Wind Turbine PI Controller's Optimization Using PSO Algorithm

A novel technique using particle swarm optimization (PSO) is proposed for optimizing PI parameters controllers of a wind turbine (WT) based on direct drive permanent magnet synchronous generator (DDPMSG). The PSO algorithm is used to search for the optimal combination of PI controllers parameters. A small signal stability (SSS) mode of the WT system is derived to implement PSO algorithm based on eigenvalues analysis as objective function. Simulations are performed to illustrate this control method validity.

[1]  Kit Po Wong,et al.  Optimal controller design of a doubly-fed induction generator wind turbine system for small signal stability enhancement , 2010 .

[2]  L. Wozniak,et al.  Adaptive hydrogenerator governor tuning with a genetic algorithm , 1992 .

[3]  Anis Sakly,et al.  PSO-based MPPT control of wind-driven Self-Excited Induction Generator for pumping system , 2016 .

[4]  James Kennedy,et al.  Particle swarm optimization , 2002, Proceedings of ICNN'95 - International Conference on Neural Networks.

[5]  Xiao-Ping Zhang,et al.  Small signal stability analysis and control of the wind turbine with the direct-drive permanent magnet generator integrated to the grid , 2009 .

[6]  A. Rezaee Jordehi,et al.  Particle swarm optimisation (PSO) for allocation of FACTS devices in electric transmission systems: A review , 2015 .

[7]  Gautam Sarkar,et al.  Performance Comparison between GA and PSO for Optimization of PI and PID controller of Direct FOC Induction Motor Drive , 2012 .

[8]  Lotfi Krichen,et al.  New strategy of pitch angle control for energy management of a wind farm , 2011 .

[9]  M. Rajaram,et al.  Optimal location of FACTS devices using Improved Particle Swarm Optimization , 2013 .

[10]  Ping Ju,et al.  Genetic algorithm aided controller design with application to SVC , 1996 .

[11]  Ayman Attya,et al.  Penetration impact of wind farms equipped with frequency variations ride through algorithm on power system frequency response , 2012 .

[12]  Xiao-Ping Zhang,et al.  Small signal stability analysis and optimal control of a wind turbine with doubly fed induction generator , 2007 .

[13]  S. Kazemlou,et al.  Novel Dynamic Control of Power Systems with Penetration of Renewable Energy Sources in Multi-generator Framework , 2013, 2013 IEEE International Conference on Systems, Man, and Cybernetics.

[14]  Hui Huang,et al.  Small-signal modelling and analysis of wind turbine with direct drive permanent magnet synchronous generator connected to power grid , 2012 .

[15]  S. M. Muyeen,et al.  Small signal stability analysis of doubly fed induction generator including SDBR , 2012, 2012 15th International Conference on Electrical Machines and Systems (ICEMS).