Real-time segmentation of burst suppression patterns in critical care EEG monitoring

OBJECTIVE Develop a real-time algorithm to automatically discriminate suppressions from non-suppressions (bursts) in electroencephalograms of critically ill adult patients. METHODS A real-time method for segmenting adult ICU EEG data into bursts and suppressions is presented based on thresholding local voltage variance. Results are validated against manual segmentations by two experienced human electroencephalographers. We compare inter-rater agreement between manual EEG segmentations by experts with inter-rater agreement between human vs automatic segmentations, and investigate the robustness of segmentation quality to variations in algorithm parameter settings. We further compare the results of using these segmentations as input for calculating the burst suppression probability (BSP), a continuous measure of depth-of-suppression. RESULTS Automated segmentation was comparable to manual segmentation, i.e. algorithm-vs-human agreement was comparable to human-vs-human agreement, as judged by comparing raw EEG segmentations or the derived BSP signals. Results were robust to modest variations in algorithm parameter settings. CONCLUSIONS Our automated method satisfactorily segments burst suppression data across a wide range adult ICU EEG patterns. Performance is comparable to or exceeds that of manual segmentation by human electroencephalographers. SIGNIFICANCE Automated segmentation of burst suppression EEG patterns is an essential component of quantitative brain activity monitoring in critically ill and anesthetized adults. The segmentations produced by our algorithm provide a basis for accurate tracking of suppression depth.

[1]  E. Niedermeyer,et al.  The Burst-Suppression Electroencephalogram , 2009, Clinical EEG.

[2]  Herbert Witte,et al.  Use of adaptive hilbert transformation for EEG segmentation and calculation of instantaneous respiration rate in neonates , 2005, Journal of Clinical Monitoring.

[3]  G. B. Young,et al.  Prognostic Determination in Anoxic-Ischemic and Traumatic Encephalopathies , 2004, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[4]  E. Brown,et al.  General anesthesia and altered states of arousal: a systems neuroscience analysis. , 2011, Annual review of neuroscience.

[5]  Tapio Seppänen,et al.  Automatic Analysis and Monitoring of Burst Suppression in Anesthesia , 2002, Journal of Clinical Monitoring and Computing.

[6]  Emery N. Brown,et al.  A state-space model of the burst suppression ratio , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  C. Thomsen,et al.  Assessment of anaesthetic depth by clustering analysis and autoregressive modelling of electroencephalograms. , 1991, Computer methods and programs in biomedicine.

[8]  Françoise Masson,et al.  The Use of Bispectral Index to Monitor Barbiturate Coma in Severely Brain-Injured Patients with Refractory Intracranial Hypertension , 2008, Anesthesia and analgesia.

[9]  A. J. Derbyshire,et al.  THE EFFECTS OF ANESTHETICS ON ACTION POTENTIALS IN THE CEREBRAL CORTEX OF THE CAT , 1936 .

[10]  C. W. Watson,et al.  Effects of barbiturates and ether on spontaneous electrical activity of dog brain. , 1949, Journal of neurophysiology.

[11]  Florin Amzica,et al.  Basic physiology of burst‐suppression , 2009, Epilepsia.

[12]  G. Guiraudon,et al.  Pharmacologic EEG Suppression during Cardiopulmonary Bypass: Cerebral Hemodynamic and Metabolic Effects of Thiopental or Isoflurane during Hypothermia and Normothermia , 1987, Anesthesiology.

[13]  Terrence J. Sejnowski,et al.  Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysis , 2007, NeuroImage.

[14]  Jean Carletta,et al.  Assessing Agreement on Classification Tasks: The Kappa Statistic , 1996, CL.

[15]  M. Nunes,et al.  Prognostic value of non-reactive burst suppression EEG pattern associated to early neonatal seizures. , 2005, Arquivos de neuro-psiquiatria.

[16]  I J Rampil,et al.  No correlation between quantitative electroencephalographic measurements and movement response to noxious stimuli during isoflurane anesthesia in rats. , 1992, Anesthesiology.

