Michel P. Bonin,et al.  Laser-based techniques for particle-size measurement: A review of sizing methods and their industrial applications , 1996 .

[4]  Geoffrey Dougherty,et al.  The point spread function revisited: image restoration using 2-D deconvolution , 2001 .

[5]  J. Shrimpton,et al.  Two‐Phase Flow Characterization by Automated Digital Image Analysis. Part 1: Fundamental Principles and Calibration of the Technique , 2003 .

[6]  D. Lebrun,et al.  On the measurements of particles by imaging methods: Theoretical and Experimental Aspects , 1996 .

[7]  Antonio Lecuona,et al.  Volumetric characterization of dispersed two-phase flows by digital image analysis , 2000 .

[8]  Norman Chigier,et al.  Optical imaging of sprays , 1991 .

[9]  J. Goodman Introduction to Fourier optics , 1969 .

[10]  Sang Yong Lee,et al.  Determination of in-focus criteria and depth of field in image processing of spray particles , 2001 .

[11]  R. Adrian Particle-Imaging Techniques for Experimental Fluid Mechanics , 1991 .

[12]  G Dougherty Effect of sub-pixel misregistration on the determination of the point spread function of a CT imaging system. , 2000, Medical engineering & physics.

[13]  J. Blaisot,et al.  Droplet Size Distribution and Sphericity Measurements of Low‐Density Sprays Through Image Analysis , 2000 .

[14]  Koichi Nishino,et al.  Stereo imaging for simultaneous measurement of size and velocity of particles in dispersed two-phase flow , 2000 .

[15]  A. Tonazzini,et al.  Drop size distribution in sprays by image processing , 1990 .

[16]  Sang Yong Lee,et al.  Sizing of spray particles using image processing technique , 2004 .

[17]  J. Blaisot,et al.  Droplet size and morphology characterization for dense sprays by image processing: application to the Diesel spray , 2005 .

[18]  Steven A. Shafer,et al.  Depth from focusing and defocusing , 1993, Proceedings of IEEE Conference on Computer Vision and Pattern Recognition.

[19]  F. Durst,et al.  Particle trajectory effects in phase Doppler systems: computations and experiments , 1993 .

[20]  Alex Pentland,et al.  A New Sense for Depth of Field , 1985, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[21]  G. Cho,et al.  Determination of point spread function for a flat-panel X-ray imager and its application in image restoration , 2006 .

[22]  J. Fabre,et al.  Sizing of bubbles by incoherent imaging: defocus bias , 1997 .

[23]  Franz Durst,et al.  Trajectory Ambiguities in Phase Doppler Systems: Study of a near forward and a near‐backward geometry , 1994 .

[24]  R. Crane,et al.  A simple off-line automatic image analysis system with application to drop sizing in two-phase flows , 1980 .

[25]  Sung Soo Kim,et al.  Drop Sizing and Depth-of-Field Correction in TV Imaging , 1994 .