High precision measurements of the 13CO2/12CO2 isotope ratio at atmospheric pressure in human breath using a 2 μm diode laser

A special technique is developed to measure the 13CO2/12CO2 isotope ratio in human breath at atmospheric pressure with a 2 μm tunable diode laser. The procedure used to process the pressure-broadened spectra obtained and calculating the isotope ratio is based on a multidimensional linear regression of the spectra using simulated 13CO2, 12CO2, and H2O spectra. This technique allows the measurement of the δ-value for isotopic ratios with a precision of 0.07‰ within a data acquisition time of 3 min and a long-term reproducibility of 0.2‰.

[1]  Livio Gianfrani,et al.  Diode laser absorption spectrometry for 13CO2/12CO2 isotope ratio analysis: Investigation on precision and accuracy levels , 2005 .

[2]  Philip A. Martin,et al.  An off-axis cavity-enhanced absorption spectrometer at 1605 nm for the 12CO2/13CO2 measurement , 2006 .

[3]  Dirk Richter,et al.  High-precision CO2 isotopologue spectrometer with a difference-frequency-generation laser source. , 2009, Optics letters.

[4]  David D. Nelson,et al.  New method for isotopic ratio measurements of atmospheric carbon dioxide using a 4.3 μm pulsed quantum cascade laser , 2008 .

[5]  R. Restieri,et al.  Chemical and isotopic analysis using diode laser spectroscopy: applications to volcanic gas monitoring , 2002 .

[6]  V. Ochkin Spectroscopy of low temperature plasma , 2009 .

[7]  E. Degens Biogeochemistry of Stable Carbon Isotopes , 1969 .

[8]  Daniele Romanini,et al.  Optical feedback cavity-enhanced absorption spectroscopy for in situ measurements of the ratio 13C:12C in CO2 , 2008 .

[9]  P. Werle,et al.  The limits of signal averaging in atmospheric trace-gas monitoring by tunable diode-laser absorption spectroscopy (TDLAS) , 1993 .

[10]  Ronald K. Hanson,et al.  Measurements of high-pressure CO2 absorption near 2.0 μm and  implications on tunable diode laser sensor design , 2009 .

[11]  Bruce A. Richman,et al.  Applications of cavity ring-down spectroscopy to high precision isotope ratio measurement of 13C/12C in carbon dioxide , 2006, Isotopes in environmental and health studies.

[12]  I. Nikolaev,et al.  Measurement of the concentration ratio for 13Ñ and 12Ñ isotopes at atmospheric pressure by carbon dioxide absorption of diode laser radiation at ~2 μm , 2009 .

[13]  L. Brown,et al.  Self-broadened 12C16O line shapes in the v=2←0 band , 2003 .

[14]  W. Brand,et al.  Stable isotope ratio mass spectrometry in global climate change research , 2003 .

[15]  Livio Gianfrani,et al.  Advances in laser-based isotope ratio measurements: selected applications , 2008 .

[16]  Richard N Zare,et al.  Stable isotope ratios using cavity ring-down spectroscopy: determination of 13C/12C for carbon dioxide in human breath. , 2002, Analytical chemistry.

[17]  Y. Chung,et al.  400 Hz frequency stability of a GaAlAs laser frequency locked to the Rb (D2) line , 1990 .