[17]  William O Tatum,et al.  Artifact and Recording Concepts in EEG , 2011, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[18]  G. Fraser,et al.  Comparing the Bispectral Index and Suppression Ratio with Burst Suppression of the Electroencephalogram During Pentobarbital Infusions in Adult Intensive Care Patients , 2003, Pharmacotherapy.

[19]  P C Vijn,et al.  I.v. anaesthesia and EEG burst suppression in rats: bolus injections and closed-loop infusions. , 1998, British journal of anaesthesia.

[20]  Richard P Brenner,et al.  The Interpretation of the EEG in Stupor and Coma , 2005, The neurologist.

[21]  C. Binnie,et al.  A glossary of terms most commonly used by clinical electroencephalographers. , 1974, Electroencephalography and clinical neurophysiology.

[22]  Michel J. A. M. van Putten,et al.  Continuous electroencephalography monitoring for early prediction of neurological outcome in postanoxic patients after cardiac arrest: A prospective cohort study* , 2012, Critical care medicine.

[23]  N. Thakor,et al.  Detecting EEG bursts after hypoxic-ischemic injury using energy operators , 1997, Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136).

[24]  M. Blennow,et al.  The prognostic value of early aEEG in asphyxiated infants undergoing systemic hypothermia treatment , 2010, Acta paediatrica.

[25]  ShiNung Ching,et al.  Burst suppression probability algorithms: state-space methods for tracking EEG burst suppression , 2013, Journal of neural engineering.

[26]  G. B. Young,et al.  The EEG in Coma , 2000, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[27]  Paul A. Viola,et al.  Robust Real-Time Face Detection , 2001, International Journal of Computer Vision.

[28]  Serge Vulliémoz,et al.  A Randomized Trial for the Treatment of Refractory Status Epilepticus , 2011, Neurocritical care.

[29]  Nitish V. Thakor,et al.  EEG burst detection: performance evaluation , 1999, Proceedings of the First Joint BMES/EMBS Conference. 1999 IEEE Engineering in Medicine and Biology 21st Annual Conference and the 1999 Annual Fall Meeting of the Biomedical Engineering Society (Cat. N.

[30]  H. Witte,et al.  New Approaches for the Detection and Analysis of Electroencephalographic Burst-Suppression Patterns in Patients under Sedation , 1999, Journal of Clinical Monitoring and Computing.

[31]  A. Yli-Hankala,et al.  Adaptive segmentation of burst-suppression pattern in isoflurane and enflurane anesthesia , 1995, International journal of clinical monitoring and computing.

[32]  Esa Mervaala,et al.  Can BIS monitoring be used to assess the depth of propofol anesthesia in the treatment of refractory status epilepticus? , 2010, Epilepsia.

[33]  Y. Istefanopulos,et al.  IEEE Engineering in Medicine and Biology Society , 2019, IEEE Transactions on Biomedical Engineering.

[34]  Herbert Witte,et al.  Common Optimization of Adaptive Preprocessing Units and a Neural Network during the Learning Period. Application in EEG Pattern Recognition , 1997, Neural Networks.

[35]  B. Matta,et al.  Burst suppression or isoelectric encephalogram for cerebral protection: evidence from metabolic suppression studies. , 1999, British journal of anaesthesia.

[36]  Emery N Brown,et al.  A neurophysiological–metabolic model for burst suppression , 2012, Proceedings of the National Academy of Sciences.

[37]  Nitish V. Thakor,et al.  Application of Tsallis Entropy to EEG: Quantifying the Presence of Burst Suppression After Asphyxial Cardiac Arrest in Rats , 2010, IEEE Transactions on Biomedical Engineering.

[38]  Matthias Schwab,et al.  Making scientific computations reproducible , 2000, Comput. Sci. Eng..

[39]  F. Babiloni,et al.  Removal of ocular artifacts for high resolution EEG studies: a simulation study , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[40]  R. Ramsay Treatment of Status Epilepticus , 1993, Epilepsia.

[41]  Robert Gentleman,et al.  Reproducible Research: A Bioinformatics Case Study , 2005, Statistical applications in genetics and molecular biology.

[42]  S. Haykin,et al.  Adaptive Filter Theory , 1986 .