Mechanical deformation of isolated rabbit hearts through passive inflation techniques have been a viable form of replicating heart motion, but its relation to the heart's natural active contractions remain unclear. The mechanical properties of the myocardium may show diverse characteristics while in tension and compression. In this study, epicardial strain was measured with the assistance of computer-aided speckle interferometry (CASI)1. CASI tracks the movement of clusters of particles for measuring epicardial deformation. The heart was cannulated and perfused with Tyrode's solution. Silicon carbide particles were applied onto the myocardium to form random speckle pattern images while the heart was allowed to actively contract and stabilize. High resolution videos (1000x1000 pixels) of the left ventricle were taken with a complementary metal oxide semiconductor (CMOS) camera as the heart was actively contracting through electrical pacing at various cycle lengths between 250-800 ms. A latex balloon was then inserted into the left ventricle via left atrium and videos were taken as the balloon was repeatedly inflated and deflated at controlled volumes (1-3 ml/cycle). The videos were broken down into frames and analyzed through CASI. Active contractions resulted in non-uniform circular epicardial and uniaxial contractions at different stages of the motion. In contrast, the passive heart demonstrated very uniform expansion and contraction originating from the source of the latex balloon. The motion of the active heart caused variations in deformation, but in comparison to the passive heart, had a more enigmatic displacement field. The active heart demonstrated areas of large displacement and others with relatively no displacement. Application of CASI was able to successfully distinguish the motions between the active and passive hearts.
[1]
Y Zeng,et al.
A comparison of biomechanical properties between human and porcine cornea.
,
2001,
Journal of biomechanics.
[2]
D. R. Veronda,et al.
Mechanical characterization of skin-finite deformations.
,
1970,
Journal of biomechanics.
[3]
Fu-Pen Chiang,et al.
Computer Aided Speckle Interferometry: A Technique for Measuring Deformation of the Surface of the Heart
,
2001,
Annals of Biomedical Engineering.
[4]
Clinton T. Rubin,et al.
Regulation of bone mass by mechanical strain magnitude
,
1985,
Calcified Tissue International.
[5]
Hideki Hayashi,et al.
Effects of Cytochalasin D on Electrical Restitution and the Dynamics of Ventricular Fibrillation in Isolated Rabbit Heart
,
2003,
Journal of cardiovascular electrophysiology.
[6]
Robert W. Mills,et al.
Ventricular Filling Slows Epicardial Conduction and Increases Action Potential Duration in an Optical Mapping Study of the Isolated Rabbit Heart
,
2003,
Journal of cardiovascular electrophysiology.
[7]
Y. Fung,et al.
Biomechanics: Mechanical Properties of Living Tissues
,
1981
.
[8]
M. Sato.
[Mechanical properties of living tissues].
,
1986,
Iyo denshi to seitai kogaku. Japanese journal of medical electronics and biological engineering.
[9]
Fu-Pen Chiang,et al.
Effects of ischemia on epicardial deformation in the passive rabbit heart.
,
2004,
Journal of biomechanical engineering.