A Device Reactive Capability Assessment Model Based on Improving Voltage Stability L Indicator

Taking advantage of improving voltage stability L indicator, voltage level, active power loss to assess device reactive capability in overload situations. Considering the intermediate buses which connect the generator bus and load bus, the compound buses which involve the two types of buses, improving voltage stability L indicator is proposed. So device reactive capability could be calculated. The example shows the best reactive device is generator, and the second one is capacitor bank and the last one is transformer tap. Assessment of reactive device capability is beneficial and practical for operation stuff to take appropriate measures in order to transfer overload situations into normal state.

[1]  C. Reis,et al.  A comparison of voltage stability indices , 2006, MELECON 2006 - 2006 IEEE Mediterranean Electrotechnical Conference.

[2]  T. L. Crawley Validation of generator reactive capability , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[3]  Jia Hong-jie Optimal Power Flow with Voltage Stability Constraint Based on L Index , 2006 .

[4]  Zhou Shuang REVIEW ON STEADY STATE VOLTAGE STABILITY INDICES OF POWER SYSTEMS , 2001 .

[5]  An Ning,et al.  Power System Voltage Stability Limits Estimation based on Quasi-Steady-State Simulation , 2006, 2006 International Conference on Power System Technology.

[6]  Conversion and delivery of electrical energy in the 21st century , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[7]  D.O. Dike,et al.  Utilization of L-index in microgrid interconnected power system network , 2008, 2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century.

[8]  Li Hua-qiang Regional power system reactive power capability based on voltage stability , 2009 .

[9]  M. M. Adibi,et al.  Reactive capability limitation of synchronous machines , 1994 .

[10]  Wang Wei Reduced Jacobian Matrix Based Method to Assess Local Static Reactive Power/Voltage Supporting Ability of Interconnected Wind Farm , 2009 .

[11]  H. Glavitsch,et al.  Estimating the Voltage Stability of a Power System , 1986, IEEE Transactions on Power Delivery.

[12]  S. Durairaj,et al.  Improved Genetic Algorithm Approach for Multi-Objective contingency constrained Reactive Power Planning , 2005, 2005 Annual IEEE India Conference - Indicon.